HLW flowsheet material balance for DWPF rad operation with Tank 51 sludge and ITP Cycle 1 precipitate (open access)

HLW flowsheet material balance for DWPF rad operation with Tank 51 sludge and ITP Cycle 1 precipitate

This document presents the details of the Savannah River Plant Flowsheet for the Rad Operation with Tank Sludge and ITP Cycle 1 Precipitate. Topics discussed include: material balance; radiolysis chemistry of tank precipitates; algorithm for ESP washing; chemistry of hydrogen and ammonia generation in CPC; batch sizes for processing feed; and total throughput of a streams during one cycle of operation.
Date: April 19, 1995
Creator: Choi, A.S.
Object Type: Report
System: The UNT Digital Library
SRTC Monthly Report December 1994 (open access)

SRTC Monthly Report December 1994

This is the Savannah River Technology Center monthly report for December 1994.
Date: April 19, 1995
Creator: Ferrell, J.M.
Object Type: Report
System: The UNT Digital Library
Photographic as-builts for Argonne National Laboratory-West (open access)

Photographic as-builts for Argonne National Laboratory-West

Located 35 miles West of Idaho Falls, Idaho, Argonne National Laboratory-West operates a number of nuclear facilities for the Department of Energy (DOE) through the University of Chicago. Part of the present mission of Argonne National Laboratory-West includes shutdown of the EBR-II Reactor. In order to accomplish this task the Engineering-Drafting Department is exploring cost effective methods of providing as-building services. A new technology of integrating photographic images and AUTOCAD drawing files is considered one of those methods that shows promise.
Date: April 19, 1995
Creator: Sherman, E. K. & Wiegand, C. V.
Object Type: Article
System: The UNT Digital Library
Accelerated test methods for life prediction of hermetic motor insulation systems exposed to alternative refrigerant/lubricant mixtures. Final report (open access)

Accelerated test methods for life prediction of hermetic motor insulation systems exposed to alternative refrigerant/lubricant mixtures. Final report

In 1992, the Air-Conditioning and Refrigeration Technology Institute, Inc. (ARTI) contracted Radian Corporation to ascertain whether an improved accelerated test method or procedure could be developed that would allow prediction of the life of motor insulation materials used in hermetic motors for air-conditioning and refrigeration equipment operated with alternative refrigerant/lubricant mixtures. Phase 1 of the project, Conceptual Design of an accelerated test method and apparatus, was successfully completed in June 1993. The culmination of that effort was the concept of the Simulated Stator Unit (SSU) test. The objective of the Phase 2 limited proof-of-concept demonstration was to: answer specific engineering/design questions; design and construct an analog control sequencer and supporting apparatus; and conduct limited tests to determine the viability of the SSU test concept. This report reviews the SSU test concept, and describes the results through the conclusion of the proof-of-concept prototype tests in March 1995. The technical design issues inherent in transforming any conceptual design to working equipment have been resolved, and two test systems and controllers have been constructed. Pilot tests and three prototype tests have been completed, concluding the current phase of work. One prototype unit was tested without thermal stress loads. Twice daily insulation property measurements …
Date: April 19, 1995
Creator: Ellis, P. F., II & Ferguson, A. F.
Object Type: Report
System: The UNT Digital Library
Functions and requirements for Hanford single-shell tank leakage detection and monitoring (open access)

Functions and requirements for Hanford single-shell tank leakage detection and monitoring

This document provides the initial functions and requirements for leakage detection and monitoring applicable to past and potential future leakage from the Hanford Site`s 149 single-shell high-level waste tanks. This mission is a part of the overall mission of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineering principles are being applied to this effort. This document reflects the an initial step in the systems engineering approach to decompose the mission into primary functions and requirements. The document is considered approximately 30% complete relative to the effort required to produce a final version that can be used to support demonstration and/or procurement of technologies. The functions and requirements in this document apply to detection and monitoring of below ground leaks from SST containment boundaries and the resulting soil contamination. Leakage detection and monitoring is invoked in the TWRS Program in three fourth level functions: (1) Store Waste, (2) Retrieve Waste, and (3) Disposition Excess Facilities (as identified in DOE/RL-92-60 Rev. 1, Tank Waste Remediation System Functions and Requirements).
Date: April 19, 1995
Creator: Cruse, J.M. & Ohl, P.C.
Object Type: Report
System: The UNT Digital Library
Interim cryo-cooler/detector report (open access)

Interim cryo-cooler/detector report

This report describes development of an electronic system designed to reduce vibration generated by a cryocooler. The diminished vibration makes it practical to use the active cooler to extract heat from a portable gamma ray detector instrument. The system was developed for a Sunpower cryocooler with an integrated counterbalance mass. The overall momentum cancellation approach is also applicable to other similar cryocoolers. The cancellation system is an assembly of several components tailored to accomplish the required vibration reduction with minimum power consumption and volume. It is designed to be powered by a 18--32 Volt battery. Up to ten harmonics of the 58.65 Hz drive frequency are controlled. In addition to the vibration cancellation, the electronic system produces the drive signal for the cryocooler and regulates the cooler temperature. The system employs a sinusoidal drive to reduce the amount of higher harmonic vibration. A digital signal processor (DSP) is used to perform the high speed vibration control. The Texas Instruments TMS320C31 processor is housed on a third-party board. A second board has analog-to-digital (A/D) and digital-to-analog (D/A) converters. The DSP was programmed in C. The physical system consists of two sets of electronics. The first is housed in a case that …
Date: April 19, 1995
Creator: Neufeld, K.; Ruhter, W. & Anderson, E.
Object Type: Report
System: The UNT Digital Library