Development of alternative oxygen production source using a zirconia solid electrolyte membrane (open access)

Development of alternative oxygen production source using a zirconia solid electrolyte membrane

The objective of this multiyear effort was the development, fabrication and testing of a zirconia oxygen production module capable of delivering approximately 100 liters/minute (LPM) of oxygen. The work discussed in this report consists of development and improvement of the zirconia cell along with manufacture of cell components, preliminary design of the final plant, additional economic analysis and industrial participation. (VC)
Date: August 1, 1990
Creator: Suitor, J. W.; Clark, D. J. & Losey, R. W.
Object Type: Report
System: The UNT Digital Library
Development of alternative oxygen production source using a zirconia solid electrolyte membrane. Final report (open access)

Development of alternative oxygen production source using a zirconia solid electrolyte membrane. Final report

The objective of this multiyear effort was the development, fabrication and testing of a zirconia oxygen production module capable of delivering approximately 100 liters/minute (LPM) of oxygen. The work discussed in this report consists of development and improvement of the zirconia cell along with manufacture of cell components, preliminary design of the final plant, additional economic analysis and industrial participation. (VC)
Date: August 1, 1990
Creator: Suitor, J. W.; Clark, D. J. & Losey, R. W.
Object Type: Report
System: The UNT Digital Library
Design considerations for a fiber optic communications network for power systems (open access)

Design considerations for a fiber optic communications network for power systems

The design of a fiber optic communication network for monitoring and control in power systems is discussed. It is shown that by appropriate choice of protocols, a fault-tolerant system can be built that operates in any arbitrary configuration. Since the network is based on fiber optics, it can be made fast enough for substation monitoring and control. In this application, a relatively small number of cables is required to implement a high reliability system. The network can also be used for distribution automation. In this application the network is required to reach all parts of the power system, and the fiber cable itself becomes a significant fraction of the cost of communications. However, since many applications can be supported at once, the cost per function can be reasonable.
Date: August 1, 1993
Creator: Kirkham, H.; Johnston, A. R. & Allen, G. D.
Object Type: Article
System: The UNT Digital Library