Final report -- PT-105-514-A, Installation of thermocouples in process channels (open access)

Final report -- PT-105-514-A, Installation of thermocouples in process channels

This document discusses a production test which was written when the piles were operating under a graphite temperature limit of 410 C. Operation was controlled by as-read temperatures of the originally installed G thermocouples, by thermocouples installed on vertical safety rod thimbles, and by thermocouples in graphite cylinders installed in the C test holes. Since the thimble thermocouples were to be removed under the Ball 3X program, it was planned to install thermocouples in some of the process tube channels to help monitor the graphite temperatures. In order to ensure maximum production levels based on graphite temperatures, the proper temperature relationships between the channel thermocouples and the G and/or C test hole thermocouples were needed. The expected maximum allowable channel thermocouple temperature reading would be higher than the burnout temperature limit of the graphite in the-pile.
Date: August 8, 1955
Creator: Greenfield, H. H.
System: The UNT Digital Library