Real-time Studies of Shocked Polycrystalline Materials with Single-Pulse X-ray Diffraction (open access)

Real-time Studies of Shocked Polycrystalline Materials with Single-Pulse X-ray Diffraction

Characteristic K-α x-rays used for single-pulse XRD are conventionally produced by a 37-stage high-voltage Marx pulse generator coupled to a vacuum needle-and-washer x-ray diode via coaxial transmission line. A large field-of-view x-ray image plate detection system typically enables observation of several Debye-Scherrer rings. Recently, we have developed a fiber-optic reducer, coupled to a CCD camera, to obtain low-noise, large field-of-view images. The direct beam spot is produced by bremsstrahlung radiation attenuated by a twomillimeter tungsten beam stop. Determination of the direct beam position is necessary to perform the ring integration.
Date: May 25, 2011
Creator: Morgan, Dane V.
Object Type: Article
System: The UNT Digital Library
Annual Report of Monitoring at Barnes, Kansas, in 2010 (open access)

Annual Report of Monitoring at Barnes, Kansas, in 2010

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at Barnes, Kansas, in 1949-1974. Carbon tetrachloride contamination was initially detected in 1986 in the town's public water supply wells. In 2006-2007, the CCC/USDA conducted a comprehensive targeted investigation at and near its former property in Barnes to characterize this contamination. Those results were reported previously (Argonne 2008a). The results of that investigation indicated that carbon tetrachloride contamination is present in groundwater at low to moderate levels in the vicinity of the former CCC/USDA grain storage facility. Information obtained during the 2006-2007 investigation also indicated that at least one other potential source might have contributed to the groundwater contaminant plume (Argonne 2008a). The former agriculture building owned by the local school district, located immediately east of well PWS3, is also a potential source of the contamination. In November 2007, the CCC/USDA began periodic groundwater monitoring at Barnes. The monitoring is being conducted on behalf of the CCC/USDA by Argonne National Laboratory, under the direction of the Kansas Department of Health and Environment (KDHE). The objective is to monitor the carbon tetrachloride contamination identified in the groundwater at Barnes. Through 2010, sampling was conducted in …
Date: May 25, 2011
Creator: LaFreniere, L. M.
Object Type: Report
System: The UNT Digital Library
Final Scientific Report (open access)

Final Scientific Report

Hackensack University Medical Center's major initiative to create a cleaner healthier and safer environment for patients, employees and the community served by the medical center is built on its commitment to protect the environment and conserve precious energy resources. Since 2004 the Medical Center launched a long term campaign to temper the negative environmental impact of proposed and existing new construction at the medical center and to improve campus wide overall energy efficiency. The plan was to begin by implementing a number of innovative and eco-friendly enhancements to the Gabrellian Women's and Children's Pavilion, in construction at the time, which would lead to Certification by the US Green Building Councils Leadership & Environmental Design (LEED) program. In addition the medical center would evaluate the feasibility of implementing a photovoltaic system in the new construction (in development and planned) to provide clean pollution free electricity. The steps taken to achieve this included conducting a feasibility study complete with architectural and engineering assessments to determine the potential for implementation of a photovoltaic system on the campus and also to conduct an energy survey that would focus on determining specific opportunities and upgrades that would lead to a healthier energy efficient interior environment …
Date: May 25, 2011
Creator: Lutwick, Suzanne & Cunning, Helen
Object Type: Report
System: The UNT Digital Library
Optimization of Operating Parameters for Minimum Mechanical Specific Energy in Drilling (open access)

Optimization of Operating Parameters for Minimum Mechanical Specific Energy in Drilling

Efficiency in drilling is measured by Mechanical Specific Energy (MSE). MSE is the measure of the amount of energy input required to remove a unit volume of rock, expressed in units of energy input divided by volume removed. It can be expressed mathematically in terms of controllable parameters; Weight on Bit, Torque, Rate of Penetration, and RPM. It is well documented that minimizing MSE by optimizing controllable factors results in maximum Rate of Penetration. Current methods for computing MSE make it possible to minimize MSE in the field only through a trial-and-error process. This work makes it possible to compute the optimum drilling parameters that result in minimum MSE. The parameters that have been traditionally used to compute MSE are interdependent. Mathematical relationships between the parameters were established, and the conventional MSE equation was rewritten in terms of a single parameter, Weight on Bit, establishing a form that can be minimized mathematically. Once the optimum Weight on Bit was determined, the interdependent relationship that Weight on Bit has with Torque and Penetration per Revolution was used to determine optimum values for those parameters for a given drilling situation. The improved method was validated through laboratory experimentation and analysis of published …
Date: May 25, 2011
Creator: Hamrick, Todd
Object Type: Thesis or Dissertation
System: The UNT Digital Library
SPS Ecloud Instabilities - Analysis of Machine Studies and Implications for Ecloud Feedback (open access)

SPS Ecloud Instabilities - Analysis of Machine Studies and Implications for Ecloud Feedback

The SPS at high intensities exhibits transverse single bunch instabilities with signatures consistent with an Ecloud driven instability. We present recent MD data from the SPS, details of the instrument technique and spectral analysis methods which help reveal complex vertical motion that develops within a subset of the injected bunch trains. The beam motion is detected via wideband exponential taper striplines and delta-sigma hybrids. The raw sum and difference data is sampled at 50 GHz with 1.8 GHz bandwidth. Sliding window FFT techniques and RMS motion techniques show the development of large vertical tune shifts on portions of the bunch of nearly 0.025 from the base tune of 0.185. Results are presented via spectrograms and bunch slice trajectories to illustrate development of the unstable beam and time scale of development along the injected bunch train. The study shows that the growing unstable motion occupies a very broad frequency band of 1.2 GHz. These measurements are compared to numerical simulation results, and the system parameter implications for an Ecloud feedback system are outlined.
Date: May 25, 2011
Creator: Fox, J.; Bullitt, A.; Mastorides, T.; Ndabashimiye, G.; Rivetta, C. H.; Turgut, O. et al.
Object Type: Article
System: The UNT Digital Library
Using Cool Roofs to Reduce Energy Use, Greenhouse Gas Emissions, and Urban Heat-island Effects: Findings from an India Experiment (open access)

Using Cool Roofs to Reduce Energy Use, Greenhouse Gas Emissions, and Urban Heat-island Effects: Findings from an India Experiment

Cool roofs, cool pavements, and urban vegetation reduce energy use in buildings, lower local air pollutant concentrations, and decrease greenhouse gas emissions from urban areas. This report summarizes the results of a detailed monitoring project in India and related simulations of meteorology and air quality in three developing countries. The field results quantified direct energy savings from installation of cool roofs on individual commercial buildings. The measured annual energy savings potential from roof-whitening of previously black roofs ranged from 20-22 kWh/m2 of roof area, corresponding to an air-conditioning energy use reduction of 14-26% in commercial buildings. The study estimated that typical annual savings of 13-14 kWh/m2 of roof area could be achieved by applying white coating to uncoated concrete roofs on commercial buildings in the Metropolitan Hyderabad region, corresponding to cooling energy savings of 10-19%. With the assumption of an annual increase of 100,000 square meters of new roof construction for the next 10 years in the Metropolitan Hyderabad region, the annual cooling energy savings due to whitening concrete roof would be 13-14 GWh of electricity in year ten alone, with cumulative 10-year cooling energy savings of 73-79 GWh for the region. The estimated savings for the entire country would …
Date: May 25, 2011
Creator: Akbari, Hashem; Xu, Tengfang; Taha, Haider; Wray, Craig; Sathaye, Jayant; Garg, Vishal et al.
Object Type: Report
System: The UNT Digital Library
Nuclear Nonproliferation and Arms Control Primer Prepared for the Blue Ribbon Commission on America’s Nuclear Future (open access)

Nuclear Nonproliferation and Arms Control Primer Prepared for the Blue Ribbon Commission on America’s Nuclear Future

To provide a brief overview of key arms control and nonproliferation arrangements for the layperson that may be relevant to the Commission's comprehensive review of policies for managing the back end of the nuclear fuel cycle. Primer would be published by the Commission and made publicly available, probably as an appendix to a larger Commission report.
Date: May 25, 2011
Creator: Williams, Laura S.
Object Type: Report
System: The UNT Digital Library
B Lifetimes and X,Y,Z States at the Tevatron (open access)

B Lifetimes and X,Y,Z States at the Tevatron

A measurement of b-hadron lifetimes in the fully reconstructed decay modes B{sup +} {yields} J/{psi}K{sup +}, B{sup 0} {yields} J/{psi}K*{sup 0}, B{sup 0} {yields} J/{psi}K{sub S}{sup 0}, and {Lambda}{sub b}{sup 0} {yields} J/{psi} {Lambda}{sup 0} is reported using data corresponding to an integrated luminosity of 4.3 fb{sup -1}, collected by the CDF II detector at the Fermilab Tevatron. The measured values are {tau}(B{sup +}) = 1.639 {+-} 0.009(stat) {+-} 0.009(syst) ps, {tau}(B{sup 0}) = 1.507 {+-} 0.010(stat) {+-} 0.008(syst) ps and {tau}({Lambda}{sub b}{sup 0}) = 1.537 {+-} 0.045(stat) {+-} 0.014(syst) ps. The lifetime ratios are {tau}(B{sup +})/{tau}(B{sup 0}) - 1.088 {+-} 0.009(stat) {+-} 0.004(syst) and {tau}({Lambda}{sub b}{sup 0})/{tau}(B{sup 0}) = 1.020 {+-} 0.030(stat) {+-} 0.008(syst). These are the most precise measurements of these quantities from a single experiment. Observation is also reported for a structure near the J/{psi}{phi} threshold, in B{sup +} to J/{psi}{phi}K{sup +} decays with an integrated luminosity of 6.0 fb{sup -1} and a statistical significance of 5 standard deviations. There are 19 {+-} 6 events observed for this structure at a mass of 4143.4{sub -3.0}{sup +2.9} {+-} 0.6 MeV/c{sup 2} and a width of 15.3{sub -6.1}{sup +10.4} {+-} 2.5 MeV/c{sup 2}.
Date: May 25, 2011
Creator: Fernandez, Juan Pablo
Object Type: Article
System: The UNT Digital Library
Study of Windows Effects for Shock Wave Temperature Measurements (open access)

Study of Windows Effects for Shock Wave Temperature Measurements

Temperature measurements of shocked plutonium are needed for improved understanding of its equation of state (EOS) and will enable better understanding and reliability of the U.S. nuclear weapon stockpile.
Date: May 25, 2011
Creator: W. D. Turley, G. Stevens, L. Veeser, D. Holtkamp, A. Seifter
Object Type: Article
System: The UNT Digital Library
DE-FG02-04ER25606 Identity Federation and Policy Management Guide: Final Report (open access)

DE-FG02-04ER25606 Identity Federation and Policy Management Guide: Final Report

The goal of this 3-year project was to facilitate a more productive dynamic matching between resource providers and resource consumers in Grid environments by explicitly specifying policies. There were broadly two problems being addressed by this project. First, there was a lack of an Open Grid Services Architecture (OGSA)-compliant mechanism for expressing, storing and retrieving user policies and Virtual Organization (VO) policies. Second, there was a lack of tools to resolve and enforce policies in the Open Services Grid Architecture. To address these problems, our overall approach in this project was to make all policies explicit (e.g., virtual organization policies, resource provider policies, resource consumer policies), thereby facilitating policy matching and policy negotiation. Policies defined on a per-user basis were created, held, and updated in MyPolMan, thereby providing a Grid user to centralize (where appropriate) and manage his/her policies. Organizationally, the corresponding service was VOPolMan, in which the policies of the Virtual Organization are expressed, managed, and dynamically consulted. Overall, we successfully defined, prototyped, and evaluated policy-based resource management and access control for OGSA-based Grids. This DOE project partially supported 17 peer-reviewed publications on a number of different topics: General security for Grids, credential management, Web services/OGSA/OGSI, policy-based grid authorization …
Date: May 25, 2011
Creator: Humphrey, Marty, A
Object Type: Report
System: The UNT Digital Library
The Timing of Aqueous Alteration in Unequilibrated Ordinary Chondrites (open access)

The Timing of Aqueous Alteration in Unequilibrated Ordinary Chondrites

None
Date: May 25, 2011
Creator: Jacobsen, B; Matzel, J; Krot, A N; Hutcheon, I D; Telus, M & Nagashima, K
Object Type: Article
System: The UNT Digital Library
AT4-CS Final Update (open access)

AT4-CS Final Update

None
Date: May 25, 2011
Creator: Moss, W. C.; Anderson, A. T. & Vignes, R. M.
Object Type: Report
System: The UNT Digital Library