Ambient-Temperature Passive Magnetic Bearings for Flywheel Energy Storage Systems (open access)

Ambient-Temperature Passive Magnetic Bearings for Flywheel Energy Storage Systems

Based on prior work at the Lawrence Livermore National Laboratory ambient-temperature passive magnetic bearings are being adapted for use in high-power flywheel energy storage systems developed at the Trinity Flywheel Power company. En route to this goal specialized test stands have been built and computer codes have been written to aid in the development of the component parts of these bearing systems. The Livermore passive magnetic bearing system involves three types of elements, as follows: (1) Axially symmetric levitation elements, energized by permanent magnets., (2) electrodynamic ''stabilizers'' employing axially symmetric arrays of permanent magnet bars (''Halbach arrays'') on the rotating system, interacting with specially wound electrically shorted stator circuits, and, (3) eddy-current-type vibration dampers, employing axially symmetric rotating pole assemblies interacting with stationary metallic discs. The theory of the Livermore passive magnetic bearing concept describes specific quantitative stability criteria. The satisfaction of these criteria will insure that, when rotating above a low critical speed, a bearing system made up of the three elements described above will be dynamically stable. That is, it will not only be stable for small displacements from equilibrium (''Earnshaw-stable''), but will also be stable against whirl-type instabilities of the types that can arise from displacement-dependent drag …
Date: May 26, 2000
Creator: Bender, D. & Post, R.
Object Type: Article
System: The UNT Digital Library
Low Cost Geothermal Separators BLISS Boundary Layer Inline Separator Scrubber (open access)

Low Cost Geothermal Separators BLISS Boundary Layer Inline Separator Scrubber

A new compact, low cost, and high performance separator is being developed to help reduce the installed and O and M cost of geothermal power generation. This device has been given the acronym ''BLISS'' that stands for ''Boundary Layer Inline Separator Scrubber''. The device is the first of a series of separators, and in the case of injectates, scrubbers to address the cost-reduction needs of the industry. The BLISS is a multi-positional centrifugal separator primarily designed to be simply installed between pipe supports, in a horizontal position. This lower profile reduces the height safety concern for workers, and significantly reduces the total installation cost. The vessel can demand as little as one-quarter (25%) the amount of steel traditionally required to fabricate many large vertical separators. The compact nature and high separating efficiency of this device are directly attributable to a high centrifugal force coupled with boundary layer control. The pseudo isokinetic flow design imparts a self-cleaning and scale resistant feature. This polishing separator is designed to remove moderate amounts of liquid and entrained solids.
Date: May 26, 2000
Creator: Jung, Douglas & Wai, King
Object Type: Report
System: The UNT Digital Library
National Ignition Facility monthly status report--April 2000 (open access)

National Ignition Facility monthly status report--April 2000

The Project provides for the design, procurement, construction, assembly, installation, and acceptance testing of the National Ignition Facility (NIF), an experimental inertial confinement fusion facility intended to achieve controlled thermonuclear fusion in the laboratory by imploding a small capsule containing a mixture of the hydrogen isotopes, deuterium and tritium. The NIF will be constructed at the Lawrence Livermore National Laboratory (LLNL), Livermore, California as determined by the Record of Decision made on December 19, 1996, as a part of the Stockpile Stewardship and Management Programmatic Environmental Impact Statement (SSM PEIS). Safety: On Saturday April 29, 2000, while preparing the Ringer crane for operation at the NIF site, a mechanical malfunction was observed by the operator. He stopped work and consulted with line management. They agreed with the operator's assessment, and with the Livermore Emergency Duty Officer, implemented a precautionary evacuation of the area around the crane. DOE was notified of the situation. The crane was then placed in a safe condition. A crane maintenance vendor is inspecting the crane and a management team headed by the Beampath Infrastructure System Associate Project Manager is reviewing the documentation, crane history, and repairs to ensure that the crane is fully safe before reuse. …
Date: May 26, 2000
Creator: Moses, Edward
Object Type: Report
System: The UNT Digital Library
Neurological Diagnostic Accelerometer (open access)

Neurological Diagnostic Accelerometer

None
Date: May 26, 2000
Creator: Balls, J.D.
Object Type: Report
System: The UNT Digital Library
Post-Remediation Biomonitoring of Pesticides and Other Contaminants in Marine Waters and Sediment Near the United Heckathorn Superfund Site, Richmond, California (open access)

Post-Remediation Biomonitoring of Pesticides and Other Contaminants in Marine Waters and Sediment Near the United Heckathorn Superfund Site, Richmond, California

Post-Remediation Biomonitoring of Pesticides and Other Contaminants in Marine Waters and Sediment Near the United Heckathorn Superfund Site, Richmond, California
Date: May 26, 2000
Creator: Antrim, Lyle D. & Kohn, Nancy P.
Object Type: Report
System: The UNT Digital Library
Post-remediation biomonitoring of pesticides and other contaminants in marine waters and sediment near the United Heckathorn Superfund Site, Richmond, California (open access)

Post-remediation biomonitoring of pesticides and other contaminants in marine waters and sediment near the United Heckathorn Superfund Site, Richmond, California

Marine sediment remediation at the United Heckathorn Superfund Site was completed in April 1997. Water and mussel tissues were sampled in February 1999 from four stations near Lauritzen Canal in Richmond, California, for Year 2 of post-remediation monitoring of marine areas near the United Heckathorn Site. Dieldrin and dichlorodiphenyl trichloroethane (DDT) were analyzed in water samples, tissue samples from resident mussels, and tissue samples from transplanted mussels deployed for 4 months. Concentrations of dieldrin and total DDT in water and total DDT in tissue were compared with Year 1 of post-remediation monitoring, and with preremediation data from the California State Mussel Watch program (tissues) and the Ecological Risk Assessment for the United Heckathorn Superfund Site (tissues and water). Mussel tissues were also analyzed for polychlorinated biphenyls (PCB), which were detected in sediment samples. Chlorinated pesticide concentrations in water samples were similar to preremediation levels and did not meet remediation goals. Mean dieidrin concentrations in water ranged from 0.62 rig/L to 12.5 ng/L and were higher than the remediation goal (0.14 ng/L) at all stations. Mean total DDT concentrations in water ranged from 14.4 ng/L to 62.3 ng/L and exceeded the remediation goal (0.59 ng/L) at all stations. The highest concentrations …
Date: May 26, 2000
Creator: Antrim, LD & Kohn, NP
Object Type: Report
System: The UNT Digital Library