RADIOISOTOPE AND RADIATION APPLICATIONS. Quarterly Progress Report (open access)

RADIOISOTOPE AND RADIATION APPLICATIONS. Quarterly Progress Report

Results of the final dynamic experiments with the ironremoval process model using Fe/sup 59/ indicated that the intrinsic-radiotracer method is rapid, accurate, and suitable for continuous readout. Results from both static and dynamic experiments on the use of Mn/sup 54/ to aid in removing manganese from process water indicated that intrinsic radiotracers can be used to help remove low-concentration critical impurities. One phase of the hazards evaluation was concerned with the ingestion of radiotracer residues which might arise from corrosion of radiotracer-containing steel products. It was concluded that no hazard exists from this source. Another part of the hazards study was concerned with the technical hazards to sensitive industries which might use steel containing radiotracer residues. This area is the most sensitive one encountered in the study. The study of the mechanism of formation of free radicals in polymeric materials was continued. Emphasis was placed on examination of the effect of structural factors on the efficiency of free-radical site formation, especially in acrylate polymers. An initial investigation of the effect of polymer tacticity was completed using polypropylene. The influence of molecular mobility on site formation in polymethylacrylate was established. Measurements of the volatile products from irradiation of the polymers was …
Date: May 2, 1961
Creator: Sunderman, D.N., ed.
System: The UNT Digital Library