Dose potential of sludge contaminated and/or TRU contaminated waste in B-25s for tornado and straight wind events (open access)

Dose potential of sludge contaminated and/or TRU contaminated waste in B-25s for tornado and straight wind events

F and H Tank Farms generate supernate and sludge contaminated Low-Level Waste. The waste is collected, characterized, and packaged for disposal. Before the waste can be disposed of, however, it must be properly characterized. Since the radionuclide distribution in typical supernate is well known, its characterization is relatively straight forward and requires minimal effort. Non-routine waste, including potentially sludge contaminated, requires much more effort to effectively characterize. The radionuclide distribution must be determined. In some cases the waste can be contaminated by various sludge transfers with unique radionuclide distributions. In these cases, the characterization can require an extensive effort. Even after an extensive characterization effort, the container must still be prepared for shipping. Therefore a significant amount of time may elapse from the time the waste is generated until the time of disposal. During the time it is possible for a tornado or high wind scenario to occur. The purpose of this report is to determine the effect of a tornado on potential sludge contaminated waste, or Transuranic (TRU) waste in B-25s [large storage containers], to evaluate the potential impact on F and H Tank Farms, and to help establish a B-25 control program for tornado events.
Date: February 17, 2000
Creator: Aponte, C.I.
System: The UNT Digital Library
User Manual for the AZ-101 Data Acquisition System (AS-101 DAS) (open access)

User Manual for the AZ-101 Data Acquisition System (AS-101 DAS)

User manual for the TK AZ-101 Waste Retrieval System Data Acquisition System. The purpose of this document is to describe use of the AZ-101 Data Acquisition System (AZ-101 DAS). The AZ-101 DAS is provided to fulfill the requirements for data collection and monitoring as defined in Letters of Instruction (LOI) from Numatec Hanford Corporation (NHC) to Fluor Federal Services (FFS). For a complete description of the system, including design, please refer to the AZ-101 DAS System Description document, RPP-5572.
Date: February 17, 2000
Creator: BRAYTON, D.D.
System: The UNT Digital Library
Am/Cm Canister Temperature Evaluation in Cim5 (open access)

Am/Cm Canister Temperature Evaluation in Cim5

To facilitate the evaluation of alternate canister designs, 2 canisters were outfitted with thermocouples at elevations of 1/2, 3 1/2, and 6 1/2 inches from the canister bottom. The canisters were fabricated from two inch diameter schedule 10 and two inch diameter schedule 40 stainless steel pipe. Each canister was filled with approximately 2 kilograms of 49 wt percent lanthanide (Ln) loaded 25SrABS glass during 5 inch Cylindrical Induction Melter (CIM5) runs for TTR Tasks 3.03 and 4.03. Melter temperature, total mass of glass poured, and the glass pour rates were almost identical in both runs. The schedule 40 canister has a slightly smaller ID compared to the schedule 10 canister and therefore filled to a level of 9.5 inches compared to 8.0 inches for the schedule 40 canister. The schedule 40 canister had an empty mass of 1906 grams compared to 919 grams for the schedule 10 canister. The schedule 10 canister was found to have a higher maximum surface temperature by about 50--100 C (depending on height) during the glass pour compared to the schedule 40 canister. The additional thermal mass of the schedule 40 canister accounts for this difference. Once filled with glass, each of the canisters …
Date: February 17, 2000
Creator: Baich, M. A.
System: The UNT Digital Library
Thermohydeologic Behavior at the Potential Yucca Mountain Nuclear Waste Repository (open access)

Thermohydeologic Behavior at the Potential Yucca Mountain Nuclear Waste Repository

Radioactive decay of high-level nuclear waste emplaced in a Yucca Mountain repository will produce an initial heat flux on the order of 30 to 50 times the heat flux in the Geysers geothermal reservoir in California (Hardin et al., 1998). Even though the rate of heat production decreases rapidly with time after emplacement, this heat flux will change the thermal and hydrologic environment, affecting both the host rock and conditions within the drifts in ways significant to key repository performance variables.
Date: February 17, 2000
Creator: Buscheck, T. A.; Rosenburg, N. D.; Gansemer, J. & Sun, Y.
System: The UNT Digital Library
Aequorin as a bioluminescent indicator for use in the determination of biomolecules in single cells. Final technical report (open access)

Aequorin as a bioluminescent indicator for use in the determination of biomolecules in single cells. Final technical report

During this funding period, the laboratories of Drs. Anderson and Daunert have performed a considerable amount of work toward addressing the issues associated with small volume analysis necessary for single cell studies. In that respect, their research has been focused on (1) developing new assays that can be miniaturized and are suitable for small volume and single cell analysis; (2) fabricating pL-vials that simulate the volume of single cells and setting up instrumentation capable of low-volume detection; (3) developing reproducible and reliable microinjection techniques; (4) developing methods of analysis for biomolecules in the pL-vials and employing these assays in the detection of biomolecules in single cells. The accomplishments attained in all these areas are described below. A total of 24 publications and 35 presentations have resulted from this work.
Date: February 17, 2000
Creator: Daunert, Sylvia
System: The UNT Digital Library
Gamma radiation stability studies of mercury fulminate (open access)

Gamma radiation stability studies of mercury fulminate

Mercury fulminate completely decomposed in a gamma source (0.86 Mrad/h) after a dose of 208 Mrad. This exposure equates to approximately 2.4 years in Tank 15H and 4 years in Tank 12H, one of the vessels of concern. Since the tanks lost the supernatant cover layer more than a decade ago, this study suggests that any mercury fulminate or closely related energetic species decomposed long ago if ever formed.
Date: February 17, 2000
Creator: Fondeur, F. F.
System: The UNT Digital Library
Measurement of DWPF glass viscosity - Final Report (open access)

Measurement of DWPF glass viscosity - Final Report

This report details the results of a scoping study funded by the Defense Waste Processing Facility (DWPF) for the measurement of melt viscosities for simulated glasses representative of Macrobatch 2 (Tank 42/51 feed).
Date: February 17, 2000
Creator: Harbour, J.R.
System: The UNT Digital Library
R Reactor seepage basins soil moisture and resistivity field investigation using cone penetrometer technology, Savannah River Site, Aiken, South Carolina (open access)

R Reactor seepage basins soil moisture and resistivity field investigation using cone penetrometer technology, Savannah River Site, Aiken, South Carolina

The focus of this report is the summer 1999 investigation of the shallow groundwater system using cone penetrometer technology characterization methods to determine if the water table is perched beneath the R Reactor Seepage Basins (RRSBs).
Date: February 17, 2000
Creator: Harris, M.K.
System: The UNT Digital Library
High performance zero-bleed CLSM/grout mixes for high-level waste tank closures strategic research and development - FY98 (open access)

High performance zero-bleed CLSM/grout mixes for high-level waste tank closures strategic research and development - FY98

The overall objective of this program, SRD-98-08, is to design and test suitable materials, which can be used to close high-level waste tanks at the Savannah River Site. Fill materials can be designed to perform several functions. They can be designed to chemically stabilize and/or physically encapsulate incidental waste so that the potential for transport of contaminants into the environment is reduced. Also they are needed to physically stabilize the void volume in the tanks to prevent/minimize future subsidence and inadvertent intrusion.
Date: February 17, 2000
Creator: Langton, C.A.
System: The UNT Digital Library
Novel 4-Way Refrigerant Reversing Valve for Heat Pumps (open access)

Novel 4-Way Refrigerant Reversing Valve for Heat Pumps

This project is nearing completion. Since the last progress report (November, 1999), all experimental tests have been completed. Preliminary analysis shows the refrigerant pressure drops through the reversing valve were reduced by an average of about 60{percent}, when compared to traditional reversing valves. Also, the prototype reversing valve reduced the overall coefficient of performance (COP) by an average of only 0.45{percent}.
Date: February 17, 2000
Creator: Nutter, Darin W.
System: The UNT Digital Library
Stability Issues in Ambient-Temperature Passive Magnetic Bearing Systems (open access)

Stability Issues in Ambient-Temperature Passive Magnetic Bearing Systems

The ambient-temperature passive magnetic bearing system developed at the Lawrence Livermore National Laboratory achieves rotor-dynamic stability by employing special combinations of levitating and stabilizing elements. These elements, energized by permanent magnet material, create the magnetic and electrodynamic forces that are required for the stable levitation of rotating systems, such as energy-storage flywheels. Stability criteria, derived from theory, describe the bearing element parameters, i.e., stiffnesses and damping coefficients, that are required both to assure stable levitation (''Earnshaw-stability''), and stability against whirl-type rotor-dynamic instabilities. The work described in this report concerns experimental measurements and computer simulations that address some critical aspects of this overall stability problem. Experimentally, a test device was built to measure the damping coefficient of dampers that employ eddy currents induced in a metallic disc. Another test device was constructed for the purpose of measuring the displacement-dependent drag coefficient of annular permanent magnet bearing elements. In the theoretical developments a computer code was written for the purpose of simulating the rotor-dynamics of our passive bearing systems. This code is capable of investigating rotor-dynamic stability effects for both small-amplitude transient displacements (i.e., those within the linear regime), and for large-amplitude displacements, where non-linear effects can become dominant. Under the latter …
Date: February 17, 2000
Creator: Post, Richard F.
System: The UNT Digital Library
Criticality Safety Evaluation of Hanford Site High Level Waste Storage Tanks (open access)

Criticality Safety Evaluation of Hanford Site High Level Waste Storage Tanks

This criticality safety evaluation covers operations for waste in underground storage tanks at the high-level waste tank farms on the Hanford site. This evaluation provides the bases for criticality safety limits and controls to govern receipt, transfer, and long-term storage of tank waste. Justification is provided that a nuclear criticality accident cannot occur for tank farms operations, based on current fissile material and operating conditions.
Date: February 17, 2000
Creator: ROGERS, C.A.
System: The UNT Digital Library
In-situ gamma-PHA measurements to support unconditional release of 235-F chiller units (open access)

In-situ gamma-PHA measurements to support unconditional release of 235-F chiller units

The Analytical Development Section of Savannah River Technology Center (SRTC) was requested by the Facility Decommission Division (FDD) to conduct in-situ gamma-ray pulse height analysis measurements to support the unconditional release of 235-F chiller units. The chiller units were used to cool process water in the 235-F facility. The measurements' main goal is to confirm that there is no process-related contaminants present on the chillers. For each of the two F-area clean water chillers, the authors have acquired ten gamma-ray pulse height analysis spectra. This report will discuss the purpose of the measurements, the experimental setup, data acquisition, calculations and results, and a conclusion of the study.
Date: February 17, 2000
Creator: Salaymeh, S.R.
System: The UNT Digital Library
Beam Control for Ion Induction Accelerators (open access)

Beam Control for Ion Induction Accelerators

Coordinated bending and acceleration of an intense space-charge-dominated ion beam has been achieved for the first time. This required the development of a variable waveform, precision, bi-polar high voltage pulser and a precision, high repetition rate induction core modulator. Waveforms applied to the induction cores accelerate the beam as the bi-polar high voltage pulser delivers a voltage ramp to electrostatic dipoles which bend the beam through a 90 degree permanent magnet quadrupole lattice. Further work on emittance minimization is also reported.
Date: February 17, 2000
Creator: Sangster, T.C. & Ahle, L.
System: The UNT Digital Library
Corrective Action Decision Document/Closure Report for Corrective Action Unit 266: Area 25 Building 3124 Leachfield, Nevada Test Site, Nevada (open access)

Corrective Action Decision Document/Closure Report for Corrective Action Unit 266: Area 25 Building 3124 Leachfield, Nevada Test Site, Nevada

This Corrective Action Decision Document/Closure Report (CADD/CR) was prepared for Corrective Action Unit (CAU) 266, Area 25 Building 3124 Leachfield, in accordance with the Federal Facility Agreement and Consent Order. Located in Area 25 at the Nevada Test Site in Nevada, CAU 266 includes Corrective Action Site (CAS) 25-05-09. The Corrective Action Decision Document and Closure Report were combined into one report because sample data collected during the corrective action investigation (CAI) indicated that contaminants of concern (COCs) were either not present in the soil, or present at concentrations not requiring corrective action. This CADD/CR identifies and rationalizes the U.S. Department of Energy, Nevada Operations Office's recommendation that no corrective action was necessary for CAU 266. From February through May 1999, CAI activities were performed as set forth in the related Corrective Action Investigation Plan. Analytes detected during the three-stage CAI of CAU 266 were evaluated against preliminary action levels (PALs) to determine COCs, and the analysis of the data generated from soil collection activities indicated the PALs were not exceeded for total volatile/semivolatile organic compounds, total petroleum hydrocarbons, polychlorinated biphenyls, total Resource Conservation and Recovery Act metals, gamma-emitting radionuclides, isotopic uranium/plutonium, and strontium-90 for any of the samples. However, …
Date: February 17, 2000
Creator: United States. National Nuclear Security Administration. Nevada Operations Office.
System: The UNT Digital Library
Plan for the Startup of HA-21I Furnace Operations at the Plutonium Finishing Plant (PFP) (open access)

Plan for the Startup of HA-21I Furnace Operations at the Plutonium Finishing Plant (PFP)

Achievement of Thermal Stabilization mission elements require the installation and startup of three additional muffle furnaces for the thermal stabilization of plutonium and plutonium bearing materials at the Plutonium Finishing Plant (PFP). The release to operate these additional furnaces will require an Activity Based Startup Review. The conduct of the Activity Based Startup Review (ABSR) was approved by Fluor Daniel Hanford on October 15, 1999. This plan has been developed with the objective of identifying those activities needed to guide the controlled startup of five furnaces from authorization to unrestricted operations by adding the HA-211 furnaces in an orderly and safe manner after the approval to Startup has been given. The Startup Plan provides a phased approach that bridges the activities between the completion of the Activity Based Startup Review authorizing the use of the three additional furnaces and the unrestricted operation of the five thermal stabilization muffle furnaces. The four phases are: (1) the initiation of five furnace operations using three empty (simulated full) boat charges from HA-211 and two full charges from HC-21C; (2) three furnace operations (one full charge from HA-211 and two full charges from HC-21C); (3) four furnace operations (two full charges from HA-211 and …
Date: February 17, 2000
Creator: Willis, H. T.
System: The UNT Digital Library