D0 Collider Detector LINDE, East Chicago (LAr Contractor) Trip Report (open access)

D0 Collider Detector LINDE, East Chicago (LAr Contractor) Trip Report

East Chicago is capable of processing air at a 6-7E6 SCFH rate. They can produce as much as 1.2E6 SCFH 02 and 4.5 SCFH N2 (not coincidently) with a peak product efficiency of 85-86% (product to total Intake). The general area demand has been as high as 10E6, as low as 4.5E6, and is currently 8E6 SCFH totaI product. The plant is really four plants in one. At anyone time one or more plants can be down for maintenance and the others online and delivering to the pipe line that distributes their product to nearby steel plants, and to the liquid reservoirs (perlite insulated tanks) of 160, 160 and 200 E6 SCF. At the time of our visit two plants were down and two were on line. The following describes the characteristics of one of the four plants. The cycle requires a base compressor (Brown Boveri, 22,600 hp) that pumps to 90-100 psig, and a booster compressor (Clark, 14,000 hp) that pumps to 300 psig. Filter houses (ca. 20-ft x 20-ft) feed the suctions and the discharge is scrubbed by dual, molecular sieve, beds 0 300 psi (6-8 hour cycle time). The beds are provided with dust blow down and …
Date: February 8, 1991
Creator: Dixon, K.; Krempetz, K.; Mulholland, G.T.; Urbin, J. & /Fermilab