Centrality and pseudorapidity dependence of charged hadron production at intermediate p{sub T} in Au+Au collisions at {radical}s{sub NN} = 130 GeV (open access)

Centrality and pseudorapidity dependence of charged hadron production at intermediate p{sub T} in Au+Au collisions at {radical}s{sub NN} = 130 GeV

We present STAR measurements of charged hadron production as a function of centrality in Au + Au collisions at {radical}s{sub NN} = 130 GeV. The measurements cover a phase space region of 0.2 < p{sub T} < 6.0 GeV/c in transverse momentum and -1 < {eta} < 1 in pseudorapidity. Inclusive transverse momentum distributions of charged hadrons in the pseudorapidity region 0.5 < |{eta}| < 1 are reported and compared to our previously published results for |{eta}| < 0.5. No significant difference is seen for inclusive p{sub T} distributions of charged hadrons in these two pseudorapidity bins. We measured dN/d{eta} distributions and truncated mean p{sub T} in a region of p{sub T} > p{sub T}{sup cut}, and studied the results in the framework of participant and binary scaling. No clear evidence is observed for participant scaling of charged hadron yield in the measured p{sub T} region. The relative importance of hard scattering process is investigated through binary scaling fraction of particle production.
Date: April 15, 2004
Creator: Adams, J.; Aggarwal, M. M.; Ahammed, Z.; Amonett, J.; Anderson, B. D.; Arkhipkin, D. et al.
Object Type: Article
System: The UNT Digital Library
Centrality and pseudorapidity dependence of charged hadron production at intermediate p{sub t} in Au+Au collisions at {radical}s{sub NN} = 130 GeV (open access)

Centrality and pseudorapidity dependence of charged hadron production at intermediate p{sub t} in Au+Au collisions at {radical}s{sub NN} = 130 GeV

We present STAR measurements of charged hadron production as a function of centrality in Au + Au collisions at {radical}s{sub NN} = 130 GeV. The measurements cover a phase space region of 0.2 < p{sub T} < 6.0 GeV/c in transverse momentum and 11 < {eta} < 1 in pseudorapidity. Inclusive transverse momentum distributions of charged hadrons in the pseudorapidity region 0.5 < |{eta}| < 1 are reported and compared to our previously published results for |{eta}| < 0.5. No significant difference is seen for inclusive p{sub T} distributions of charged hadrons in these two pseudorapidity bins. We measured dN/d{eta} distributions and truncated mean p{sub T} in a region of p{sub T} > P{sub T}{sup cut}, and studied the results in the framework of participant and binary scaling. No clear evidence is observed for participant scaling of charged hadron yield in the measured pT region. The relative importance of hard scattering process is investigated through binary scaling fraction of particle production.
Date: April 15, 2004
Creator: Adams, J.; Aggarwal, M.M.; Ahammed, Z.; Amonett, J.; Anderson, B. D.; Arkhipkin, D. et al.
Object Type: Article
System: The UNT Digital Library
Heavy Meson Production at a Low-Energy Photon Collider (open access)

Heavy Meson Production at a Low-Energy Photon Collider

A low-energy {gamma}{gamma} collider has been discussed in the context of a testbed for a {gamma}{gamma} interaction region at the Next Linear Collider(NLC). We consider the production of heavy mesons at such a testbed using Compton-backscattered photons and demonstrate that their production rivals or exceeds those by BELLE, BABAR or LEP where they are produced indirectly via virtual {gamma}{gamma} luminosities.
Date: April 15, 2004
Creator: Asztalos, S
Object Type: Article
System: The UNT Digital Library
Pore Fluid Effects on Shear Modulus for Sandstones with Soft Anisotropy (open access)

Pore Fluid Effects on Shear Modulus for Sandstones with Soft Anisotropy

A general analysis of poroelasticity for vertical transverse isotropy (VTI) shows that four eigenvectors are pure shear modes with no coupling to the pore-fluidmechanics. The remaining two eigenvectors are linear combinations of pure compression and uniaxial shear, both of which are coupled to the fluid mechanics. After reducing the problem to a 2x2 system, the analysis shows in a relatively elementary fashion how a poroelastic system with isotropic solid elastic frame, but with anisotropy introduced through the poroelastic coefficients, interacts with the mechanics of the pore fluid and produces shear dependence on fluid properties in the overall mechanical system. The analysis shows, for example, that this effect is always present (though sometimes small in magnitude) in the systems studied, and can be quite large (up to a definite maximum increase of 20 per cent) in some rocks--including Spirit River sandstone and Schuler-Cotton Valley sandstone.
Date: April 15, 2004
Creator: Berger, E. L.
Object Type: Article
System: The UNT Digital Library
Elemental Composition of a Composite of Samples HTF-E-03-162 to 164 From Tank 51H to Evaluate Acceptability of the Sludge for Transfer to Tank 40H and Processing in the DWPF (open access)

Elemental Composition of a Composite of Samples HTF-E-03-162 to 164 From Tank 51H to Evaluate Acceptability of the Sludge for Transfer to Tank 40H and Processing in the DWPF

Three dip samples of suspended sludge slurry were obtained from Tank 51H and sent to the Savannah River Technology Center for analysis. The composite of these samples is intended as a confirmatory sample to evaluate the acceptability of the Tank 51H sludge slurry for transfer to Tank 40H and for eventual processing in the Defense Waste Processing Facility. This report presents results of analyses requested by the Defense Waste Processing Facility for this evaluation. These analyses included the measurement of the concentrations of twenty two elements in the sludge slurry and the determination of the weight percent calcined solids of the slurry.
Date: April 15, 2004
Creator: Bibler, N. E.
Object Type: Report
System: The UNT Digital Library
The Influence of Calcium Carbonate Grain Coatings on Contaminant Reactivity in Vadose Zone Sediments (open access)

The Influence of Calcium Carbonate Grain Coatings on Contaminant Reactivity in Vadose Zone Sediments

None
Date: April 15, 2004
Creator: Brown, Prof. Gordon E.; Chambers, Dr. Scott; Eggleston, Prof. Carrick M. & Zachara, Dr. John M.
Object Type: Report
System: The UNT Digital Library
Omega Dante Soft X-Ray Power Diagnostic Component Calibration at the National Synchrotron Light Source (open access)

Omega Dante Soft X-Ray Power Diagnostic Component Calibration at the National Synchrotron Light Source

The Dante soft x-ray spectrometer installed on the Omega laser facility at the Laboratory for Laser Energetics, University of Rochester is a twelve-channel filter-edge defined x-ray power diagnostic. It is used to measure the absolute flux from direct drive, indirect drive (hohlraums) and other plasma sources. Calibration efforts using two beam lines, U3C (50eV-1keV) and X8A (1keV-6keV) at the National Synchrotron Light Source (NSLS) have been implemented to insure the accuracy of these measurements. We have calibrated vacuum x-ray diodes, mirrors and filters.
Date: April 15, 2004
Creator: Campbell, K; Weber, F; Dewald, E; Glenzer, S; Landen, O; Turner, R et al.
Object Type: Article
System: The UNT Digital Library
Measurement of Beryllium in Biological Samples by Accelerator Mass Spectrometry: Applications for Studying Chronic Beryllium Disease (open access)

Measurement of Beryllium in Biological Samples by Accelerator Mass Spectrometry: Applications for Studying Chronic Beryllium Disease

A method using accelerator mass spectrometry (AMS) has been developed for quantifying attomoles of beryllium (Be) in biological samples. This method provides the sensitivity to trace Be in biological samples at very low doses with the purpose of identifying the molecular targets involved in chronic beryllium disease. Proof of the method was tested by administering 0.001, 0.05, 0.5 and 5.0 {micro}g {sup 9}Be and {sup 10}Be by intraperitoneal injection to male mice and removing spleen, liver, femurs, blood, lung, and kidneys after 24 h exposure. These samples were prepared for AMS analysis by tissue digestion in nitric acid, followed by further organic oxidation with hydrogen peroxide and ammonium persulfate and lastly, precipitation of Be with ammonium hydroxide, and conversion to beryllium oxide at 800 C. The {sup 10}Be/{sup 9}Be ratio of the extracted beryllium oxide was measured by AMS and Be in the original sample was calculated. Results indicate that Be levels were dose-dependent in all tissues and the highest levels were measured in the spleen and liver. The measured {sup 10}Be/{sup 9}Be ratios spanned 4 orders of magnitude, from 10{sup -10} to 10{sup -14}, with a detection limit of 3.0 x 10{sup -14}, which is equivalent to 0.8 attomoles …
Date: April 15, 2004
Creator: Chiarappa-Zucca, M. L.; Finkel, R. C.; Martinelli, R. E.; McAninch, J. E.; Nelson, D. O. & Turtletaub, K. W.
Object Type: Article
System: The UNT Digital Library
X-ray absorption studies of the local structure and f-level occupancy in CeIr(1-x)Rh(x)In(5) (open access)

X-ray absorption studies of the local structure and f-level occupancy in CeIr(1-x)Rh(x)In(5)

The CeIr{sub 1-x}Rh{sub x}In{sub 5} series exhibits a range of interesting phenomena, including heavy-fermion superconductivity, non-Fermi liquid behavior, and concomitant antiferromagnetism (AF) and superconductivity (SC). In the low-Rh concentration range (0.1 {ge} x {ge} 0.5), specific heat measurements show a broad anomaly, suggestive of gross phase separation. We have performed x-ray absorption experiments at the Ce L{sub III}, Ir L{sub III}, and Rh K-edges as a function of Rh concentration and temperature. X-ray absorption near-edge structure (XANES) measurements indicate that cerium is close to trivalent in this system, with no measurable change with temperature from 20-300 K, consistent with a heavy-fermion material. Extended x-ray absorption fine structure (EXAFS) measurements as a function of temperature from all measured edges indicate the local crystal structure of all samples is well ordered, with no gross phase separation observed, even for samples with x = 0.125 and x = 0.25. These results therefore suggest that the anomalous specific heat behavior in the 0.1 {ge} x {ge} 0.5 range have some other explanation, and some possibilities are discussed.
Date: April 15, 2004
Creator: Daniel, M.; Han, S. W.; Booth, C. H.; Cornelius, A. L.; Pagliuso, P. G.; Sarrao, J. L. et al.
Object Type: Article
System: The UNT Digital Library
Dante Soft X-ray Power Diagnostic for NIF (open access)

Dante Soft X-ray Power Diagnostic for NIF

Soft x-ray power diagnostics are essential for measuring spectrally resolved the total x-ray flux, radiation temperature, conversion efficiency and albedo that are important quantities for the energetics of indirect drive hohlraums. At the Nova or Omega Laser Facilities, these measurements are performed mainly with Dante, but also with DMX and photo-conductive detectors (PCD's). The Dante broadband spectrometer is a collection of absolute calibrated vacuum x-ray diodes, thin filters and x-ray mirrors used to measure the soft x-ray emission for photon energies above 50 eV.
Date: April 15, 2004
Creator: Dewald, E.; Campbell, K.; Turner, R.; Holder, J.; Landen, O.; Glenzer, S. et al.
Object Type: Article
System: The UNT Digital Library
Tank 41H Saltstone Regulatory Analyses (open access)

Tank 41H Saltstone Regulatory Analyses

A Saltstone waste form was prepared in the Savannah River Technical Center (SRTC) shielded cells facility from a Tank 41H sample and Z-Area premix material. After a cure of at least 28 days, samples of the Saltstone were collected and characterized. Results showed that a Class 3 Industrial Solid Waste Landfill (ISWLF) would be required for disposal of this Tank 41H Saltstone waste form because of high leachate nitrate and alpha-emitting radionuclide concentrations.
Date: April 15, 2004
Creator: FERRARA, D
Object Type: Report
System: The UNT Digital Library
Pressure Indication of 3013 Inner Containers Using Digital Radiography (open access)

Pressure Indication of 3013 Inner Containers Using Digital Radiography

Plutonium bearing materials packaged for long term storage per the Department of Energy Standard 3013 (DOE-STD-3013) are required to be examined periodically in a non-destructive manner (i.e. without compromising the storage containers) for pressure buildup. Radiography is the preferred technology for performing the examinations. The concept is to measure and record the container lid position. As a can pressurizes the lid will deflect outward and thus provide an indication of the internal pressure. A radiograph generated within 30 days of creation of each storage container serves as the baseline from which future surveillance examinations will be compared. A problem with measuring the lid position was discovered during testing of a digital radiography system. The solution was to provide a distinct feature upon the lower surface of the container lid from which the digital radiography system could easily track the lid position.
Date: April 15, 2004
Creator: HENSEL, SJ
Object Type: Article
System: The UNT Digital Library
Radioactive Material Transportation Considerations with Respect to DOE 3013 Storage Containers (open access)

Radioactive Material Transportation Considerations with Respect to DOE 3013 Storage Containers

This paper evaluates sealed hardware that meets the requirements of DOE-STD-3013, ''Criteria for Preparing and packaging Plutonium Metals and Oxides for Long-Term Storage'' with respect to radioactive material (Type B quantity) transportation requirements. The Standard provides criteria for packaging of the plutonium materials for storage periods of at least 50 years. The standard requires the hardware to maintain integrity under both normal storage conditions and under anticipated handling conditions. To accomplish this, the standard requires that the plutonium be loaded in a minimum of two nested stainless steel sealed containers that are both tested for leak-tightness per ANSI N14.5. As such the 3013 hardware is robust. While the 3013 STD may provide appropriate storage criteria, it is not intended to provide criteria for transporting the material under the requirements of the Department of Transportation (DOT). In this evaluation, it is assumed that the activity of plutonium exceeds A1 and/or A2 curies as defined in DOT 49 CFR 173.431 and therefore must be shipped as a Type B package meeting the Nuclear Regulatory Commission (NRC) requirements of 10 CFR 71. The evaluation considers Type B shipment of plutonium in the 3013 hardware within a certified package for such contents.
Date: April 15, 2004
Creator: HENSEL, SJ
Object Type: Article
System: The UNT Digital Library
Reconstruction of quasi-monochromatic images from a multiple monochromatic x-ray imaging diagnostic for inertial confinement fusion (open access)

Reconstruction of quasi-monochromatic images from a multiple monochromatic x-ray imaging diagnostic for inertial confinement fusion

We have developed a software package for image reconstruction of a multiple monochromatic x-ray imaging diagnostics (MMI) for diagnostic of inertial conferment fusion capsules. The MMI consists of a pinhole array, a multi-layer Bragg mirror, and a charge injection device image detector (CID). The pinhole array projects {approx}500 sub-images onto the CID after reflection off the multi-layer Bragg mirror. The obtained raw images have continuum spectral dispersion on its vertical axis. For systematic analysis, a computer-aided reconstruction of the quasi-monochromatic image is essential.
Date: April 15, 2004
Creator: Izumi, N.; Turner, R.; Barbee, T.; Koch, J.; Welser, L. & Mansini, R.
Object Type: Article
System: The UNT Digital Library
Nonlinear Plasma Waves Excitation by Intense Ion Beams in Background Plasma (open access)

Nonlinear Plasma Waves Excitation by Intense Ion Beams in Background Plasma

Plasma neutralization of an intense ion pulse is of interest for many applications, including plasma lenses, heavy ion fusion, cosmic ray propagation, etc. An analytical electron fluid model has been developed to describe the plasma response to a propagating ion beam. The model predicts very good charge neutralization during quasi-steady-state propagation, provided the beam pulse duration {tau}{sub b} is much longer than the electron plasma period 2{pi}/{omega}{sub p}, where {omega}{sub p} = (4{pi}e{sup 2}n{sub p}/m){sup 1/2} is the electron plasma frequency and n{sub p} is the background plasma density. In the opposite limit, the beam pulse excites large-amplitude plasma waves. If the beam density is larger than the background plasma density, the plasma waves break. Theoretical predictions are compared with the results of calculations utilizing a particle-in-cell (PIC) code. The cold electron fluid results agree well with the PIC simulations for ion beam propagation through a background plasma. The reduced fluid description derived in this paper can provide an important benchmark for numerical codes and yield scaling relations for different beam and plasma parameters. The visualization of numerical simulation data shows complex collective phenomena during beam entry and exit from the plasma.
Date: April 15, 2004
Creator: Kaganovich, Igor D.; Startsev, Edward A. & Davidson, Ronald C.
Object Type: Report
System: The UNT Digital Library
COMPARATIVE EVALUATION OF AMBIENT FINE PARTICULATE MATTER (PM2.5) DATA OBTAINED FROM URBAN AND RURAL MONITORING SITES ALONG THE UPPER OHIO RIVER VALLEY (open access)

COMPARATIVE EVALUATION OF AMBIENT FINE PARTICULATE MATTER (PM2.5) DATA OBTAINED FROM URBAN AND RURAL MONITORING SITES ALONG THE UPPER OHIO RIVER VALLEY

Advanced Technology Systems, Inc. (ATS), with Desert Research Institute (DRI) and Ohio University as subcontractors, was contracted by the NETL in September 1998 to manage the Upper Ohio River Valley Project (UORVP), which included the establishment and operation of four ambient air monitoring sites located in the Upper Ohio River Valley (UORV). Two urban and two rural monitoring sites were included in the UORVP. The four sites selected for the UOVRP were collocated at existing local and/or state air quality monitoring stations. The goal of the UORVP was to characterize the nature and composition of PM{sub 2.5} and its precursor gases. In the process, the objectives of the UORVP were to examine the ambient air concentrations of PM{sub 2.5} as compared with the promulgated PM{sub 2.5} standards, the geographical, seasonal and temporal variations of ambient air concentrations of PM{sub 2.5}, the primary chemical constituents of PM{sub 2.5}, and the correlations between ambient air concentrations of PM{sub 2.5} and its precursor gases, other gaseous pollutants and meteorological parameters. A variety of meteorological and pollutant measurement devices, including several different PM{sub 2.5} samplers that provided either real-time or integrated concentration data, were deployed at the monitoring sites. The frequency of integrated sampling …
Date: April 15, 2004
Creator: Khosah, Robinson P.; Shimshock, John P. & Penland, Jerry L.
Object Type: Report
System: The UNT Digital Library
ENHANCED PRACTICAL PHOTOSYNTHETIC CO{sub 2} MITIGATION (open access)

ENHANCED PRACTICAL PHOTOSYNTHETIC CO{sub 2} MITIGATION

This quarterly report documents significant achievements in the Enhanced Practical Photosynthetic CO{sub 2} Mitigation project during the period from 1/2/2004 through 4/1/2004. Specific results and accomplishments for the first quarter of 2004 include: (1) CRF-2 test system: After the recent successful test results were achieved, the system was taken off-line for re-sealing and other operational improvements to prepare for the next level of testing, which will include direct measurement of carbon uptake in addition to organism mass measurements. (2) 15 biomass slurry samples are currently being analyzed with carbon dating techniques at Galbraith Labs, and statistical analysis of the results will determine if pre and post test carbon analysis is an acceptable means for carbon uptake estimation. (3) Pilot Scale: Quantitative organism growth testing is underway in the pilot scale bioreactor. Problems with uniformity of organism loading delayed the start of quantitative testing, and it remains as a continuing issue that has not been completely resolved. (4) The sustainability test was begun with approximately 30 gallons of algae and 2 Omnisil membranes. The initial mass determination procedure was completed, and the biomass growth over the course of the experiment has been preliminarily quantified.
Date: April 15, 2004
Creator: Kremer, Gregory; Bayless, David J.; Vis, Morgan; Prudich, Michael; Cooksey, Keith & Muhs, Jeff
Object Type: Report
System: The UNT Digital Library
Static and Time-Resolved 10-1000 ke V X-Ray Imaging Detector Options for NIF (open access)

Static and Time-Resolved 10-1000 ke V X-Ray Imaging Detector Options for NIF

High energy (> 10 keV) x-ray self-emission imaging and radiography will be essential components of many NIF High Energy Density Physics experiments. In preparation for such experiments, we have evaluated the pros and cons of various static (x-ray film, bare CCD, and scintillator + CCD) and time-resolved (streaked and gated) 10-1000 keV detectors.
Date: April 15, 2004
Creator: Landen, O; Bell, P; McDonald, J; Park, H; Weber, F; Moody, J et al.
Object Type: Article
System: The UNT Digital Library
Edward Teller's Scientific Life (open access)

Edward Teller's Scientific Life

Edward Teller was one of the great physicists of the twentieth century. His career began just after the key ideas of the quantum revolution of the 1920's were completed, opening vast areas of physics and chemistry to detailed understanding. Thus, his early work in theoretical physics focused on applying the new quantum theory to the understanding of diverse phenomena. These topics included chemical physics, diamagnetism, and nuclear physics. Later, he made key contributions to statistical mechanics, surface physics, solid state, and plasma physics. In many cases, the ideas in these papers are still rich with important ramifications.
Date: April 15, 2004
Creator: Libby, S B & Weiss, M S
Object Type: Article
System: The UNT Digital Library
Historical and Retrospective Survey of Monitored Natural Attenuation: A Line of Inquiry Supporting Monitored Natural Attenuation and Enhanced Passive Remediation of Chlorinated Solvents (open access)

Historical and Retrospective Survey of Monitored Natural Attenuation: A Line of Inquiry Supporting Monitored Natural Attenuation and Enhanced Passive Remediation of Chlorinated Solvents

As requested by the Savannah River Technology Center, Groundwater Services, Inc. (GSI), has conducted a historical analysis of Monitored Natural Attenuation (MNA) application at chlorinated solvent sites. The objective of the analysis was to document trends, characteristics, successes, and barriers in the use of MNA as a remedy at chlorinated solvent sites. The analysis consisted of the following: (1) a review of recent literature regarding application of natural attenuation at chlorinated solvent sites, (2) a review of regulatory and industry guidance directing evaluation and implementation of MNA as a remedy at chlorinated solvent sites, and (3) a historical survey distributed to MNA experts, which requested data relating to the evaluation and implementation of MNA at chlorinated solvent sites.
Date: April 15, 2004
Creator: Looney, B. B.
Object Type: Report
System: The UNT Digital Library
Implementation of a Near Back-Scattering Imaging System on The National Ignition Facility (open access)

Implementation of a Near Back-Scattering Imaging System on The National Ignition Facility

A near back-scattering imaging diagnostic system is being implemented on the first quad of beams on the National Ignition Facility. This diagnostic images diffusing scatter plates, placed around the final focus lenses on the NIF target chamber, to quantitatively measure the fraction of light back-scattered outside of the incident cone of the focusing optics. The imaging system consists of a wide-angle lens coupled to a gated CCD camera, providing 3mm resolution over a 2m field of view. To account for changes of the system throughput due to exposure to target debris the system will be routinely calibrated in situ at 532nm and 355nm using a dedicated pulsed laser source. The diagnostic will be described and recent results will be presented. Work performed under the auspices of the U.S. Department of Energy by UC/Lawrence Livermore National Laboratory under Contract No. W-7405-ENG-48.
Date: April 15, 2004
Creator: Mackinnon, A. J.; McCarville, T.; Niemann, C.; Piston, K.; Jones, G.; Reinbachs, I. et al.
Object Type: Article
System: The UNT Digital Library
Implementation of a high energy 4w probe beam on the Omega Laser (open access)

Implementation of a high energy 4w probe beam on the Omega Laser

An ultraviolet high-energy Thomson scattering probe beam has been implemented on the Omega laser facility at the University of Rochester. The new probe operates at a wavelength of 264nm, with a maximum energy of 260J in a pulselength of 1ns. The probe is focused with an F/6.7 lens to a minimum focal spot of 40{micro}m within a pointing tolerance of <50{micro}m. Data obtained from this probe beam has provided new diagnostic information on plasmas relevant for inertial confinement fusion and atomic physics studies.
Date: April 15, 2004
Creator: Mackinnon, A. J.; Shiromizu, S.; Antonini, G.; Haney, K.; Froula, D. H.; Moody, J. et al.
Object Type: Article
System: The UNT Digital Library
Proton Radiography as an electromagnetic field and density perturbation diagnostic (open access)

Proton Radiography as an electromagnetic field and density perturbation diagnostic

Laser driven proton beams have been used to diagnose transient fields and density perturbations in laser produced plasmas. Grid deflectometry techniques have been applied to proton radiography to obtain precise measurements of proton beam angles caused by electromagnetic fields in laser produced plasmas. Application of proton radiography to laser driven implosions has demonstrated that density conditions in compressed media can be diagnosed with MeV protons. This data has shown that proton radiography can provide unique insight into transient electromagnetic fields in super critical density plasmas and provide a density perturbation diagnostics in compressed matter . PACS numbers: 52.50.Jm, 52.40.Nk, 52.40.Mj, 52.70.Kz
Date: April 15, 2004
Creator: Mackinnon, A.; Patel, P.; Town, R.; Edwards, M.; Phillips, T.; Lerner, S. et al.
Object Type: Article
System: The UNT Digital Library
Convex Crystal X-ray Spectrometer for Laser Plasma Experiments (open access)

Convex Crystal X-ray Spectrometer for Laser Plasma Experiments

Measuring time and space-resolved spectra is important for understanding Hohlraum and Halfraum plasmas. Experiments at the OMEGA laser have used the Nova TSPEC which was not optimized for the OMEGA diagnostic space envelope or for the needed spectroscopic coverage and resolution. An improved multipurpose spectrometer snout, the MSPEC, has been constructed and fielded on OMEGA. The MSPEC provides the maximal internal volume for mounting crystals without any beam interferences at either 2x or 3x magnification. The RAP crystal is in a convex mounting geometry bent to a 20 cm radius of curvature. The spectral resolution, E/dE, is about 200 at 2.5 keV. The spectral coverage is 2 to 4.5 keV. The MSPEC can record four separate spectra on the framing camera at time intervals of up to several ns. The spectrometer design and initial field-test performance will be presented and compared to that of the TSPEC. Work supported by U. S. DoE/UC LLNL contract W-7405-ENG-48
Date: April 15, 2004
Creator: May, M.; Heeter, R. & Emig, J.
Object Type: Article
System: The UNT Digital Library