Solar heating and cooling of buildings, Phase 1 (non-residential). Recommendation for solar heating and cooling demonstrations as an integrated package (open access)

Solar heating and cooling of buildings, Phase 1 (non-residential). Recommendation for solar heating and cooling demonstrations as an integrated package

Recommendations to ERDA of four solar heating and cooling demonstration projects are presented. Recommendations include (1) the Westchester Work Center Building owned by Bell Telephone Company of Pennsylvania, (2) the Scottsdale County Courts Building in Scottsdale, Arizona, (3) Howard Johnson's Inc. Hotel in North Miami, Florida, and (4) a combination warehouse, manufacturing facility offered by Mr. John I. Ladd of Ladd Brothers, Pueblo, Colorado. A conceptual diagram and a fact sheet is included for each proposed demonstration site. The combined estimated cost for the four projects is $334,586. (WHK)
Date: February 12, 1976
Creator: unknown
System: The UNT Digital Library
Power matching for pellet fusion (open access)

Power matching for pellet fusion

The number of beams required for optimum power transfer from a given power source to the surface of a pellet is derived. The result is valid for linear optical systems, hence, for pellet fusion by laser or high energy ion beams. The optimum number of beams turns out to be inconceivably large for any practical system. Practical pellet fusion by lasers or high energy heavy ion beams must thus compromise physical principles in favor of reduced cost and optical complexity.
Date: February 12, 1976
Creator: Martin, R. L. & Arnold, R. C.
System: The UNT Digital Library