Fighting Fire with Fire: Modeling the Datacenter-Scale Effects of Targeted Superlattice Thermal Management (open access)

Fighting Fire with Fire: Modeling the Datacenter-Scale Effects of Targeted Superlattice Thermal Management

Local thermal hot-spots in microprocessors lead to worst case provisioning of global cooling resources, especially in large-scale systems. However, efficiency of cooling solutions degrade non-linearly with supply temperature, resulting in high power consumption and cost in cooling - 50 {approx} 100% of IT power. Recent advances in active cooling techniques have shown on-chip thermoelectric coolers (TECs) to be very efficient at selectively eliminating small hot-spots, where applying current to a superlattice film deposited between silicon and the heat spreader results in a Peltier effect that spreads the heat and lowers the temperature of the hot-spot significantly to improve chip reliability. In this paper, we propose that hot-spot mitigation using thermoelectric coolers can be used as a power management mechanism to allow global coolers to be provisioned for a better worst case temperature leading to substantial savings in cooling power. In order to quantify the potential power savings from using TECs in data center servers, we present a detailed power model that integrates on-chip dynamic and leakage power sources, heat diffusion through the entire chip, TEC and global cooler efficiencies, and all their mutual interactions. Our multiscale analysis shows that, for a typical data center, TECs allow global coolers to operate …
Date: November 11, 2010
Creator: Biswas, S; Tiwari, M; Theogarajan, L; Sherwood, T P & Chong, F T
Object Type: Article
System: The UNT Digital Library
Probing the eV-Mass Range for Solar Axions with CAST (open access)

Probing the eV-Mass Range for Solar Axions with CAST

The CERN Axion Solar Telescope (CAST) is searching for solar axions which could be produced in the core of the Sun via the so-called Primakoff effect. Not only would these hypothetical particles solve the strong CP problem, but they are also one of the favored candidates for dark matter. In order to look for axions originating from the Sun, CAST uses a decommissioned LHC prototype magnet. In its 10 m long magnetic field region of 9 Tesla, axions could be reconverted into X-ray photons. Different X-ray detectors are installed on both ends of the magnet, which is mounted on a structure built to follow the Sun during sunrise and sunset for a total of about 3 hours per day. The analysis of the data acquired during the first phase of the experiment with vacuum in the magnetic field region yielded the most restrictive experimental upper limit on the axion-to-photon coupling constant for axion masses up to about 0.02 eV. In order to extend the sensitivity of the experiment to a wider mass range, the CAST experiment continues its search for axions with helium in the magnet bores. In this way it is possible to restore coherence of conversion for larger …
Date: November 11, 2010
Creator: Vogel, J K; Pivovaroff, M J; Soufli, R; van Bibber, K & CAST, C
Object Type: Article
System: The UNT Digital Library
Driving Oxygen Coordinated Ligand Exchange at Nanocrystal Surfaces using Trialkylsilylated Chalcogenides (open access)

Driving Oxygen Coordinated Ligand Exchange at Nanocrystal Surfaces using Trialkylsilylated Chalcogenides

A general, efficient method is demonstrated for exchanging native oxyanionic ligands on inorganic nanocrystals with functional trimethylsilylated (TMS) chalcogenido ligands. In addition, newly synthesized TMS mixed chalcogenides leverage preferential reactivity of TMS-S bonds over TMS-O bonds, enabling efficient transfer of luminescent nanocrystals into aqueous media with retention of their optical properties.
Date: November 11, 2010
Creator: Caldwell, Marissa A.; Albers, Aaron E.; Levy, Seth C.; Pick, Teresa E.; Cohen, Bruce E.; Helms, Brett A. et al.
Object Type: Article
System: The UNT Digital Library
OSI Passive Seismic Experiment at the Former Nevada Test Site (open access)

OSI Passive Seismic Experiment at the Former Nevada Test Site

On-site inspection (OSI) is one of the four verification provisions of the Comprehensive Nuclear Test Ban Treaty (CTBT). Under the provisions of the CTBT, once the Treaty has entered into force, any signatory party can request an on-site inspection, which can then be carried out after approval (by majority voting) of the Executive Council. Once an OSI is approved, a team of 40 inspectors will be assembled to carry out an inspection to ''clarify whether a nuclear weapon test explosion or any other nuclear explosion has been carried out in violation of Article I''. One challenging aspect of carrying out an on-site inspection (OSI) in the case of a purported underground nuclear explosion is to detect and locate the underground effects of an explosion, which may include an explosion cavity, a zone of damaged rock, and/or a rubble zone associated with an underground collapsed cavity. The CTBT (Protocol, Section II part D, paragraph 69) prescribes several types of geophysical investigations that can be carried out for this purpose. One of the methods allowed by the CTBT for geophysical investigation is referred to in the Treaty Protocol as ''resonance seismometry''. This method, which was proposed and strongly promoted by Russia during …
Date: November 11, 2010
Creator: Sweeney, J. J. & Harben, P.
Object Type: Report
System: The UNT Digital Library
INTERPRETATION OF AIRBORNE ELECTROMAGNETIC AND MAGNETIC DATA IN THE 600 AREA (open access)

INTERPRETATION OF AIRBORNE ELECTROMAGNETIC AND MAGNETIC DATA IN THE 600 AREA

As part of the 200-PO-1 Phase I geophysical surveys, Fugro Airborne Surveys was contracted to collect airborne electromagnetic (EM) and magnetic surveys of the Hanford Site 600 Area. Two helicopter survey systems were used with the HeliGEOTEM{reg_sign} time domain portion flown between June 19th and June 20th, 2008, and the RESOLVE{reg_sign} frequency domain portion was flown from June 29th to July 1st, 2008. Magnetic data were acquired contemporaneously with the electromagnetic surveys using a total-field cesium vapor magnetometer. Approximately 925 line kilometers (km) were flown using the HeliGEOTEM{reg_sign} II system and 412 line kilometers were flown using the RESOLVE{reg_sign} system. The HeliGEOTEM system has an effective penetration of roughly 250 meters into the ground and the RESOLVE system has an effective penetration of roughly 60 meters. Acquisition parameters and preliminary results are provided in SGW-39674, Airborne Electromagnetic Survey Report, 200-PO-1 Groundwater Operable Unit, 600 Area, Hanford Site. Airborne data are interpreted in this report in an attempt to identify areas of likely preferential groundwater flow within the aquifer system based on the presence of paleochannels or fault zones. The premise for the interpretation is that coarser-grained intervals have filled in scour channels created by episodic catastrophic flood events during the …
Date: November 11, 2010
Creator: GD, CUMMINS
Object Type: Report
System: The UNT Digital Library
RESULTS OF THE EXAMINATION OF ELECTROCHEMICAL NOISE PROBE SPECIMENS REMOVED FROM TANK 241-AN-107 JUNE 2010 (open access)

RESULTS OF THE EXAMINATION OF ELECTROCHEMICAL NOISE PROBE SPECIMENS REMOVED FROM TANK 241-AN-107 JUNE 2010

An Integrated Multi-function Corrosion Probe (IMCP) was installed in Tank 241-AN-107 on September 20, 2006. A portion of the probe was retrieved on June 8, 2010 and the sections holding the detectors were delivered to the 222-S Laboratory for analysis. The examination and disassembly of the probe sections encountered a number of challenges. However, disassembly and relevant analyses were successfully completed. The following summarizes our observations. Brittle failure of the fiberglass probe in the middle of detector 2 resulted in the recovery of only three vapor space C-rings and six supernatant bullet specimens. The design of the bullets and how they were attached to the probe made the recovery of the components more difficult. The use of glue/epoxy on the bullets and the attachment of the flat bottom of the bullets to the curved surface of the fiberglass probe body meant that weight loss on cleaning and surface area of the specimens could not be determined with acceptable accuracy. Macrophotography of all specimens reveals that corrosion was slight in the vapor space and extremely slight in the supernatant. The one pre-cracked C-ring recovered from the vapor space still had the stress bulge visible on the polished surface, indicating that crack …
Date: November 11, 2010
Creator: GA, COOKE; RB, WYRWAS & JB, DUNCAN
Object Type: Report
System: The UNT Digital Library
THE HYDROTHERMAL REACTIONS OF MONOSODIUM TITANATE, CRYSTALLINE SILICOTITANATE AND SLUDGE IN THE MODULAR SALT PROCESS: A LITERATURE SURVEY (open access)

THE HYDROTHERMAL REACTIONS OF MONOSODIUM TITANATE, CRYSTALLINE SILICOTITANATE AND SLUDGE IN THE MODULAR SALT PROCESS: A LITERATURE SURVEY

The use of crystalline silicotitanate (CST) is proposed for an at-tank process to treat High Level Waste at the Savannah River Site. The proposed configuration includes deployment of ion exchange columns suspended in the risers of existing tanks to process salt waste without building a new facility. The CST is available in an engineered form, designated as IE-911-CW, from UOP. Prior data indicates CST has a proclivity to agglomerate from deposits of silica rich compounds present in the alkaline waste solutions. This report documents the prior literature and provides guidance for the design and operations that include CST to mitigate that risk. The proposed operation will also add monosodium titanate (MST) to the supernate of the tank prior to the ion exchange operation to remove strontium and select alpha-emitting actinides. The cesium loaded CST is ground and then passed forward to the sludge washing tank as feed to the Defense Waste Processing Facility (DWPF). Similarly, the MST will be transferred to the sludge washing tank. Sludge processing includes the potential to leach aluminum from the solids at elevated temperature (e.g., 65 C) using concentrated (3M) sodium hydroxide solutions. Prior literature indicates that both CST and MST will agglomerate and form …
Date: November 11, 2010
Creator: Fondeur, F.; Pennebaker, F. & Fink, S.
Object Type: Report
System: The UNT Digital Library
IMPACT OF REDUCING THE 100 C LIQUIDUS TEMPERATURE OFFSET ON WASTE LOADING TARGETS (open access)

IMPACT OF REDUCING THE 100 C LIQUIDUS TEMPERATURE OFFSET ON WASTE LOADING TARGETS

The objective of this report is to assess the potential impact of reducing conservatism in the implementation of the current liquidus temperature (TL) model in the Product Composition Control System (PCCS) on the ability to target higher waste loadings (WLs) for future sludge batches. No changes to the TL model or the associated uncertainties (model or measurement) are proposed, rather only changes in the magnitude of the offset used between the nominal melt pool temperature (1150 C) and the Property Acceptance Region (PAR) value (1050 C). This strategy is consistent with that outlined and initially assessed by Brown et al. (2001). In that report, the authors stated even a fairly conservative change in this safety factor could have a significant impact on waste loading. The results of this study clearly indicate that the implementation of an 1100 C TL PAR criterion (which translates into a reduction in the TL offset from 100 C to 50 C) can have significantly positive impacts on the ability to gain access to WLs exceeding 45%. This is especially true for those frit and sludge systems that are TL limited using the current 1050 C TL criterion, and are not limited by a second constraint …
Date: November 11, 2010
Creator: Peeler, D. & Edwards, T.
Object Type: Report
System: The UNT Digital Library
The Influence of Cloud Microphysics and Radiation on the Response of Water Vapor and Clouds to Climate Change (open access)

The Influence of Cloud Microphysics and Radiation on the Response of Water Vapor and Clouds to Climate Change

Uncertainties in representing the atmospheric water cycle are major obstacles to the accurate prediction of future climate. This project focused on addressing some of these uncertainties by implementing new physics for convection and radiation into the NCAR Community Atmosphere Model (CAM). To better understand and eventually better represent these processes in this major national climate model, we modified CAM3.5 to use the convection and cloud schemes developed by the Massachusetts Institute of Technology (MIT) and the RRTMG rapid radiation code for global climate models developed by Atmospheric and Environmental Research, Inc. (AER). The impact of the new physics on the CAM3.5 simulation of convection on diurnal and intra-seasonal scales, on intra-seasonal oscillations and on the distribution of water vapor has been investigated. In addition, the MIT and AER physics packages have been incorporated and tested in combination within the Weather Research and Forecasting (WRF) regional forecast model for the purpose of evaluating and improving convective and radiative processes on time scales appropriate to weather simulations. It has been found that the application of the AER radiation and MIT convection produces significant improvements in the modeled diurnal cycle of convection, especially over land, in the NCAR climate model. However, both the …
Date: November 11, 2010
Creator: Emanuel, Kerry & Iacono, Michael J.
Object Type: Report
System: The UNT Digital Library
Compression and strong rarefaction in high power impulse magnetron sputtering discharges (open access)

Compression and strong rarefaction in high power impulse magnetron sputtering discharges

Gas compression and strong rarefaction have been observed for high power impulse magnetron sputtering (HIPIMS) discharges using a copper target in argon. Time-resolved ion saturation currents of 35 probes were simultaneously recorded for HIPIMS discharges operating far above the self-sputtering runaway threshold. The argon background pressure was a parameter for the evaluation of the spatial and temporal development of the plasma density distribution. The data can be interpreted by a massive onset of the sputtering flux (sputter wind) that causes a transient densification of the gas, followed by rarefaction and the replacement of gas plasma by the metal plasma of sustained self-sputtering. The plasma density pulse follows closely the power pulse at low pressure. At high pressure, the relatively remote probes recorded a density peak only after the discharge pulse, indicative for slow, diffusive ion transport.
Date: November 11, 2010
Creator: Horwat, David & Anders, Andre
Object Type: Article
System: The UNT Digital Library
Search for a Lorentz-violating sidereal signal with atmospheric neutrinos in IceCube (open access)

Search for a Lorentz-violating sidereal signal with atmospheric neutrinos in IceCube

A search for sidereal modulation in the flux of atmospheric muon neutrinos in IceCube was performed. Such a signal could be an indication of Lorentz-violating physics. Neutrino oscillationmodels, derivable from extensions to the Standard Model, allow for neutrino oscillations that depend on the neutrino's direction of propagation. No such direction-dependent variation was found. Adiscrete Fourier transform method was used to constrain the Lorentz and CPT-violating coefficients in one of these models. Due to the unique high energy reach of IceCube, it was possible to improveconstraints on certain Lorentz-violating oscillations by three orders of magnitude with respect to limits set by other experiments.
Date: November 11, 2010
Creator: IceCube & etal, Abbasi, R,
Object Type: Article
System: The UNT Digital Library