Search for large extra dimensions in the exclusive photon + missing energy channel in p anti-p collisions (open access)

Search for large extra dimensions in the exclusive photon + missing energy channel in p anti-p collisions

A search was conducted for evidence of large extra dimensions (LED) at Fermi National Accelerator Laboratory's Tevatron using the D0 detector. The Tevatron is a p{bar p} collider at a center of mass energy of 1.96 TeV. Events with particles escaping into extra dimensions will have large missing energy. The search was carried out using data from a total luminosity of 197 {+-} 13 pb{sup -1} with an observable high transverse momentum photon and a large transverse missing energy. The 70 observed events are consistent with photons produced by standard known reactions plus other background processes produced by cosmic muons. The mass limits on the fundamental mass scale at 95% confidence level for large extra dimensions of 2, 4, 6 and 8 are 500 GeV, 581 GeV, 630 GeV, and 668 GeV respectively.
Date: April 1, 2006
Creator: Lazoflores, Jose A.
System: The UNT Digital Library
Top quarks at the Tevatron: Measurements of the top quark production and decay with the D0 experiment (open access)

Top quarks at the Tevatron: Measurements of the top quark production and decay with the D0 experiment

This thesis presents two measurements of the to pquark using 230 pb{sup -1} of data recorded with the D0 detector at the Tevatron accelerator. The first measurement determines the top pair production cross section at {radical}s = 1.96 TeV in proton-antiproton collisions. In the standard model of particle physics the top quark decays almost exclusively into a W boson and a b quark. Candidate events are selected by requiring that at least one jet in the event is tagged with the secondary vertex algorithm.
Date: April 1, 2006
Creator: Strandberg, Jonas & U., /Stockholm
System: The UNT Digital Library
Search for chargino and neutralino at Run II of the Tevatron Collider (open access)

Search for chargino and neutralino at Run II of the Tevatron Collider

In this dissertation we present a search for the associated production of charginos and neutralinos, the supersymmetric partners of the Standard Model bosons. We analyze a data sample representing 745 pb{sup -1} of integrated luminosity collected by the CDF experiment at the p{bar p} Tevatron collider. We compare the Standard Model predictions with the observed data selecting events with three leptons and missing transverse energy. Finding no excess, we combine the results of our search with similar analyses carried out at CDF and set an upper limit on the chargino mass in SUSY scenarios.
Date: August 1, 2006
Creator: Canepa, Anadi
System: The UNT Digital Library
Potential Applications of Microtesla Magnetic Resonance ImagingDetected Using a Superconducting Quantum Interference Device (open access)

Potential Applications of Microtesla Magnetic Resonance ImagingDetected Using a Superconducting Quantum Interference Device

This dissertation describes magnetic resonance imaging (MRI) of protons performed in a precession field of 132 {micro}T. In order to increase the signal-to-noise ratio (SNR), a pulsed 40-300 mT magnetic field prepolarizes the sample spins and an untuned second-order superconducting gradiometer coupled to a low transition temperature superconducting quantum interference device (SQUID) detects the subsequent 5.6-kHz spin precession. Imaging sequences including multiple echoes and partial Fourier reconstruction are developed. Calculating the SNR of prepolarized SQUID-detected MRI shows that three-dimensional Fourier imaging yields higher SNR than slice-selection imaging. An experimentally demonstrated field-cycling pulse sequence and post-processing algorithm mitigate image artifacts caused by concomitant gradients in low-field MRI. The magnetic field noise of SQUID untuned detection is compared to the noise of SQUID tuned detection, conventional Faraday detection, and the Nyquist noise generated by conducting biological samples. A second-generation microtesla MRI system employing a low-noise SQUID is constructed to increase SNR. A 2.4-m cubic, eddy-current shield with 6-mm thick aluminum walls encloses the experiment to attenuate external noise. The measured noise is 0.75 fT Hz{sup -1/2} referred to the bottom gradiometer loop. Solenoids wound from 30-strand braided wire to decrease Nyquist noise and cooled by either liquid nitrogen or water polarize the …
Date: May 18, 2006
Creator: Myers, Whittier R.
System: The UNT Digital Library
Thermo-magnetic instabilities in Nb3Sn superconducting accelerator magnets (open access)

Thermo-magnetic instabilities in Nb3Sn superconducting accelerator magnets

The advance of High Energy Physics research using circulating accelerators strongly depends on increasing the magnetic bending field which accelerator magnets provide. To achieve high fields, the most powerful present-day accelerator magnets employ NbTi superconducting technology; however, with the start up of Large Hadron Collider (LHC) in 2007, NbTi magnets will have reached the maximum field allowed by the intrinsic properties of this superconductor. A further increase of the field strength necessarily requires a change in superconductor material; the best candidate is Nb{sub 3}Sn. Several laboratories in the US and Europe are currently working on developing Nb{sub 3}Sn accelerator magnets, and although these magnets have great potential, it is suspected that their performance may be fundamentally limited by conductor thermo-magnetic instabilities: an idea first proposed by the Fermilab High Field Magnet group early in 2003. This thesis presents a study of thermo-magnetic instability in high field Nb{sub 3}Sn accelerator magnets. In this chapter the following topics are described: the role of superconducting magnets in High Energy Physics; the main characteristics of superconductors for accelerator magnets; typical measurements of current capability in superconducting strands; the properties of Nb{sub 3}Sn; a description of the manufacturing process of Nb{sub 3}Sn strands; superconducting cables; …
Date: September 1, 2006
Creator: Bordini, Bernardo & U., /Pisa
System: The UNT Digital Library
An indirect measurement of the width of the w boson at the D0 experiment (open access)

An indirect measurement of the width of the w boson at the D0 experiment

This thesis presents an indirect measurement of the width of the W boson using data collected at the D0 experiment, a multipurpose particle detector utilizing the Fermilab Tevatron. The W width was determined from the ratio of W {yields} {mu}{nu} to Z {yields} {mu}{sup +}{mu}{sup -} cross sections to be {Gamma}{sub W} = 2168 {+-} 22(stat) {+-} 62(syst){sub -16}{sup +24}(pdf) {+-} 4(other) MeV, in good agreement with the Standard Model prediction and other experimental measurements. In addition there is a description of how work made towards this measurement has been used to improve the parameterized detector simulation, a vital tool in the obtention of physics results from signals observed in the detector, and in estimating the uncertainty due to choice of PDF, which is of interest for all measurements made at hadron colliders.
Date: August 1, 2006
Creator: Telford, Paul
System: The UNT Digital Library
Measurements of Compton Scattering on the Proton at 2 - 6 GeV (open access)

Measurements of Compton Scattering on the Proton at 2 - 6 GeV

Similar to elastic electron scattering, Compton Scattering on the proton at high momentum transfers(and high p⊥) can be an effective method to study its short-distance structure. An experiment has been carried out to measure the cross sections for Real Compton Scattering (RCS) on the proton for 2.3-5.7 GeV electron beam energies and a wide distribution of large scattering angles. The 25 kinematic settings sampled a domain of s = 5−11(GeV/c)2,−t = −7(GeV/c)2 and −u = 0.5−6.5(GeV/c)2. In addition, a measurement of longitudinal and transverse polarization transfer asymmetries was made at a 3.48 GeV beam energy and a scattering angle of θcm = 120o. These measurements were performed to test the existing theoretical mechanisms for this process as well as to determine RCS form factors. At the heart of the scientific motivation is the desire to understand the manner in which a nucleon interacts with external excitations at the above listed energies, by comparing and contrasting the two existing models – Leading Twist Mechanism and Soft Overlap “Handbag” Mechanism – and identify the dominant mechanism. Furthermore, the Handbag Mechanism allows one to calculate reaction observables in the framework of Generalized Parton Distributions (GPD), which have the function of bridging the wide …
Date: May 1, 2006
Creator: Danagoulian, Areg
System: The UNT Digital Library
Exploration of deeply virtual Compton scattering on the neutron in the Hall A of Jefferson Laboratory (open access)

Exploration of deeply virtual Compton scattering on the neutron in the Hall A of Jefferson Laboratory

Generalized Parton Distributions (GPDs) are universal functions which provide a comprehensive description of hadron properties in terms of quarks and gluons. Deeply Virtual Compton Scattering (DVCS) is the simplest hard exclusive process involving GPDs. In particular, the DVCS on the neutron is mostly sensitive to E, the less constrained GPD, wich allows to access to the quark angular momentum. The first dedicated DVCS experiment on the neutron ran in the Hall A of Jefferson Lab in fall 2004. The high luminosity of the experiment and the resulting background rate recquired specific devices which are decribed in this document. The analysis methods and the experiment results, leading to preliminary constraints on the GPD E, are presented.
Date: December 8, 2006
Creator: Mazouz, Malek
System: The UNT Digital Library
Structural Investigations of Surfaces and Orientation-SpecificPhenomena in Nanocrystals and Their Assemblies (open access)

Structural Investigations of Surfaces and Orientation-SpecificPhenomena in Nanocrystals and Their Assemblies

Studies of colloidal nanocrystals and their assemblies are presented. Two of these studies concern the atomic-level structural characterization of the surfaces, interfaces, and interiors present in II-VI semiconductor nanorods. The third study investigates the crystallographic arrangement of cobalt nanocrystals in self-assembled aggregates. Crystallographically-aligned assemblies of colloidal CdSe nanorods are examined with linearly-polarized Se-EXAFS spectroscopy, which probes bonding along different directions in the nanorod. This orientation-specific probe is used, because it is expected that the presence of specific surfaces in a nanorod might cause bond relaxations specific to different crystallographic directions. Se-Se distances are found to be contracted along the long axis of the nanorod, while Cd-Se distances display no angular dependence, which is different from the bulk. Ab-initio density functional theory calculations upon CdSe nanowires indicate that relaxations on the rod surfaces cause these changes. ZnS/CdS-CdSe core-shell nanorods are studied with Se, Zn, Cd, and S X-ray absorption spectroscopy (XAS). It is hypothesized that there are two major factors influencing the core and shell structures of the nanorods: the large surface area-to-volume ratio, and epitaxial strain. The presence of the surface may induce bond rearrangements or relaxations to minimize surface energy; epitaxial strain might cause the core and shell lattices …
Date: June 17, 2006
Creator: Aruguete, Deborah Michiko
System: The UNT Digital Library
Oxidations of Organic and Inorganic Substrates by Superoxo-, hydroperoxo-, and oxo-compounds of the transition metals. (open access)

Oxidations of Organic and Inorganic Substrates by Superoxo-, hydroperoxo-, and oxo-compounds of the transition metals.

Chapters 1 and 2 dealt with the chemistry of superoxo-, hydroperoxo-, and oxo- complexes of chromium, rhodium and cobalt. Chapter 3 dealt with the mechanism of oxygen-atom transfer catalyzed by an oxo-complex of rhenium. In Chapter 1, it was shown that hydroperoxometal complexes of cobalt and rhodium react with superoxochromium and chromyl ions, generating reduced chromium species while oxidizing the hydroperoxometal ions to their corresponding superoxometal ions. It was shown that the chromyl and superoxochromium ions are the more powerful oxidants. Evidence supports hydrogen atom transfer from the hydroperoxometal ion to the oxidizing superoxochromium or chromyl ion as the reaction mechanism. There is a significant H/D kinetic isotope effect. Comparisons to the rate constants of other known hydrogen atom transfer reactions show the expected correlation with bond dissociation energies. In Chapter 2, it was found that the superoxometal complexes Cr{sub aq}OO{sup 2+} and Rh(NH{sub 3}){sub 4}(H{sub 2}O)OO{sup 2+} oxidize stable nitroxyl radicals of the TEMPO series with rate constants that correlate with the redox potentials of both the oxidant and reductant. These reactions fit the Marcus equation for electron transfer near the theoretical value. Acid catalysis is important to the reaction, especially the thermodynamically limited cases involving Rh(NH{sub 3}){sub 4}(H{sub …
Date: December 12, 2006
Creator: Vasbinder, Michael John
System: The UNT Digital Library
Mechanistic Selection and Growth of Twinned Bicrystalline Primary Si in Near Eutectic Al-Si Alloys (open access)

Mechanistic Selection and Growth of Twinned Bicrystalline Primary Si in Near Eutectic Al-Si Alloys

Morphological evolution and selection of angular primary silicon is investigated in near-eutectic Al-Si alloys. Angular silicon arrays are grown directionally in a Bridgman furnace at velocities in the regime of 10{sup -3} m/sec and with a temperature gradient of 7.5 x 10{sup 3} K/m. Under these conditions, the primary Si phase grows as an array of twinned bicrystalline dendrites, where the twinning gives rise to a characteristic 8-pointed star-shaped primary morphology. While this primary Si remains largely faceted at the growth front, a complex structure of coherent symmetric twin boundaries enables various adjustment mechanisms which operate to optimize the characteristic spacings within the primary array. In the work presented here, this primary silicon growth morphology is examined in detail. In particular, this thesis describes the investigation of: (1) morphological selection of the twinned bicrystalline primary starshape morphology; (2) primary array behavior, including the lateral propagation of the starshape grains and the associated evolution of a strong <100> texture; (3) the detailed structure of the 8-pointed star-shaped primary morphology, including the twin boundary configuration within the central core; (4) the mechanisms of lateral propagation and spacing adjustment during array evolution; and (5) the thermosolutal conditions (i.e. operating state) at the primary …
Date: December 12, 2006
Creator: Jung, Choonho
System: The UNT Digital Library
THE APPLICATION OF SINGLE PARTICLE AEROSOL MASS SPECTROMETRY FOR THE DETECTION AND IDENTIFICATION OF HIGH EXPLOSIVES AND CHEMICAL WARFARE AGENTS (open access)

THE APPLICATION OF SINGLE PARTICLE AEROSOL MASS SPECTROMETRY FOR THE DETECTION AND IDENTIFICATION OF HIGH EXPLOSIVES AND CHEMICAL WARFARE AGENTS

Single Particle Aerosol Mass Spectrometry (SPAMS) was evaluated as a real-time detection technique for single particles of high explosives. Dual-polarity time-of-flight mass spectra were obtained for samples of 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitro-1,3,5-triazinane (RDX), and pentaerythritol tetranitrate (PETN); peaks indicative of each compound were identified. Composite explosives, Comp B, Semtex 1A, and Semtex 1H were also analyzed, and peaks due to the explosive components of each sample were present in each spectrum. Mass spectral variability with laser fluence is discussed. The ability of the SPAMS system to identify explosive components in a single complex explosive particle ({approx}1 pg) without the need for consumables is demonstrated. SPAMS was also applied to the detection of Chemical Warfare Agent (CWA) simulants in the liquid and vapor phases. Liquid simulants for sarin, cyclosarin, tabun, and VX were analyzed; peaks indicative of each simulant were identified. Vapor phase CWA simulants were adsorbed onto alumina, silica, Zeolite, activated carbon, and metal powders which were directly analyzed using SPAMS. The use of metal powders as adsorbent materials was especially useful in the analysis of triethyl phosphate (TEP), a VX stimulant, which was undetectable using SPAMS in the liquid phase. The capability of SPAMS to detect high explosives and CWA …
Date: October 23, 2006
Creator: Martin, A
System: The UNT Digital Library
A measurement of the top-antitop production cross section in the dimuon final state with the D0 detector for proton-antiproton collisions as s**(1/2) = 1.96 TeV (open access)

A measurement of the top-antitop production cross section in the dimuon final state with the D0 detector for proton-antiproton collisions as s**(1/2) = 1.96 TeV

A measurement of the top pair production cross section in the dimuon final state for proton-antiproton collisions at ps = 1:96 TeV is presented. Approximately 420 pb{sup -1} of data collected with the Run II D{O} detector are used for this measurement. Two data events are observed with a total expected signal plus background yield of 3.6 events. Assuming a top mass of 175 GeV, the measured cross section is: {sigma}{sub {bar u}} = 3.13{sup +4.17}{sub -2.60}(stat){sup +0.92}{sub -0.86}(sys){+-}0.19(lumi)pb, which is consistent with a NNLO prediction of 6.77 {+-} 0.42 pb.
Date: December 1, 2006
Creator: Burke, Susan Elizabeth
System: The UNT Digital Library
On the Mechanical Properties and Microstructure of Nitinol forBiomedical Stent Applications (open access)

On the Mechanical Properties and Microstructure of Nitinol forBiomedical Stent Applications

This dissertation was motivated by the alarming number of biomedical device failures reported in the literature, coupled with the growing trend towards the use of Nitinol for endovascular stents. The research is aimed at addressing two of the primary failure modes in Nitinol endovascular stents: fatigue-crack growth and overload fracture. The small dimensions of stents, coupled with their complex geometries and variability among manufacturers, make it virtually impossible to determine generic material constants associated with specific devices. Instead, the research utilizes a hybrid of standard test techniques (fracture mechanics and x-ray micro-diffraction) and custom-designed testing apparatus for the determination of the fracture properties of specimens that are suitable representations of self-expanding Nitinol stents. Specifically, the role of texture (crystallographic alignment of atoms) and the austenite-to-martensite phase transformation on the propagation of cracks in Nitinol was evaluated under simulated body conditions and over a multitude of stresses and strains. The results determined through this research were then used to create conservative safe operating and inspection criteria to be used by the biomedical community for the determination of specific device vulnerability to failure by fracture and/or fatigue.
Date: December 15, 2006
Creator: Robertson, Scott W.
System: The UNT Digital Library
Single Molecule Screening of Disease DNA Without Amplification (open access)

Single Molecule Screening of Disease DNA Without Amplification

The potential of single molecule detection as an analysis tool in biological and medical fields is well recognized today. This fast evolving technique will provide fundamental sensitivity to pick up individual pathogen molecules, and therefore contribute to a more accurate diagnosis and a better chance for a complete cure. Many studies are being carried out to successfully apply this technique in real screening fields. In this dissertation, several attempts are shown that have been made to test and refine the application of the single molecule technique as a clinical screening method. A basic applicability was tested with a 100% target content sample, using electrophoretic mobility and multiple colors as identification tools. Both electrophoretic and spectral information of individual molecule were collected within a second, while the molecule travels along the flow in a capillary. Insertion of a transmission grating made the recording of the whole spectrum of a dye-stained molecule possible without adding complicated instrumental components. Collecting two kinds of information simultaneously and combining them allowed more thorough identification, up to 98.8% accuracy. Probing mRNA molecules with fluorescently labeled cDNA via hybridization was also carried out. The spectral differences among target, probe, and hybrid were interpreted in terms of dispersion …
Date: December 12, 2006
Creator: Lee, Ji-Young
System: The UNT Digital Library
An Analysis Framework Addressing the Scale and Legibility of Large Scientific Data Sets (open access)

An Analysis Framework Addressing the Scale and Legibility of Large Scientific Data Sets

Much of the previous work in the large data visualization area has solely focused on handling the scale of the data. This task is clearly a great challenge and necessary, but it is not sufficient. Applying standard visualization techniques to large scale data sets often creates complicated pictures where meaningful trends are lost. A second challenge, then, is to also provide algorithms that simplify what an analyst must understand, using either visual or quantitative means. This challenge can be summarized as improving the legibility or reducing the complexity of massive data sets. Fully meeting both of these challenges is the work of many, many PhD dissertations. In this dissertation, we describe some new techniques to address both the scale and legibility challenges, in hope of contributing to the larger solution. In addition to our assumption of simultaneously addressing both scale and legibility, we add an additional requirement that the solutions considered fit well within an interoperable framework for diverse algorithms, because a large suite of algorithms is often necessary to fully understand complex data sets. For scale, we present a general architecture for handling large data, as well as details of a contract-based system for integrating advanced optimizations into a …
Date: November 20, 2006
Creator: Childs, H. R.
System: The UNT Digital Library
A Search for the Production of Technicolor Particles at the D-Zero Detector (open access)

A Search for the Production of Technicolor Particles at the D-Zero Detector

A search for the Technicolor processes p{bar p} {yields} {rho}{sub T}{sup {+-}} {yields} W{sup {+-}}{pi}{sub T}{sup 0} {yields} {mu}{nu}b{bar b} and p{bar p} {yields} {rho}{sub T}{sup 0} {yields} W{sup {+-}}{pi}{sub T}{sup {+-}} {yields} {mu}{nu}b{bar c} is conducted at the D0 detector. Selection requirements are individually optimized for each of twenty mass hypotheses by means of a random grid search. No excess is seen in a 291 pb{sup -1} data set and 95% confidence level upper limits are set on the Technicolor production cross section. The mass combinations M{sub {rho}} = 195 GeV/c{sup 2}, M{sub {pi}} = 100 GeV/c{sup 2} and M{sub {rho}} = 200 GeV/c{sup 2}, M{sub {pi}} = 105 GeV/c{sup 2} are excluded for the choice of the Technicolor scale parameter M{sub V} = 500 GeV.
Date: July 1, 2006
Creator: Desai, Satish Vijay
System: The UNT Digital Library
Design of a boron neutron capture enhanced fast neutron therapy assembly (open access)

Design of a boron neutron capture enhanced fast neutron therapy assembly

The use of boron neutron capture to boost tumor dose in fast neutron therapy has been investigated at several fast neutron therapy centers worldwide. This treatment is termed boron neutron capture enhanced fast neutron therapy (BNCEFNT). It is a combination of boron neutron capture therapy (BNCT) and fast neutron therapy (FNT). It is believed that BNCEFNT may be useful in the treatment of some radioresistant brain tumors, such as glioblastoma multiform (GBM). A boron neutron capture enhanced fast neutron therapy assembly has been designed for the Fermilab Neutron Therapy Facility (NTF). This assembly uses a tungsten filter and collimator near the patient's head, with a graphite reflector surrounding the head to significantly increase the dose due to boron neutron capture reactions. The assembly was designed using Monte Carlo radiation transport code MCNP version 5 for a standard 20x20 cm{sup 2} treatment beam. The calculated boron dose enhancement at 5.7-cm depth in a water-filled head phantom in the assembly with a 5x5 cm{sup 2} collimation was 21.9% per 100-ppm {sup 10}B for a 5.0-cm tungsten filter and 29.8% for a 8.5-cm tungsten filter. The corresponding dose rate for the 5.0-cm and 8.5-cm thick filters were 0.221 and 0.127 Gy/min, respectively; about …
Date: August 1, 2006
Creator: Wang, Zhonglu & Tech, /Georgia
System: The UNT Digital Library
A Measurement of the Top Quark Mass in the Dilepton Decay Channel at CDF II (open access)

A Measurement of the Top Quark Mass in the Dilepton Decay Channel at CDF II

The top quark, the most recently discovered quark, is the most massive known fundamental fermion. Precision measurements of its mass, a free parameter in the Standard Model of particle physics, can be used to constrain the mass of the Higgs Boson. In addition, deviations in the mass as measured in different channels can provide possible evidence for new physics. We describe a measurement of the top quark mass in the decay channel with two charged leptons, known as the dilepton channel, using data collected by the CDF II detector from p{bar p} collisions with {radical}s = 1.96 TeV at the Fermilab Tevatron. The likelihood in top mass is calculated for each event by convolving the leading order matrix element describing q{bar q} {yields} t{bar t} {yields} b{ell}{nu}{sub {ell}}{bar b}{ell}'{nu}{sub {ell}'} with detector resolution functions. The presence of background events in the data sample is modeled using similar calculations involving the matrix elements for major background processes. In a data sample with integrated luminosity of 1.0 fb{sup -1}, we observe 78 candidate events and measure M{sub t} = 164.5 {+-} 3.9(stat.) {+-} 3.9(syst.) GeV/c{sup 2}, the most precise measurement of the top quark mass in this channel to date.
Date: August 1, 2006
Creator: Jayatilaka, Bodhitha A.
System: The UNT Digital Library
Search for MSSM Higgs decaying to tau pairs in ppbar collision at s**(1/2) = 1.96 TeV at CDF (open access)

Search for MSSM Higgs decaying to tau pairs in ppbar collision at s**(1/2) = 1.96 TeV at CDF

This thesis presents the search for neutral Minimal Supersymmetric extension of Standard Model (MSSM) Higgs bosons decaying to tau pairs where one of the taus decays leptonically, and the other one hadronically. CDF Run II data with L{sub int} = 310 pb{sup -1} are used. There is no evidence of MSSM Higgs existence, which results in the upper limits on {sigma}(p{bar p} {yields} {phi}) x BR({phi} {yields} {tau}{tau}) in m{sub A} range between 115 and 250 GeV. These limits exclude some area in tan {beta} vs m{sub A} parameter space.
Date: May 1, 2006
Creator: Jang, Dongwook
System: The UNT Digital Library
High Resolution Studies of the Origins of Polyatomic Ions in Inductively Coupled Plasma-Mass Spectrometry (open access)

High Resolution Studies of the Origins of Polyatomic Ions in Inductively Coupled Plasma-Mass Spectrometry

The inductively coupled plasma (ICP) is an atmospheric pressure ionization source. Traditionally, the plasma is sampled via a sampler cone. A supersonic jet develops behind the sampler, and this region is pumped down to a pressure of approximately one Torr. A skimmer cone is located inside this zone of silence to transmit ions into the mass spectrometer. The position of the sampler and skimmer cones relative to the initial radiation and normal analytical zones of the plasma is key to optimizing the useful analytical signal [1]. The ICP both atomizes and ionizes the sample. Polyatomic ions form through ion-molecule interactions either in the ICP or during ion extraction [l]. Common polyatomic ions that inhibit analysis include metal oxides (MO{sup +}), adducts with argon, the gas most commonly used to make up the plasma, and hydride species. While high resolution devices can separate many analytes from common interferences, this is done at great cost in ion transmission efficiency--a loss of 99% when using high versus low resolution on the same instrument [2]. Simple quadrupole devices, which make up the bulk of ICP-MS instruments in existence, do not present this option. Therefore, if the source of polyatomic interferences can be determined and …
Date: August 9, 2006
Creator: Ferguson, Jill Wisnewski
System: The UNT Digital Library
Designing of Metallic Photonic Structures and Applications (open access)

Designing of Metallic Photonic Structures and Applications

In this thesis our main interest has been to investigate metallic photonic crystal and its applications. We explained how to solve a periodic photonic structure with transfer matrix method and when and how to use modal expansion method. Two different coating methods were introduced, modifying a photonic structure's intrinsic optical properties and rigorous calculation results are presented. Two applications of metallic photonic structures are introduced. For thermal emitter, we showed how to design and find optimal structure. For conversion efficiency increasing filter, we calculated its efficiency and the way to design it. We presented the relation between emitting light spectrum and absorption and showed the material and structural dependency of the absorption spectrum. By choosing a proper base material and structural parameters, we can design a selective emitter at a certain region we are interested in. We have developed a theoretical model to analyze a blackbody filament enclosed by a metallic mesh which can increase the efficiency of converting a blackbody radiation to visible light. With this model we found that a square lattice metallic mesh enclosing a filament might increase the efficiency of incandescent lighting sources. Filling fraction and thickness dependency were examined and presented. Combining these two parameters …
Date: August 9, 2006
Creator: Kim, Yong-Sung
System: The UNT Digital Library
The Nature of the Distinctive Microscopic Features in R5(SixGe1-x)4 Magnetic Refrigeration Materials (open access)

The Nature of the Distinctive Microscopic Features in R5(SixGe1-x)4 Magnetic Refrigeration Materials

Magnetic refrigeration is a promising technology that offers a potential for high energy efficiency. The giant magnetocaloric effect of the R{sub 5}(Si{sub x}, Ge{sub 1-x}){sub 4} alloys (where R=rare-earth and O {le} x {le} 1), which was discovered in 1997, make them perfect candidates for magnetic refrigeration applications. In this study the microstructures of Gd{sub 5}(Si{sub x}Ge{sub 1-x}){sub 4} alloys have been characterized using electron microscopy techniques, with the focus being on distinctive linear features first examined in 1999. These linear features have been observed in R{sub 5}(Si{sub x}, Ge{sub 1-x}){sub 4} alloys prepared from different rare-earths (Gd, Tb, Dy and Er) with different crystal structures (Gd{sub 5}Si{sub 4}-type orthorhombic, monoclinic and Gd{sub 5}Ge{sub 4}-type orthorhombic). Systematic scanning electron microscope studies revealed that these linear features are actually thin-plates, which grow along specific directions in the matrix material. The crystal structure of the thin-plates has been determined as hexagonal with lattice parameters a=b=8.53 {angstrom} and c=6.40 {angstrom} using selected area diffraction (SAD). Energy dispersive spectroscopy analysis, carried out in both scanning and transmission electron microscopes, showed that the features have a composition approximating to R{sub 5}(Si{sub x},Ge{sub 1-x}){sub 3}.phase. Orientation relationship between the matrix and the thin-plates has been calculated …
Date: May 1, 2006
Creator: Ugurlu, Ozan
System: The UNT Digital Library
Magnetic Tools for Lab-on-a-chip Technologies (open access)

Magnetic Tools for Lab-on-a-chip Technologies

This study establishes a set of magnetics-based tools that have been integrated with microfluidic systems. The overall impact of the work begins to enable the rapid and efficient manipulation and detection of magnetic entities such as particles, picoliter-sized droplets, or bacterial cells. Details of design, fabrication, and theoretical and experimental assessments are presented. The manipulation strategy has been demonstrated in the format of a particle diverter, whereby micron-sized particles are actively directed into desired flow channels at a split-flow junction by means of integrated microelectromagnets. Magnetic detection has been realized by deploying Giant Magnetoresistance (GMR) sensors--microfabricated structures originally developed for use as readout elements in computer hard-drives. We successfully transferred the GMR technology to the lab-on-a-chip arena, and demonstrated the versatility of the concept in several important areas: real-time, integrated monitoring of the properties of multiphase droplet flows; rapid quantitative determination of the concentration of magnetic nanoparticles in droplets of ferrofluids; and high-speed detection of individual magnetic microparticles and magnetotactic bacteria. The study also includes novel schemes for hydrodynamic flow focusing that work in conjunction with GMR-based detection to ensure precise navigation of the sample stream through the GMR detection volume, therefore effectively establishing a novel concept of a microfabricated …
Date: August 5, 2006
Creator: Pekas, Nikola Slobodan
System: The UNT Digital Library