The Solubility of Helium in Tuballoy (open access)

The Solubility of Helium in Tuballoy

This technical report summarizes the work done in attempting to determine the solubility of helium in tuballoy. In general, the method used has been to allow the tuballoy to stand in contact with helium at one atmosphere presume at a fixed temperature for an extended period, then to pump off the excess helium to a low pressure in as short a time as possible (10-6 mm of Hg or less). The system was then closed off and the pressure increase was measured by a suitable gauge as a function of time. The metal was employed in the form of a powder in early measurements, and later as massive metal. The experimental techniques are described in the report.
Date: June 26, 1945
Creator: Seltz , H. & Young, C. W.