Proposed method for determining the thickness of glass in solar collector panels (open access)

Proposed method for determining the thickness of glass in solar collector panels

An analytical method has been developed for determining the minimum thickness for simply supported, rectangular glass plates subjected to uniform normal pressure environmental loads such as wind, earthquake, snow, and deadweight. The method consists of comparing an analytical prediction of the stress in the glass panel to a glass breakage stress determined from fracture mechanics considerations. Based on extensive analysis using the nonlinear finite element structural analysis program ARGUS, design curves for the structural analysis of simply supported rectangular plates have been developed. These curves yield the center deflection, center stress and corner stress as a function of a dimensionless parameter describing the load intensity. Results are included for plates having length-to-width ratios of 1, 1.5, 2, 3, and 4. The load range considered extends to 1000 times the load at which the behavior of the plate becomes significantly nonlinear. Over the load range analyzed, the analysis shows that the ratio of center deflection to plate thickness for a plate of length-to-width ratio of 4 is less than 70 to 1, whereas linear theory would predict a center deflection about 1200 times the plate thickness. The stress is also markedly lower than would be predicted by linear theory. These analytical …
Date: March 1, 1980
Creator: Moore, D.M.
System: The UNT Digital Library
Photovoltaic module design, qualification, and testing specification. Low-Cost Solar Array Project (open access)

Photovoltaic module design, qualification, and testing specification. Low-Cost Solar Array Project

This specification establishes minimum design, qualification and acceptance requirements for terrestrial solar cell modules suitable for incorporation in photovoltaic array applications in the 20kW to 500kW range, such as defined by Department of Energy PRDA EM-D-04-0038. Both mandatory and recommended requirement levels for selected performance criteria have been specified for modules within these arrays. As applicable, the manufacturer/contractor shall be responsible for generation and selection of appropriate design or test levels within the scope of these criteria. Specification of any additional requirements as necessary to satisfy the particular array or system application shall be the responsibility of the manufacturer/contractor. Environmental requirements imposed by this specification are considered to be the minimum level acceptable to DOE. Test procedures are detailed.
Date: March 24, 1978
Creator: unknown
System: The UNT Digital Library
Photovoltaic module design, qualification and testing specification (open access)

Photovoltaic module design, qualification and testing specification

This specification establishes minimum design, qualification and acceptance requirements for terrestrial solar cell modules suitable for incorporation in photovoltaic array applications in the 20 kW to 500 kW range, such as defined by Department of Energy PRDA EM-D-04-0038. Both mandatory and recommended requirement levels for selected performance criteria have been specified for modules within these arrays. As applicable, the manufacturer/contractor shall be responsible for generation and selection of appropriate design or test levels within the scope of these criteria. Specification of any additional requirements as necessary to satisfy the particular array or system application shall be the responsibility of the manufacturer/contractor. Environmental requirements imposed by this specification are considered to be the minimum level acceptable to DOE.
Date: March 24, 1978
Creator: unknown
System: The UNT Digital Library