APPLYING SIMPLE TECHNOLOGY ACCOMPLISHES VISUAL INSPECTION CHALLENGES (open access)

APPLYING SIMPLE TECHNOLOGY ACCOMPLISHES VISUAL INSPECTION CHALLENGES

This paper discusses the successful implementation of simple video technologies at the Savannah River Site (SRS) to perform complex visual inspection, monitoring, and surveillance tasks. Because SRS facilities are similar to those of an industrial plant, the environmental and accessibility considerations for remote viewing are the primary determining factors in the selection of technology. The constraints and challenges associated with remote viewing are discussed, and examples of applications are given.
Date: July 21, 2007
Creator: Robinson, C.
Object Type: Article
System: The UNT Digital Library
Contemporary Instrumentation and Application of Charge Exchange Neutral Particle Diagnostics in Magnetic Fusion Experiments (open access)

Contemporary Instrumentation and Application of Charge Exchange Neutral Particle Diagnostics in Magnetic Fusion Experiments

An overview of the developments post-circa 1980's of the instrumentation and application of charge exchange neutral particle diagnostics on Magnetic Fusion Energy experiments is presented.
Date: July 21, 2007
Creator: S.S. Medley, A.J.H. Donné, R. Kaita, A.I. Kislyakov, M.P. Petrov, and A.L. Roquemore
Object Type: Report
System: The UNT Digital Library
Cygnus PFL Switch Jitter (open access)

Cygnus PFL Switch Jitter

The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources: Cygnus 1 and Cygnus 2. Each source has the following X-ray output: 1-mm diameter spot size, 4 rads at 1 m, 50-ns full-widthhalf-maximum. The diode pulse has the following electrical specifications: 2.25 MV, 60 kA, 60 ns. This Radiographic Facility is located in an underground tunnel test area at the Nevada Test Site (NTS). The sources were developed to produce high-resolution images on subcritical tests performed at NTS. Subcritical tests are single-shot, high-value events. For this application, it is desirable to maintain a high level of reproducibility in source output. The major components of the Cygnus machines are Marx generator, water-filled pulse forming line (PFL), water-filled coaxial transmission line, threecell inductive voltage adder, and rod-pinch diode. A primary source of fluctuation in Cygnus shot-to-shot performance may be jitter in breakdown of the main PFL switch, which is a “self-break” switch. The PFL switch breakdown time determines the peak PFL charging voltage, which ultimately affects the source X-ray spectrum and dose. Therefore, PFL switch jitter may contribute to shot-to-shot variation in these parameters, which are crucial to radiographic quality. In this paper we will present PFL switch jitter analysis …
Date: July 21, 2007
Creator: Mitton, C.; Corrow, G. & Henderson, D.
Object Type: Article
System: The UNT Digital Library
"Super" Cocktails for Heavy Ion Testing (open access)

"Super" Cocktails for Heavy Ion Testing

The 4.5 MeV/nucleon heavy ion cocktail at the 88-Inch Cyclotron has been expanded by incorporating beams from solid material to fill in the linear energy transfer curve. This supercocktail is available by special request and is useful when only normal incidence between the beam and the device under test is possible or desirable.
Date: July 21, 2007
Creator: Johnson, Michael B; Johnson, Michael B.; McMahan, Margaret A.; Galloway, Michelle; Leitner, Daniela; Morel, James R. et al.
Object Type: Article
System: The UNT Digital Library
Treatability Test Plan for an In Situ Biostimulation Reducing Barrier (open access)

Treatability Test Plan for an In Situ Biostimulation Reducing Barrier

This treatability test plan supports a new, integrated strategy to accelerate cleanup of chromium in the Hanford 100 Areas. This plan includes performing a field-scale treatability test for bioreduction of chromate, nitrate, and dissolved oxygen. In addition to remediating a portion of the plume and demonstrating reduction of electron acceptors in the plume, the data from this test will be valuable for designing a full-scale bioremediation system to apply at this and other chromium plumes at Hanford.
Date: July 21, 2007
Creator: Truex, Michael J.; Vermeul, Vince R.; Long, Philip E.; Brockman, Fred J.; Oostrom, Mart; Hubbard, Susan et al.
Object Type: Report
System: The UNT Digital Library