D0 Silicon Upgrade: CTF Front End Crate J2/J3 BAckplane Specification (open access)

D0 Silicon Upgrade: CTF Front End Crate J2/J3 BAckplane Specification

GENERAL PHYSICAL LAYOUT: (1) The backplane is comprised of 2 identical sections, the upper half designated J1, and the lower half designated j3; (2) For each section, there are a total of 16 slots, designated 1 through 16, from left to right; (3) Odd numbered slots are left handed (Connectors to the left of the card), these slots utilize inverse DIN connectors; (4) Even numbered slots are right handed (Connectors to the right of the card), these slots utilize standard DIN connectors; (5) There are 2 60 pin daisy-chain headers associated with each section, 3M part number 3597-6003; (6) The headers associated with the J2 (upper) section are designated J2CHAINR and J2CHAINL; (7) The headers associated with the J3 (lower) section are designated J3CHAINL and J3CHAINR; and (8) Mechanical layout presented in drawing number 3823.113-MD-330045. TRIGGER SIGNALS: (1) There are 21 trigger signal which originate from a given slot and are routed to the slot immediately to the left and 21 trigger signals which originate from a given slot and are routed to the slot immediately to the right; (2) There are 21 trigger signals which originate from the slot immediately to the left of a given slot and 21 …
Date: July 3, 1995
Creator: Baert, Mark
System: The UNT Digital Library
San Antonio Monthly Reports: June 1995 [Part 1] (open access)

San Antonio Monthly Reports: June 1995 [Part 1]

Compilation of monthly reports from departments in the city of San Antonio, Texas providing statistics, project updates, and other information about services and activities.
Date: July 3, 1995
Creator: San Antonio (Tex.)
System: The Portal to Texas History
Semi-annual report of the Department of Energy, Office of Environmental Management, Quality Assessment Program (open access)

Semi-annual report of the Department of Energy, Office of Environmental Management, Quality Assessment Program

This report presents the results from the analysis of the 42st set of environmental quality assessment samples (QAP XLII) that were received on or before June 1, 1995. This Quality Assessment Program (QAP) is designed to test the quality of the environmental measurements being reported to the Department of Energy by its contractors. Since 1976, real or synthetic environmental samples that have been prepared and thoroughly analyzed at the Environmental Measurements Laboratory (EML) have been distributed at first quarterly and then semi-annually to these contractors. Their results, which are returned to EML within 90 days, are compiled with EML`s results and are reported back to the participating contractors 30 days later. A summary of the reported results is available to the participants 2 days after the reporting deadline via a modem-telephone connection to the EML computer.
Date: July 3, 1995
Creator: Sanderson, C.G.; Greenlaw, P. & Pan, V.
System: The UNT Digital Library