Optical Time-Domain Reflectometer Performance and Calibration Studies (open access)

Optical Time-Domain Reflectometer Performance and Calibration Studies

from Introduction: The measurement accuracy of the optical time-domain reflectometer (OTDR) is restricted in some applications by a limited operational dynamic range and by a lack of standardized test procedures. In an effort to better understand these restrictions, we have measured the range of linearity of some avalanche photodiodes used as backscatter detectors. Also, the effect of input launch conditions is examined and a possible standardized OTDR test procedure is proposed. Using these suggestions, we have made comparisons between attenuation values determined by cutback and backscatter methods and found that good agreement is possible. Finally, some methods are described for checking the response. linearity of OTDR systems.
Date: June 1983
Creator: Danielson, B. L.
System: The UNT Digital Library
A Near-Field Array of Yagi-Uda Antennas for Electromagnetic Susceptibility Testing (open access)

A Near-Field Array of Yagi-Uda Antennas for Electromagnetic Susceptibility Testing

Abstract: In electromagnetic susceptibility testing of electronic equipment, the ideal incident field is a plane wave. To approximate this condition, a seven-element array of Yagi-Uda antennas has been constructed and tested at a frequency of 500 MHz. The element weightings are determined by a near-field synthesis technique which optimizes the uniformity of the field throughout a rectangular test volume in the near field of the array. The amplitude and phase of the electric field have been measured throughout the test volume with a short dipole probe, and the agreement with the theory is excellent.
Date: June 1985
Creator: Hill, David A. & Koepke, Galen H.
System: The UNT Digital Library
Tables of Industrial Gas Container Contents and Density for Oxygen, Argon, Nitrogen, Helium, and Hydrogen (open access)

Tables of Industrial Gas Container Contents and Density for Oxygen, Argon, Nitrogen, Helium, and Hydrogen

Abstract: Custody transfer tables are presented for oxygen, argon, nitrogen, helium, and hydrogen. The tables are based on standard reference data previously compiled by the National Bureau of Standards. Two sets of tables are provided for each fluid. Tables in engineering units cover the range -40 to 130*F with pressures from 100 to 10,000 prig. Tables in SI units (density versus pressure and temperature) cover the range 200 to 370 K with pressures from 0.5 to 70 MPa. The tables in engineering units are designed to provide a means of determining the volume of gas at standard conditions contained in a tank given the volume of the tank and the pressure and temperature of the gas within the tank. The publication also includes four examples of use of the tables in calculating tank quantities.
Date: June 1985
Creator: Younglove, Ben A. & Olien, Neil A.
System: The UNT Digital Library
Shielded Balanced and Coaxial Transmission Lines: Parametric Measurements and Instrumentation Relevant to Signal Waveform Transmission in Digital Service (open access)

Shielded Balanced and Coaxial Transmission Lines: Parametric Measurements and Instrumentation Relevant to Signal Waveform Transmission in Digital Service

Abstract: A method is presented for determining the impulse and step responses of a shielded cable using time domain terminal measurements and a physically based mathematical model for the transmission line properties of the cable. The method requires a computer controlled time domain measurement system and was implemented using the NBS Automatic Pulse Measurement System (APMS). Data are also developed for the frequency domain complex propagation function (attenuation and its related minimum-phase shift). The method is applied to 12 shielded paired-conductor (balanced) cables and 5 coaxial cables. Time domain responses are presented for three nominal cable lengths, 60 m (200 ft), 150 m (500 ft), and 300 m (1000 ft). The time domain responses are applied to the estimation of bit error rate increases due to the insertion of the cables into a digital signaling system employing a balanced polar NRZ waveform. Also discussed is the application of the time domain responses to time domain reflectometry techniques for cable acceptance tests and field-site testing of installed cables.
Date: June 1981
Creator: Gans, William L. & Nahman, N. S.
System: The UNT Digital Library
The Characterization of Optical Fiber Waveguides: A Bibliography with Abstracts, 1970-1980 (open access)

The Characterization of Optical Fiber Waveguides: A Bibliography with Abstracts, 1970-1980

Abstract: This bibliography contains approximately 450 citations of papers concerning the characterization of optical fiber waveguides. Papers from scientific journals, trade journals and conferences are included along with book chapters. The citations of organized by parameter measured and measurement method. Where published abstracts are available they are included.
Date: June 1981
Creator: Day, G. W.
System: The UNT Digital Library
WR 10 Millimeter Wave Microcalorimeter (open access)

WR 10 Millimeter Wave Microcalorimeter

Abstract: A microcalorimeter has been built in WR 10 waveguide, 75-110 GHz, to serve as a power standard at the National Bureau of Standards (NBS). Included here is an evaluation of the errors in using the microcalorimeter for the measurement of effective efficiency of bolometer mounts. The error analysis shows a systematic uncertainty of +/- .83 percent and a random uncertainty of .37 percent.
Date: June 1981
Creator: Weidman, Manly P. & Hudson, Paul A.
System: The UNT Digital Library
Tests of Commercial Densimeters for LNG Service (open access)

Tests of Commercial Densimeters for LNG Service

Abstract: Densimeters for liquefied natural gas (LNG) from four manufacturers were tested in liquid methane and an LNG-like mixture of methane, propane, and nitrogen in the density reference system (DRS). The calibration and performance of one type tested for the first time are reported. The stability of the calibrations and performances of three densimeters of a type previously tested have been examined and are also reported here.
Date: June 1982
Creator: Siegwarth, J. D. & LaBrecque, J. F.
System: The UNT Digital Library
Transparent Metrology of Signal to Noise Ratios of Noisy Band-Limited Digital Signals (open access)

Transparent Metrology of Signal to Noise Ratios of Noisy Band-Limited Digital Signals

From abstract: I propose the use of a template method for quantitative, correct, and transparent measurement of signal power to additive noise power ratios (SNR) of digital signals and systems under full operating conditions. Outer guard chips of digital templates hold intersymbol interference fixed on inner target chips in realizations of the respective template patterns in traffic. The proposed template method needs to be developed and proven as a potentially valuable metrology capability; it can be especially important for real time online performance assessment and monitoring of digital communication systems.
Date: June 1985
Creator: Halford, Donald
System: The UNT Digital Library
Temperature-Entropy Diagram for Parahydrogen Triple-Point Region (open access)

Temperature-Entropy Diagram for Parahydrogen Triple-Point Region

Graphical presentation of he three-phase region at and near the triple point of parahydrogen.
Date: June 22, 1966
Creator: Sindt, C. F. & Mann, D. B.
System: The UNT Digital Library
Glass Limit Standards Deposited at NBS for Railway, Highway, and Airways Traffic Signal Colors: History, Permanence and Colorimetric Properties (open access)

Glass Limit Standards Deposited at NBS for Railway, Highway, and Airways Traffic Signal Colors: History, Permanence and Colorimetric Properties

Permanence and colorimetric properties of signal glass.
Date: June 1971
Creator: Haupt, Geraldine W.
System: The UNT Digital Library