KER-1 thermal cycle (open access)

KER-1 thermal cycle

Enclosed is the data that was collected during the recent thermal cycle of KER-1. This data includes the RTD readings and information taken from the thermocouple fuel element. In conjunction with obtaining data on film build-up, the test provided an excellent opportunity to study the effect of temperature on measured tube power. It has been noticed that the KER reactor tubes appear to produce more power (greater {Delta}T) at lower operating temperatures, but the reason for this power increase is not known. With the additional thermocouples to measure water temperatures at the center of the tube, it should be possible to determine if this increase is from the graphite or from the fuel elements.
Date: June 28, 1960
Creator: Poe, J. L.
Object Type: Report
System: The UNT Digital Library
Texas Attorney General Opinion: WW-865 (open access)

Texas Attorney General Opinion: WW-865

Document issued by the Office of the Attorney General of Texas in Austin, Texas, providing an interpretation of Texas law. It provides the opinion of the Texas Attorney General, Will Wilson, regarding a legal question submitted for clarification: Whether the Texas Youth Council has the authority, under existing law, to furnish a prescribed uniform for staff members under their control to wear while carrying our their duties, and related questions.
Date: June 28, 1960
Creator: Texas. Attorney-General's Office.
Object Type: Text
System: The Portal to Texas History
Texas Attorney General Opinion: WW-868 (open access)

Texas Attorney General Opinion: WW-868

Document issued by the Office of the Attorney General of Texas in Austin, Texas, providing an interpretation of Texas law. It provides the opinion of the Texas Attorney General, Will Wilson, regarding a legal question submitted for clarification: Legal Status of Texas Public Junior Colleges as regards their eligibility for financial assistance under Title III of the National Defense Education Act of 1958.
Date: June 28, 1960
Creator: Texas. Attorney-General's Office.
Object Type: Text
System: The Portal to Texas History
Accelerator Beam Pulsing System With Extremely Wide Range of Pulse Lengths and Pulse Repetition Rates (open access)

Accelerator Beam Pulsing System With Extremely Wide Range of Pulse Lengths and Pulse Repetition Rates

The following document describes the usage and results of sending pulsed beams of electrically charged particles with electrically wide range of pulse lengths and pulse repetition rates.
Date: June 28, 1960
Creator: Aaland, Kristian
Object Type: Report
System: The UNT Digital Library
Contoured I&E sleeves (open access)

Contoured I&E sleeves

The feasibility of contoured I&E cans for production use has been demonstrated using our present flat base I&E sleeve (HW-37187). Studies by Process Engineering and Quality Control have shown that only a material savings would result from the use of only the contoured I&E can. Consideration was then given to the use of contoured sleeves (H-3-16879) to improve the contact areas and the resulting heat transfer during fuel assembly.
Date: June 28, 1960
Creator: Burgess, C. A.
Object Type: Report
System: The UNT Digital Library
TEST OF HRT-CP MULTICLONE NO. 1 FOLLOWING REMOVAL FROM REACTOR CELL (open access)

TEST OF HRT-CP MULTICLONE NO. 1 FOLLOWING REMOVAL FROM REACTOR CELL

The multiple hydroclone unit, or multiclone, installed in the reactor cell prior to run 20, in an effort to increase the solids removal rate of the hydrcclone system, was removed after 4500 hr of operation (end of HRT run 21). Examination and tests of this unit after removal indicated an accumulation of about 100 g of solids in the feed chamber and partial plugging of one to three hydroclone feed ports. The plugged hydroclones would permit flow from the underflow pot to the overflow stream and continuously flush solids from the underflow pot. This flow would probably reduce the efficiency of the multiclone unit to zero in the induced underflow condition and significantly reduce the efficiency with the cell "C" hydroclone on stream. (auth)
Date: June 28, 1960
Creator: Yarbro, O O
Object Type: Report
System: The UNT Digital Library
Bubble Chamber Safety Meeting (open access)

Bubble Chamber Safety Meeting

A description is given of bubble chambers in use and those in the design stages. Safety factors in the design and operation of a bubble chamber are discussed. Data are presented on fatige and rupture tests on glass. Data are contained on the effects of liquid helium on the tensile properties of various stainless steels. (C.J.G.)
Date: June 28, 1960
Creator: Harrer, J. M.
Object Type: Report
System: The UNT Digital Library
High Current Pulsed Electron Accelerator (open access)

High Current Pulsed Electron Accelerator

The most important component required for the Astron experimental facility is a high energy, high current, pulsed electron accelerator. A thin cylindrical layer of high energy electrons trapped within an axially symmetric magnetic field is the key feature of the Astron thermonuclear device. The trapping magnetic field is constant in time. Therefore, it is not possible to inject electrons and trap the electrons in this field unless during the injection phase a part of the electron energy is absorbed by some friction process. This is accomplished by means of eddy currents generated on suitable passive circuits by the current of the injected electron bunch. This method has ben described elsewhere. However, in order to achieve an effective loss mechanism the current of the injected electron beam must be over one hundred amps. Such high current beams are difficult to handle except if the electron energy is high enough so that the electrostatic repulsive force is compensated to great extent by attractive magnetive forces. Hence the electron energy required is 5 Mev or higher. Other requirements on the electron layer yield the same result.
Date: June 28, 1960
Creator: Christofilos, Nicholas C.
Object Type: Report
System: The UNT Digital Library
EEN-333, revised getter flash procedure (open access)

EEN-333, revised getter flash procedure

EWR No. VTE-188--Tubes processed by flashing getters immediately prior to seal-off from vacuum systems are compared for total residual gas pressure to tubes processed by flashing getters after tubes were sealed off vacuum systems. Comparisons of residual pressures determined from current flows in the cold cathode ion gauge.
Date: June 28, 1960
Creator: Brown, W.C.
Object Type: Report
System: The UNT Digital Library
On the Kinetic Theory of Steady Gas Flows (open access)

On the Kinetic Theory of Steady Gas Flows

An approximate Boltzmann equation, known as the single relaxation model is studied here. This equation is linearized and the fundamental solution is considered. Following N. Grad, the solution, asymptotic in small values of the ratio of mean-free-path to distance from the origin, is sought. It can be shown that the fundamental solution itself gives the asymptotic description of the flow field past an object. This solution gives the asymptotic description when the distance from the origin is much greater than either the mean-free-path or the body size. This is true independently of the Knudsen number.
Date: June 28, 1960
Creator: Sirovich, L., 1933-
Object Type: Report
System: The UNT Digital Library
Thickness Measurement by Ultrasonic Frequency Modulation (open access)

Thickness Measurement by Ultrasonic Frequency Modulation

A prototype instrument has been designed and built which demonstrates an ultrasonic pulse echo technique of measuring metal thickness in the range .010 to .080 inches. Extension of the range of measurement on the thick side appears straightforward, however, transducer frequency response considerations may limit the extension of the method for very thin sections. The instrument is based upon the principle that sections, when driven by pulses of vibratory energy, resonate at frequencies dependent upon the thickness of the section.
Date: June 28, 1960
Creator: Lambert, T.G.
Object Type: Report
System: The UNT Digital Library