Compensation for the eddy current effect in the APS storage ring vacuum chamber (open access)

Compensation for the eddy current effect in the APS storage ring vacuum chamber

The amplitude attenuation and the phase shift of the correction magnet field inside the APS storage ring vacuum chamber due to the eddy current effect were measured. A circuit to compensate for this effect was then inserted between the signal source and the magnet power supply. The amplitude was restored with an error of less than 20% of the source signal amplitude and the phase shift was reduced from 80{degrees} to 12{degrees} at 10 Hz.
Date: May 30, 1990
Creator: Chung, Y.
Object Type: Report
System: The UNT Digital Library
Initial DAB Argon Storage Dewar Leakage (open access)

Initial DAB Argon Storage Dewar Leakage

Any detectable leakage emanating from the argon storage dewar is undesirable; not only from a safety standpoint (eg, cryogenic burns, asphyxiation, etc.), but also small amounts of air back diffusing through leaks can render the argon unsuitable for the future physics experiments to take place within the cryostats. Whereas leakage through some of the control and manually operated valves on the dewar does not necessarily infroduce any of the above hazards directly, it could be high enough to be an economical, and perhaps an operational nuisance. Contained in the following is a compilation of the final leakage rates associated with the dewar during the period of January through May of 1990 and the raw data from which they were derived from. Also contained is a calculation of the total maximum allowable leakage rate int%ut of the dewar. The general strategy employed while leak checking the dewar was to eliminate all leaks found which could be relatively easily stopped and to reduce the more difficult ones to an acceptable level. Leakage past the seats/plugs of control and main relief valves in addition to leakage past the ball seals in the diverter valve fell into the latter category. Helium mass spectrometer leak …
Date: May 30, 1990
Creator: Dixon, K.
Object Type: Report
System: The UNT Digital Library
Definition of a1 Corrections (open access)

Definition of a1 Corrections

None
Date: May 30, 1990
Creator: H., Hahn & Parzen, G.
Object Type: Report
System: The UNT Digital Library
Hydrothermal pretreatment of coal. [Heat and hydrothermal treatment at 350 degrees C] (open access)

Hydrothermal pretreatment of coal. [Heat and hydrothermal treatment at 350 degrees C]

We recently examined Argonne supplied Wyodak coal under both thermal (no added water, under N{sub 2}) and hydrothermal (liquid water present, under N{sub 2}) conditions at 350{degrees}C for periods of 30 min. and 5 hr. We found that the coal produces a tar that is deposited on the reactor insert walls solely at hydrothermal conditions. The shift from 30 min. to 5 hr. yields a tar that is more volatile and has a slightly increased molecular weight. The coals recovered from thermal and hydrothermal treatments are different by pyrolysis-field ionization mass spectrometry (py-FIMS). Specifically, the hydrothermal condition yields py-FIMS volatiles with a higher weight average molecular weight and greater volatility. They are thus less polar, a conclusion consistent with other py-FIMS data showing that the volatiles from the hydrothermally treated coal are lower in phenolics. Our results show that the phenols and catechols in the coal behave very differently. Our data are consistent with a scheme in which the catechol units in the coal engage in condensation at thermal conditions, probably through a catalyzed process related to acidic sites on the mineral matter. The phenols in contrast are unreactive. At hydrothermal conditions, on the other hand, both are released hydrolytically. …
Date: May 30, 1990
Creator: Ross, David S.
Object Type: Report
System: The UNT Digital Library
Texas Attorney General Opinion: LO90-30 (open access)

Texas Attorney General Opinion: LO90-30

Letter opinion issued by the Office of the Attorney General of Texas in Austin, Texas, providing an interpretation of Texas law. It provides the opinion of the Texas Attorney General, Jim Mattox, regarding a legal question submitted for clarification; Whether the half sister of a school board member may be hired as school cafeteria manager.
Date: May 30, 1990
Creator: Texas. Attorney-General's Office.
Object Type: Text
System: The Portal to Texas History
Design and operation of the electron beam ion trap (open access)

Design and operation of the electron beam ion trap

This report describes the basic features and operating principles of the Electron Beam Ion Trap. The differences between EBIT and other sources of highly charged ions are outlined. Its features and operating parameters are discussed. The report also explains why certain design choices were necessary and the constraints involved in building an electron beam ion trap. EBIT's evaporation cooling system is described in detail. 13 refs., 8 figs.
Date: May 30, 1990
Creator: Vogel, D.
Object Type: Report
System: The UNT Digital Library