Serial/Series Title

Month

DT fusion neutron irradiation of LLL stainless steel tensile specimens, February 23, 1978 (open access)

DT fusion neutron irradiation of LLL stainless steel tensile specimens, February 23, 1978

The DT fusion neutron irradiation of nine LLL stainless steel tensile specimens is described. The sample position, beam-on time and dose record are given. The maximum neutron fluence on any sample was 2.20 x 10/sup 17/ neutrons/cm/sup 2/.
Date: May 17, 1978
Creator: MacLean, S.C.
System: The UNT Digital Library
Fiscal year 1977 DT fusion neutron irradiations and dosimetry at the LLL Rotating Target Neutron Source, October 26, 1977 (open access)

Fiscal year 1977 DT fusion neutron irradiations and dosimetry at the LLL Rotating Target Neutron Source, October 26, 1977

The DT fusion neutron irradiation of 352 samples during 16 irradiation periods (beam-on time of more than 1219 hours) is described. Experiments from 16 individuals representing eight institutions are summarized. Maximum flux in any of the room temperature runs was 9 x 10'' neutrons/cm/sup 2/-sec for an 80 hour irradiation. The number of the UCID dosimetry reports detailing each of the irradiations are given.
Date: May 17, 1978
Creator: MacLean, S.C.
System: The UNT Digital Library
DT fusion neutron irradiation of LLL niobium, March 29, 1978 (open access)

DT fusion neutron irradiation of LLL niobium, March 29, 1978

The DT fusion neutron irradiation of February 13 to 17, 1978 is briefly outlined by the neutron dose record and the neutron fluences on 19 dosimetry foils.
Date: May 17, 1978
Creator: MacLean, S.C.
System: The UNT Digital Library
DT fusion neutron irradiation of LLL NbTi superconductor wires at 4. 2/sup 0/K and University of Oxford Cu/sub 3/Au TEM specimens at room temperature, April 7, 1978 (open access)

DT fusion neutron irradiation of LLL NbTi superconductor wires at 4. 2/sup 0/K and University of Oxford Cu/sub 3/Au TEM specimens at room temperature, April 7, 1978

The DT fusion neutron irradiation of two LLL NbTi superconductor wires at 4.2/sup 0/K and 14 University of Oxford Cu/sub 3/Au TEM specimens at room temperature is described. The sample position, beam-on time, and neutron dose record are given. The results from four profile dosimetry foils measuring the lateral variation in neutron flux are given.
Date: May 17, 1978
Creator: MacLean, S.C.
System: The UNT Digital Library
Integrated system for production of neutronics and photonics calculational constants. Volume 15, Part D, Rev. 1. The LLL Evaluated Nuclear Data Library (ENDL): descriptions of individual evaluations for Z = 0--98 (open access)

Integrated system for production of neutronics and photonics calculational constants. Volume 15, Part D, Rev. 1. The LLL Evaluated Nuclear Data Library (ENDL): descriptions of individual evaluations for Z = 0--98

Descriptions of evaluated nuclear data sets for 86 isotopes in the range Z = 0 to 98 are presented. The evaluation procedures that were used are discussed. At the beginning of the discussion for each individual isotope, a computer-generated listing is given which summarizes the main properties of the data sets that are contained in the evaluation.
Date: May 17, 1978
Creator: Howerton, R.J. & MacGregor, M.H.
System: The UNT Digital Library