Month

Electrolytic Reduction of Uranyl Ion (open access)

Electrolytic Reduction of Uranyl Ion

From introduction: "Due to the hydrogen overvoltage at the surface of a mercury cathode, uranium solutions is hydrochloric acid may be reduced not only to the tetravalent state, but until considerable trivalent uranium is formed. Other metallic ions act as oxidation-reduction catalysts as well as being reduced themselves. The following paper is a study of the various reactions taking place in solution and at the surface of the cathode."
Date: May 27, 1946
Creator: Nichols, Ambrose R., Jr.
System: The UNT Digital Library
The Beta-Gamma Hand and Foot Counters (open access)

The Beta-Gamma Hand and Foot Counters

Abstract: This is basically a counting rate meter, with an alarm circuit, operating from four GM tubes as the detecting elements. The Hand Counter comprises four logarithmic counting rate meters working from four GM tubes mounted individually, with associated electronic circuits, in suitable shields with a metal mesh type of window. Both sides of both hands are sampled simultaneously. In the Foot Counter, two GM tubes are separately and mounted in a suitable mesh window shielded with the electronic circuit; the foot counter uses only two counting rate meters, and both feet are sampled simultaneously. Each circuit is built in two parts; two tubes are in the shield and the balance of the circuit is in the electronic unit which is a standard 17" x 13" chassis. Circuit diagrams are included.
Date: May 1946
Creator: Bradley, W. H.
System: The UNT Digital Library