Thermal Stresses Arising from Defective Strip in Bond (open access)

Thermal Stresses Arising from Defective Strip in Bond

Stresses set up by an insulating strip in the bond are estimated and found to be small compared to those normally present without the defect.
Date: May 18, 1944
Creator: Young, G.
System: The UNT Digital Library
A Case of Rod Warping (open access)

A Case of Rod Warping

Warping of a rod by a variation in heat transfer coefficient around the periphery is considered. Estimates for some simple cases are given, and a more precise numerical calculation is carried out in ne instance.
Date: May 27, 1944
Creator: Murray, F. & Young, Gale Jay
System: The UNT Digital Library
The Diffusion Length of Thermal Neutrons in Uranium (open access)

The Diffusion Length of Thermal Neutrons in Uranium

Measurements made in a uranium cylinder result in a mean value of 1.55 cm. for the diffusion length L for distances of 1 to 4 cm. from the base of the cylinder. Calculations give a value which agrees with the experimental result and show further that L increases from 1.40 to 1.63 cm. as the neutrons diffuse a distance of 5 cm. into the uranium.
Date: May 27, 1944
Creator: Hughes, Donald James, 1915-1960 & Bragdon, E. W.
System: The UNT Digital Library
Determination on Neutron Density With Bismuth Foils : Final Report - Problem Assignment 131 - X21P (open access)

Determination on Neutron Density With Bismuth Foils : Final Report - Problem Assignment 131 - X21P

It is usual to determine the density of neutrons by using foils of metals which become radioactive as a result of bombardment in the region under investigation. From the rate of disintegration of the newly formed radioactive element the number of neutrons absorbed can be calculated. By use of the capture cross section of the element of which the foil is composed the density of the neutrons can then be computed. By counting the alpha particles from a bismuth foil of known weight after exposure to neutrons the density of the neutrons which produced this activity can be calculated. The least accurately known value which enters into this evaluation is the capture cross-section of bismuth for pile neutrons. This value may be improved by future measurements. It is of importance only for absolute measurements of neutron density so that relative values can be measured with considerable accuracy on the basis of known data.
Date: May 30, 1944
Creator: Curtiss, Leon Francis, 1895-
System: The UNT Digital Library