An Experimental Evaluation of the Radiation Protection Afforded by a Large Modern Concrete Office Building (open access)

An Experimental Evaluation of the Radiation Protection Afforded by a Large Modern Concrete Office Building

Abstract: "An experimental study was made to determine the effective shielding provided by a modern reinforced-concrete office building (AEC Headquarters building) from nuclear fallout. Pocket ionization chambers were used for measurement of the radiation-field strength. Fallout was simulated with distributed and point-source configurations of Co-60 and Ir-192 sources. Four typical sections were selected for study, and experiments were performed on each. These included an external wing with exposed basement walls and an external wing with a buried basement. Roof studies were made on an internal wing with a full basement and on the east end of wing A, which has a thin-roof construction. The thick-roof construction of 8 in. of concrete and 2 in. of rigid insulation covers all the building except the east end of wing A, which has 4 in. of concrete and 2 in. of insulation."
Date: May 1, 1959
Creator: Batter, J. F., Jr.; Kaplan, A. L. & Clarke, Eric Thacher
System: The UNT Digital Library