Weldability of Hayes Alloy #25 (open access)

Weldability of Hayes Alloy #25

Technical report describing the process to determine the fusion welding characteristics of Haynes Alloy #25 as applied to TLJ-100530, Corrosion Loops. Hayes Stellite Alloy #25 is a cobalt-base alloy for corrosion resistant high temperature applications. This material, when welded by the inert gas shielded tungsten arc method, produces sound ductile joints. Material thicknesses greater than 12 gauge require standard joint preparations, a V joint being preferred up to 1/4 inch and a U joint for greater thicknesses. Welding heat should be kept to a minimum followed by fast cooling. The molten metal is very fluid and may present difficulties when position welding.
Date: May 19, 1959
Creator: Rogers, S. L.
System: The UNT Digital Library
Description of Purex Plant Process (open access)

Description of Purex Plant Process

Description of Purex plant process for irradiated uranium for the separation and decontamination of plutonium and uranium from each other and from fission products.
Date: May 19, 1959
Creator: Irish, E. R.
System: The UNT Digital Library
Fission Project Yield of Inert Gases (open access)

Fission Project Yield of Inert Gases

The final percentage of xenon created by fission in uranium and plutonium is a function of the neutron flux intensity. The flux dependence results because axenon 133 and 135 can be converted to a a stable xenon isotope by neutron capture instead of decaying into cesium.
Date: May 19, 1959
Creator: Merckx, K. R.
System: The UNT Digital Library
Operation of the HRT Mockup with Boiling Fuel in a Titanium Pressurizer, Run CS-23 (open access)

Operation of the HRT Mockup with Boiling Fuel in a Titanium Pressurizer, Run CS-23

The 0.045m UO2SO4, 0.036m CuSO4, 0.025 m H2SO4 solution (HRT fuel composition) was chemically stable during 1, 866hr of operation at 280ºC and 1500 psi. The system was pressurized by boiling a 0.4 gpm stream of the fuel in a titanium heat exchanger at 313ºC.
Date: May 19, 1959
Creator: Korsmeyer, R. B. & Harley, P. H.
System: The UNT Digital Library
Determination of Thickness of Oxide Film on Phosphor Bronze (open access)

Determination of Thickness of Oxide Film on Phosphor Bronze

The thickness of an oxide film on phosphor bronze helices was determined by first establishing the oxygen content of the helix "as received" and after cleansing with nitric acid. Based on the assumption that the difference between these two values was the oxygen in the film, and that the film consisted entirely of cupric oxide, the thickness of the film was calculated from the density of cupric oxide, weight of the film, and surface area of film. A value of 1080 A was calculated as the thickness by this method.
Date: May 19, 1959
Creator: White, J. C.
System: The UNT Digital Library