Feasibility of In Vivo Plutonium Measurements (open access)

Feasibility of In Vivo Plutonium Measurements

It was shown that without further major development the detectors proposed for the Body Monitor can be expected to detect 0.02 microcurie of plutonium at the center of the chest cavity. This is the permissible body burden of insoluble forms of plutonium. The detection level can be decreased by decreasing the background counting rate. Decreases in the background can reasonably be expected; it should be possible to detect a small fraction of the permissible body burden. If it can be shown, as suggested by other work, that americium will remain with plutonium, then within at least a few months after entry into the body it should be possible to measure the plutonium by detection of rays from Am²⁴¹.
Date: May 14, 1956
Creator: Roesch, W. C. & Baum, J. W.
System: The UNT Digital Library
Final Report: Corrosion of Types 304-L and 347 Stainless Steel by Oxalic Acid (open access)

Final Report: Corrosion of Types 304-L and 347 Stainless Steel by Oxalic Acid

The purpose of this report is to provide data pertaining to the corrosion damage incurred in the use of oxalic acid as a cleaning agent for process equipment.
Date: May 14, 1956
Creator: Walker, W. L.
System: The UNT Digital Library