Texas Attorney General Opinion: JM-692 (open access)

Texas Attorney General Opinion: JM-692

Document issued by the Office of the Attorney General of Texas in Austin, Texas, providing an interpretation of Texas law. It provides the opinion of the Texas Attorney General, Jim Mattox, regarding a legal question submitted for clarification; Authority of a master appointed under the authority of Senate Bill No. 1321, Acts 1985, 69th Leg., ch. 851, ยง1 et seq., at 2951, to handle matters under Title 1, 2 or 4 of the Family Code
Date: May 11, 1987
Creator: Texas. Attorney-General's Office.
Object Type: Text
System: The Portal to Texas History
Flexible Support Stanchion (open access)

Flexible Support Stanchion

Figure 1 shows the assembly drawing of the Central Calorimeter Cryostat Flexible Support Stanchion. Figures 2 and 3 show the Flexible Support STanchion in detail. These Stanchions support the cryostat safely, reduce the heat load to the cryostat from the ambient by a factor of more than ten, provide a spring like action that reduce the loads created by thermal contraction of the cryostat and position the cryostate accurately. Table 1 shows all of the details of the Flexible Support system for the C.C. Cryostat.
Date: May 11, 1987
Creator: Rudland, D. L.
Object Type: Report
System: The UNT Digital Library
Small t Physics at the TEVATRON Collider (open access)

Small t Physics at the TEVATRON Collider

The first physics run of the superconducting Tevatron Collider at Fermilab ended this morning. A status report will be presented on the progress of the small angle elastic scattering and total cross section experiment, E710. The goals of this experiment are to measure the total proton-antiproton cross section from ..sqrt..s = 300 to 2000 GeV, the slope of the diffraction peak and rho, the ratio of the real to imaginary part of the forward scattering amplitude, at these energies. 1 ref., 8 figs.
Date: May 11, 1987
Creator: Bertani, M.; Giacomalli, G.; Maleyran, R.; Manarin, A.; Amos, N.; DeSalvo, R. et al.
Object Type: Article
System: The UNT Digital Library
Summary of x-ray ring performance before the 1987 shutdown (open access)

Summary of x-ray ring performance before the 1987 shutdown

On February 28, 1987, the x-ray ring was shut down for major modifications. 627 Ampere hours of time integrated current had been accumulated and lifetimes of 25 and 9 hours had been routinely achieved at 50 and 200 mA, respectively. This paper summarizes pressure and lifetime behavior since the first bakeout in March 1984, when the lifetime at 20 mA was about 20 minutes.
Date: May 11, 1987
Creator: Halama, H.J.
Object Type: Report
System: The UNT Digital Library