Scale "Up or Down" Analysis for Prototype Test (open access)

Scale "Up or Down" Analysis for Prototype Test

Introduction: In conjunction with the final design and development of a 70 MW sodium intermediate heat exchanger and a sodium steam generator, an analysis is required which can be used as a basis for a determination to scale up or scale down the designs. Included in this analysis are those considerations leading to the recommendation of the best prototype test unit and to some of the limits imposed on scaling up or down when considering future applications of designs other than those actually tested. In addition, these considerations include aspects required to accurately predict the performance, operation, mechanical reliability, and feasibility of fabrication of the 70 MW design.
Date: May 1, 1960
Creator: Alco Products (Firm).
System: The UNT Digital Library
Shielding Requirements for the Army Package Power Reactor (open access)

Shielding Requirements for the Army Package Power Reactor

Abstract. The design, selection, and calculation of the Army Package Power Reactor shielding are described. The APPR-1, a prototype of a package reactor for remote locations, has a primary shield of iron and water. this shield has been adopted to permit fast erection and to provide low transported weight. economically, including transportation cost, the iron water shield is better than a lead water shield and is competitive with a concrete shield for a remote site. Because of the location at Fort Belvoir,Va., the shielding requirements for the APR-1 are considerably more stringent than those for a reactor at a remote base. Since the secondary shielding which surrounds the entire primary system must provide protection for personnel at any location outside the vapor container, concrete is provided for this need.
Date: May 1, 1956
Creator: Meem, J. L. (James Lawrence). & Fairbanks, F. B.
System: The UNT Digital Library