Acceptance test procedure for the L-070 project mechanical equipment and instrumentation (open access)

Acceptance test procedure for the L-070 project mechanical equipment and instrumentation

This document contains the acceptance test procedure for the mechanical equipment and instrumentation installed per the L-070 Project. The specific system to be tested are the pump controls for the 3906 Lift Station and 350-A Lift Station. In addition, verification that signals are being received by the 300 Area Treated Effluent Disposal Facility control system, is also performed.
Date: April 19, 1996
Creator: Loll, C.M.
Object Type: Report
System: The UNT Digital Library
Atmospheric Corrosion of Aluminum Alloy 3105 in Coastal Environments: Interim Report After 15 Months Exposure (open access)

Atmospheric Corrosion of Aluminum Alloy 3105 in Coastal Environments: Interim Report After 15 Months Exposure

In May of 1994, racks of corrosion samples were installed along the Oregon coast. The aluminum alloy 3105 samples were mounted on utility poles in Astoria, Manzanita, Lincoln City, Gold Beach, Brookings, Portland, and Albany. At each coastal location, samples were placed on four different poles at various distances from the coast (from as near as 50 feet to as far as 5 miles). The inland sites (Portland and Albany) have only one pole per site and are used as control sites. Besides the 3105 alloys, 5052 and 6061 aluminum alloys were placed at all sites. Since installation, one rack was lost due to the pole being taken down by the phone company (in Lincoln City), but the rest of the poles and racks are still in place.<br> <br> In August of 1995, the aluminum samples were visually inspected, and the remaining six 3105 aluminum samples in Lincoln City were removed for laboratory examination. Non-destructive x-ray analysis was used on the Lincoln City samples to obtain information a bout the nature of the corrosion products. Because the analysis was performed while the corrosion products remained on the surface, aluminum peaks dominated the diffraction pattern, and relative peak-heights were different from …
Date: April 19, 1996
Creator: Holcomb, G. R.
Object Type: Report
System: The UNT Digital Library
Design and implementation of a CO{sub 2} flood utilizing advanced reservoir characterization and horizontal injection wells in a shallow shelf carbonate approaching waterflood depletion. Technical progress report (open access)

Design and implementation of a CO{sub 2} flood utilizing advanced reservoir characterization and horizontal injection wells in a shallow shelf carbonate approaching waterflood depletion. Technical progress report

The first objective is to utilize reservoir characterization and advanced technologies to optimize the design of a CO{sub 2} project for the South Cowden Unit (SCU) located in Ector County, Texas. The SCU is a mature, relatively small, shallow shelf carbonate unit nearing waterflood depletion. The second objective is to demonstrate the performance and economic viability of the project in the field. This report includes work on the reservoir characterization and project design objective and the demonstration project objective.
Date: April 19, 1996
Creator: Chimahusky, John S.
Object Type: Report
System: The UNT Digital Library
Energy efficient louver and blind. Technical progress report for Quarter 1, 1996 (open access)

Energy efficient louver and blind. Technical progress report for Quarter 1, 1996

This report decribes designs for energy efficient louvers and blinds for windows. The design includes silver and aluminium coated v-grooves.
Date: April 19, 1996
Creator: Khajavi, S.
Object Type: Report
System: The UNT Digital Library
Final characterization and safety screen report of double shell tank 241-AP-104 for 242-A evaporator, campaign 96-1 (open access)

Final characterization and safety screen report of double shell tank 241-AP-104 for 242-A evaporator, campaign 96-1

This data package satisfies the requirement for a format IV, final report. It is a follow-up to the 45-day safety screen report for tank AP-104. Evaporator candidate feed from tank 241-AP-104 (hereafter referred to as AP-104) was characterized for physical, inorganic, organic and radiochemical parameters by the Westinghouse Hanford Company, 222-S Laboratory, and by the Battelle Pacific Northwest National Laboratory (PNNL), Analytical Chemistry Laboratory (ACL) as directed by the Tank Sample and Analysis Plan (TSAP), References 1 through 4. Preliminary data in the form of summary analytical tables were provided to the project in advance of this final report to enable early estimation of evaporator operational parameters, using the Predict modeling program. Laboratory analyses at ACL Laboratory was performed according to the TSAP. Analyses were performed at the 222-S Laboratory as defined and specified in the TSAP and the Laboratory`s Quality Assurance Plan, References 5 and 6. Any deviations from the instructions documented in the TSAP are discussed in this narrative and are supported with additional documentation. SAMPLING The TSAP, section 2, provided sampling information for waste samples collected from tank AP-104. The bottle-on-a-string method was used to collect liquid grab samples from the tank. Each glass sample bottle was …
Date: April 19, 1996
Creator: Miller, G. L.
Object Type: Report
System: The UNT Digital Library
Final report for tank 241-AP-108, grab samples 8AP-96-1, 8AP-96-2 and 8AP-96-FB (open access)

Final report for tank 241-AP-108, grab samples 8AP-96-1, 8AP-96-2 and 8AP-96-FB

This document is the final report deliverable for the tank 241-AP-108 grab samples. The samples were subsampled and analyzed in accordance with the TSAP. Included in this report are the results for the Waste Compatibility analyses, with the exception of DSC and thermogravimetric analysis (TGA) results which were presented in the 45 Day report (Part 2 of this document). The raw data for all analyses, with the exception of DSC and TGA, are also included in this report.
Date: April 19, 1996
Creator: Esch, R.A.
Object Type: Report
System: The UNT Digital Library
High SO{sub 2} removal efficiency testing. Technical progress report, January--March 1996 (open access)

High SO{sub 2} removal efficiency testing. Technical progress report, January--March 1996

This project involves testing at six full-scale utility flue gas desulfurization (FGD) systems, to evaluate low capital cost upgrades that may allow these systems to achieve up to 98% SO{sub 2} removal efficiency. The upgrades being evaluated primarily involve using performance additives in the FGD systems. The base project involved testing at the Tampa Electric Company Big Bend station. All five potential options to the base program have been exercised by DOE, involving testing at Hooiser Energy`s Merom Station (Option I), Southwestern Electric Power Company`s Pirkey Station (Option II), PSI Energy`s Gibson Station (Option III), Duquesne Light`s Elrama Station (Option IV), and New York State Electric and Gas Corporation`s Kintigh Station (Option V). The originally planned testing has been completed for all six sites.
Date: April 19, 1996
Creator: Blythe, G.
Object Type: Report
System: The UNT Digital Library
QA CLASSIFICATION ANALYSIS OF THE STARTER TUNNEL AND SOUTH PORTAL HEADWALL (CI: BABEAA000) (open access)

QA CLASSIFICATION ANALYSIS OF THE STARTER TUNNEL AND SOUTH PORTAL HEADWALL (CI: BABEAA000)

The purpose of this analysis is to determine if the permanent portions of the configuration item BABEAA000 that will be constructed for the Exploratory Studies Facility (ESF) (i.e., Starter Tunnel for the North Portal and the headwall at the South Portal) are quality-affecting items. The objective is to establish the appropriate Quality Assurance (QA) classification based on these determinations. This analysis does not address the remaining scope of the Portals configuration item.
Date: April 19, 1996
Creator: Gwyn, Dealis W.
Object Type: Report
System: The UNT Digital Library
Quarterly environmental radiological survey summary first quarter 1996 100, 200, 300, and 600 areas (open access)

Quarterly environmental radiological survey summary first quarter 1996 100, 200, 300, and 600 areas

This report provides a summary of the radiological surveys performed in support of the operational environmental monitoring program at the Hanford Site. The First Quarter 1996 survey results and the status of actions required from current and past reports are summarized: All the routine environmental radiological surveys scheduled during January, February, and March 1996 were completed. One hundred four environmental radiological surveys were performed during the first quarter of 1996, thirty at the active waste sites and seventy four at the inactive waste sites. Contamination above background levels was found at six of the active waste sites and eight of the inactive waste sites. Contamination levels as high as > 1,000,000 disintegrations per minute (dpm) were reported. Of these contaminated surveys, all were in Underground Radioactive Material (URM) areas. The contamination found within eleven of the URH areas was immediately cleaned up and no further action was required. In the remaining three sites the areas were posted and will require decontamination. Radiological Problem Reports (RPR`s) were issued and the sites were turned over to the landlord for further action if required.
Date: April 19, 1996
Creator: Dorian, J. J.
Object Type: Report
System: The UNT Digital Library
State Eleventh Amendment Sovereign Immunity: Seminole Tribe v. Florida, 116 S.Ct. 1114 (1996) (open access)

State Eleventh Amendment Sovereign Immunity: Seminole Tribe v. Florida, 116 S.Ct. 1114 (1996)

None
Date: April 19, 1996
Creator: unknown
Object Type: Report
System: The UNT Digital Library
Texas Attorney General Opinion: DM-384 (open access)

Texas Attorney General Opinion: DM-384

Document issued by the Office of the Attorney General of Texas in Austin, Texas, providing an interpretation of Texas law. It provides the opinion of the Texas Attorney General, Dan Morales, regarding a legal question submitted for clarification; Whether sections 1.045 and 1.07(a)(1) of the Family Code, requiring an applicant for a marriage license to state under oath that he or she does not owe delinquent court-ordered child support, violate the Equal Protection Clause of the Fourth Amendment to the United States Constitution (RQ-862)
Date: April 19, 1996
Creator: Texas. Attorney-General's Office.
Object Type: Text
System: The Portal to Texas History
Texas Attorney General Opinion: DM-385 (open access)

Texas Attorney General Opinion: DM-385

Document issued by the Office of the Attorney General of Texas in Austin, Texas, providing an interpretation of Texas law. It provides the opinion of the Texas Attorney General, Dan Morales, regarding a legal question submitted for clarification; Whether a deputy constable may be classified as an "employee" pursuant to chapter 158 of the Local Government Code (RQ-848)
Date: April 19, 1996
Creator: Texas. Attorney-General's Office.
Object Type: Text
System: The Portal to Texas History
Texas Register, Volume 21, Number 28, Pages 3399-3478, April 19, 1996 (open access)

Texas Register, Volume 21, Number 28, Pages 3399-3478, April 19, 1996

A weekly publication, the Texas Register serves as the journal of state agency rulemaking for Texas. Information published in the Texas Register includes proposed, adopted, withdrawn and emergency rule actions, notices of state agency review of agency rules, governor's appointments, attorney general opinions, and miscellaneous documents such as requests for proposals. After adoption, these rulemaking actions are codified into the Texas Administrative Code.
Date: April 19, 1996
Creator: Texas. Secretary of State.
Object Type: Journal/Magazine/Newsletter
System: The Portal to Texas History
Waste Receiving and Processing Facility Module 1 Data Management System software requirements specification (open access)

Waste Receiving and Processing Facility Module 1 Data Management System software requirements specification

This document provides the software requirements for Waste Receiving and Processing (WRAP) Module 1 Data Management System (DMS). The DMS is one of the plant computer systems for the new WRAP 1 facility (Project W-0126). The DMS will collect, store and report data required to certify the low level waste (LLW) and transuranic (TRU) waste items processed at WRAP 1 as acceptable for shipment, storage, or disposal.
Date: April 19, 1996
Creator: Rosnick, C.K.
Object Type: Report
System: The UNT Digital Library