Input Impedance of a Probe Antenna Exciting a TEM Cell (open access)

Input Impedance of a Probe Antenna Exciting a TEM Cell

Abstract: The input impedance of a probe antenna exciting a transverse electromagnetic (TEM) transmission line cell is formulated by a variational approach. The formulation also utilizes the results from a previous work on the field distribution inside a TEM cell excited by a vertical electrical Hertzian dipole. The final result of imoedance is shown to consist of two distinct terms, which are respectively contributed by the ordinary rectangular waveguide and the gap perturbation. Numerical results for both the real and imaginary parts of the impedance are given. The resistive part is found to be proportional to the square of the probe length, and the reactive part largely capacitive.
Date: April 1982
Creator: Wilson, Perry F.; Chang, David C. & Ma, Mark T.
System: The UNT Digital Library
An Electric and Magnetic Field Sensor for Simultaneous Electromagnetic Near-Field Measurements -- Theory (open access)

An Electric and Magnetic Field Sensor for Simultaneous Electromagnetic Near-Field Measurements -- Theory

Abstract: This paper describes the theory of a single sensor to perform simultaneous electric and magnetic near-field measurements. The theory indicates that it is possible to obtain the magnetic-loop and electric-dipole currents using a loop terminated with identical loads at diametrically opposite points. The theory also indicates that it is possible to obtain an ideal load impedance for achieving equal electric and magnetic field responses of the loop. Preliminary experiments have been performed using plane waves to verify these results. Key words: electric field, electromagnetic interference, electromagnetic radiation, loop, magnetic field, near fields.
Date: April 1983
Creator: Kanda, Motohisa
System: The UNT Digital Library
Cryogenic Fluids Density Reference System: Provisional Accuracy Statement (1980) (open access)

Cryogenic Fluids Density Reference System: Provisional Accuracy Statement (1980)

Abstract: The improved Density Reference System, the reference densimeter, and the method of determining sample density are described. The uncertainty of the density reference system is + 0.055%. The contribution from the estimated systema -ic error in density was + 0.022%. The estimated uncertainty caused by random error is three times the standard deviation of 0.011% and is based on sixty-three measurements of the densities of saturated liquid methane. The total density uncertainty is taken to be the sum of the systematic and random errors. This applies to the density range of 400 to 480 kg/m at pressures from 0.8 to 4 bar absolute and temperatures between 109 and 128 K. This accuracy statement is expected to apply over ranges of at least 400 to 1000 kg/m3 in density, 77 to 300 K in temperature, and 0.8 to 7 bar in pressure though the accuracy over these ranges has not been verified.
Date: April 1981
Creator: Siegwarth, J. D. & LaBrecque, J. F.
System: The UNT Digital Library
Basic Tables for Chemical Analysis (open access)

Basic Tables for Chemical Analysis

Abstract: Tables of important data for use in the analytical chemistry laboratory are provided. These tables contain information for use in gas chromatography, liquid chromatography, infrared and ultraviolet spectrophotometry, mass spectrometry, and wet chemical techniques. Tables relating to safe practice in the analytical laboratory are also included.
Date: April 1986
Creator: Bruno, Thomas J. & Svoronos, Paris D. N.
System: The UNT Digital Library
Design, Evaluation, and Use of a Reverberation Chamber for Performing Electromagnetic Susceptibility/Vulnerability Measurements (open access)

Design, Evaluation, and Use of a Reverberation Chamber for Performing Electromagnetic Susceptibility/Vulnerability Measurements

Abstract: This report presents the results of work at the National Bureau of Standards, Boulder, Colorado, to carefully evaluate, document, develop (when necessary), and describe the methodology for performing radiated susceptibility/vulnerability measurements using a reverberation chamber. The report describes the reverberation chamber theory of operation, construction, evaluation, functional operation, and use for performing immunity measurements. It includes an estimate of measurement uncertainties derived empirically from test results and from comparisons with anechoic chamber measurements. Finally, it discusses the limitations and advantages of the measurement technique to assist potential users in determining the applicability for this technique to their electromagnetic compatibility (EMC) measurement needs.
Date: April 1986
Creator: Crawford, M. L. & Koepke, Galen H.
System: The UNT Digital Library
VOR Calibration Services (open access)

VOR Calibration Services

from Introduction: The National Bureau of Standards has designed, constructed, and evaluated a standard for the support of very-high-frequency omnidirectional range (VOR) air navigation aids. The standard consists of two instruments: (1) a digital waveform signal generator for the composite VOR audio waveform, and (2) a standard phasemeter based on time series analysis of this waveform. Experimental results, a statistical analysis of them, and the principal software listings are included.
Date: April 1985
Creator: Larsen, Neil T.; Vecchia, Dominic F. & Sugar, George R.
System: The UNT Digital Library
Recommended Practice for the Use of Metric (SI) Units in Building Design and Construction (open access)

Recommended Practice for the Use of Metric (SI) Units in Building Design and Construction

Report issued by the U.S. National Bureau of Standards discussing the use of metric units of measurement during construction. As stated in the scope, "this document outlines a selection of SI units, with multiples and sub-multiples, for general use in building design and construction" (p. 1). This report includes tables, and illustrations.
Date: April 1977
Creator: Milton, Hans J.
System: The UNT Digital Library