Transistor Pre-Amplifier for Neutron Monitors (open access)

Transistor Pre-Amplifier for Neutron Monitors

In the past several years the use of neutron monitors for Pu concentration monitoring has been expanded in the Chemical Processing Department. Most of these monitors have been quite successful, and considerable effort is being made to improve the operation of both existing and future monitoring systems. One of the major improvements has been the development and use of a transistorized pre-amplifier or impedance matching circuits. This unit solves several problems associated with the use of boron trifluoride (BF3) neutron detectors in process monitoring; e.g., vacuum tube pre-amp failure because heat is not being conducted away.
Date: April 20, 1960
Creator: Kelly, P. R.
System: The UNT Digital Library
An Automatic Water Deaeration System (open access)

An Automatic Water Deaeration System

Laboratory studies involving fluid flow through porous media require use of fluids having low dissolved gas content. Water is the major fluid used in various and box model and soil permeability studies carried out by the Geochemical and Geophysical Research group. Tap water supplied to the 222-U Bldg. contains a large amount of dissolved air. Under the reduced pressure encountered during model studies, the air is released from solution and gradually clogs the pores of the sand or other porous material. This, of course. leads to anomalous results and cannot be tolerated in precious studies. A system was required to effectively remove the air and make available a continuous supply of desired water for the model studies.
Date: April 20, 1959
Creator: Raymond, J. R.
System: The UNT Digital Library
Corrosion of 2R-2 and 304 Stainless Steel Following the Turco-4501 Decontamination Process. (open access)

Corrosion of 2R-2 and 304 Stainless Steel Following the Turco-4501 Decontamination Process.

The build up of contaminated film on the internal surfaces of high temperature in-reactor recirculating water loops has created serious radiation exposure problems to operational and maintenance personnel. A considerable amount of work has been applied to develop an effective decontamination process for the decontamination of these loops and their components.
Date: April 20, 1959
Creator: Larrick, A. P. & Lotsinger, R. J.
System: The UNT Digital Library
PRTR Gas-Cooled Loop, Hazards Survey of Preliminary Scope Design (open access)

PRTR Gas-Cooled Loop, Hazards Survey of Preliminary Scope Design

The Atomic Energy Commission has recently developed an enlarged program for the study of graphite moderated, gas cooled power reactor systems. It has been recognized, however, that understanding of radiation damage and radiation induced chemical reactions of graphite at the proposed high moderator temperatures is inadequate and that improved understanding is essential if the design of such reactors is to be optimized. Accordingly, the Atomic Energy Commission requested Hanford to organize a modest research and development program directed toward the study of these graphite problems.
Date: April 20, 1959
Creator: Wittenbrock, N. G.
System: The UNT Digital Library
Ground Level Concentrations in the Vicinity of a 185 ft Stack (open access)

Ground Level Concentrations in the Vicinity of a 185 ft Stack

Field tests were conducted to measure short-period pollutant concentrations at several stack heights during conditions of marked atmospheric instability and low wind speeds. The source was a mechanical smoke generator located at the 185-ft level of a tower.
Date: April 20, 1953
Creator: Shorr, B.
System: The UNT Digital Library
The Determination of Uranyl Nitrate in Pretreated Hexone by Infrared Absorption Measurements (open access)

The Determination of Uranyl Nitrate in Pretreated Hexone by Infrared Absorption Measurements

The following report examines methods to determine uranium nitrate hexahydrate on pretreated hexone in the range of 0 to 40 g./l. by infrared absorption measurements.
Date: April 20, 1950
Creator: Moore, R. H.
System: The UNT Digital Library
Ferrous Sulfamate Stability in the RA System (open access)

Ferrous Sulfamate Stability in the RA System

Objective: "The observations summarized in the present report were made to determine the stability of ferrous and sulfamate ions and sulfamic acid in RA Column scrub solution (RAS) and in aqueous solution comparable to the RA Column feed tee composition (RAFS). Knowledge of the stability of the reducing agent (ferrous iron) is necessary to properly plan the method of preparation and introduction of this component into the RA system and to assure dependable and reproducible performance."
Date: April 20, 1950
Creator: Clagett, Fred
System: The UNT Digital Library