"25" Critically Consultation with J. W. Morfitt : April 3, 1950 (open access)

"25" Critically Consultation with J. W. Morfitt : April 3, 1950

Summary: "Criticality was considered impossible in any contingency encountered in practice under either of the following conditions which include no safety factor: (a) In any isolated cylinder not more than 5 in. in disruptor, if the total amount of U235 present does not exceed 7.5 Eg. (b) In an isolated vessel of any shape and size, if the total amount of U235 present does not exceed 880 g. An "isolated" vessel is one which does not "see" more than 0.1 [...] other vessels containing fissionable material."
Date: April 3, 1950
Creator: Merrill, E. T. & Sege, G.
System: The UNT Digital Library
The Use of Laboratory High Frequency Induction Furnaces (open access)

The Use of Laboratory High Frequency Induction Furnaces

Equations are derived for the rates of heating of objects in induction furnaces and for the maximum temperatures attainable. The equations are primarily useful in designing conducting crucibles, shells, and cylinders so as to increase the power input and decrease heat losses. A very brief treatment is given of the factors which influence the current in the induction coil. The performances of various induction furnaces are compared.
Date: April 3, 1950
Creator: Brewer, Leo, 1919-2005
System: The UNT Digital Library