Design of Extensometer for Creep Studies: Special Progress Report (open access)

Design of Extensometer for Creep Studies: Special Progress Report

None
Date: February 1, 1953
Creator: Gossick, B. R.
System: The UNT Digital Library
SUMMARY OF JOURNAL BEARING TESTS WITH COPPER BEARINGS AND TUNGSTEN CARBIDE JOURNALS OPERATING IN SODIUM-POTASSIUM ALLOY (open access)
CHEMISTRY DIVISION, SECTION C-I QUARTERLY REPORT FOR OCTOBER, NOVEMBER, AND DECEMBER 1952 (open access)

CHEMISTRY DIVISION, SECTION C-I QUARTERLY REPORT FOR OCTOBER, NOVEMBER, AND DECEMBER 1952

None
Date: February 1, 1953
Creator: Osborne, D.W. ed.
System: The UNT Digital Library
Progress Report No. 3 on Radiation Damage and Recovery . Progress Report No. 3 (open access)

Progress Report No. 3 on Radiation Damage and Recovery . Progress Report No. 3

None
Date: February 1, 1953
Creator: Koehler, J. S.
System: The UNT Digital Library
BASIC OPERATIONAL REPORT OF THE ARGONNE ACTIVE WASTE INCINERATOR (open access)

BASIC OPERATIONAL REPORT OF THE ARGONNE ACTIVE WASTE INCINERATOR

None
Date: February 1, 1953
Creator: Hampson, D.C.; Hykan, E.H. & Rodger, W.A.
System: The UNT Digital Library
Dynamics of the Supercritical Water Reactor (open access)

Dynamics of the Supercritical Water Reactor

From introduction: "The work described in this report was carried out as part of the feasibility study (ORNL-117) of a supercritical water reactor (SCWR) for use in nuclear propulsion of aircraft. The object of this work was to study the dynamic behavior of a particular design of supercritical water reactor. Numerical results are presented in Appendix I."
Date: February 1, 1953
Creator: Goertzel, Gerald, 1919-; Shapiro, Mathew M. & Soodak, Harry
System: The UNT Digital Library
The Determination of Oxygen in Plutonium by the Capillary Trap Method (open access)

The Determination of Oxygen in Plutonium by the Capillary Trap Method

A new method for the determination of O/sub 2/ in metals is described. The sample is dropped into molten Pt in a graphite crucible. The oxide in the sample reacts with C to form CO, which is swept out by a stream of argon at atmospheric pressure. The CO is oxidized to CO/sub 2/, which is condensed in a capillary trap and measured with a capillary manometer. The apparatus is sensitive to 0.3 mu g of O/sub 2/, and routine 50-mg Pu samples give a standard deviation of 7 ppm or 0.35 mu g. Pu samples with added O/sub 2/ gave a standard deviation of 1.5 mu g or 2% of the total oxygen, with no significant bias. The apparatus is simple and rugged permitting replacement of parts without glassblowing. The speed is superior to vacuum fusion methods, most samples requiring only twelve minutes for analysis.
Date: February 1, 1953
Creator: Smiley, William G. (William Gooding), 1915-
System: The UNT Digital Library
Chemistry Division Section C-1 Quarterly Report, October, November, And December 1952 (open access)

Chemistry Division Section C-1 Quarterly Report, October, November, And December 1952

Report describing the research and development activities related to nuclear chemistry and radiochemistry and basic chemistry conducted by the Argonne National Laboratory Chemistry Division, Section C-1.
Date: February 1, 1953
Creator: Manning, W. M. & Osborne, D. W.
System: The UNT Digital Library