Shallow Ground Water in the Boulder-Fort Collins-Greeley Area, Front Range Urban Corridor, Colorado, 1975-77 (open access)

Shallow Ground Water in the Boulder-Fort Collins-Greeley Area, Front Range Urban Corridor, Colorado, 1975-77

From introduction: This investigation was made as part of a comprehensive geohydrologic study of the Front Range Urban Corridor in Colorado conducted by the U.S. Geological Survey. The purpose of the study was to delineate the areal extent of the aquifer, the altitude and configuration of the water table, and the gradient and underflow in various parts of the area, in order to better understand the quality of water moving into and through the aquifer.
Date: 1983
Creator: Schneider, Paul A., Jr.
Object Type: Report
System: The UNT Digital Library
Technical Progress Report, November 1, 1979-October 31, 1980. Report Npl-865. [Univ. Of Colorado] (open access)

Technical Progress Report, November 1, 1979-October 31, 1980. Report Npl-865. [Univ. Of Colorado]

Work carried out at the Nuclear Physics Laboratory of the University of Colorado from November 1, 1979 through October 31, 1980 is summarized. Emphasis was on light ion reaction studies with the AVF cyclotron. The high resolution magnetic spectrometer has allowed studies of nucleon transfer, scattering, and charge exchange reactions throughout the periodic table. More experiments have been run with solid state counters this year than has been the case recently, as a broad range spectra of the light nuclei where only moderate resolution is demanded were examined. Several of these experiments were undertaken for more detailed studies of excitations seen with higher energy probes. Multiple coincidence measurements with neutron and gamma-ray counters have opened a new program in pre-equilibrium reactions and provided a new signature for the study of neutron-deficient final nuclei. The neutron time of flight program has expanded to higher excitation and to use of the (d,n) and (..cap alpha..,n) direct nucleon transfer reactions. Three important experiments were completed at the EPICS pion scattering facility at LAMPF, and other low energy pion scattering data were obtained at TRIUMF. Several (p,d) runs at high energies were accomplished, some with polarized beams at TRIUMF. High-lying structures in medium mass …
Date: November 1, 1980
Creator: unknown
Object Type: Report
System: The UNT Digital Library
Numerical Calculation of the Three Dimensional Electrical Field in the Central Region of a Cyclotron (open access)

Numerical Calculation of the Three Dimensional Electrical Field in the Central Region of a Cyclotron

To provide detailed and accurate electric fields in the ion source-puller region and at the dee dummy-dee gap for a cyclotron, a relaxation method solution of Laplace's equation has been used. A conventional difference equation with variation in mesh size and relaxation factor as well as different schemes for boundary corrections have been developed to achieve roughly 1 percent accuracy for a thre-dimensional domain with 10/sup 6/ mesh points. Although the computation requires considerable computer time, it is much less expensive than electrolytic tank analogue methods for measuring field distributions around complex electrode configurations.
Date: January 1, 1981
Creator: Chen, M. & Lind, D. A.
Object Type: Article
System: The UNT Digital Library