Spectrographic Analysis of Normal Human Tissue from Dallas, Texas (open access)

Spectrographic Analysis of Normal Human Tissue from Dallas, Texas

All tissues included in this report were received from Dallas, Texas and were collected, ashed and analyzed according to the methods described in ORNL-CF-57-2-2. The average value of the concentration for each element in a tissue is the average of the concentrations in only those samples of the tissue which contained the element. For example, if, of 25 lives analyzed, only 10 contained lead, the average for lead in liver is the average of those 10 values. For those tissues in which an element does not appear in every sample, the lowest value is reported as less than the limit of sensitivity of the method for that element in that tissue. For the elements, lithium and rubidium, the ash was a composited ash sample for each particular tissue. As an example, in lieu of analyzing 20 individual aortas, only on composited aorta as was analyzed.
Date: February 26, 1957
Creator: Tipton, I. H.; Cook, M. J.; Steiner, R. L.; Foland, J. M.; McDaniel, K. K. & Fentress, S. D.
System: The UNT Digital Library
Source of Fission Products in LITR Cooling Water (open access)

Source of Fission Products in LITR Cooling Water

A study has been made of the radioactive nuclides present in the cooling water of the Low Intensity Test Reactor. Prominent nuclides which have been identified include Np239 and certain fission products. The experimental evidence points to the probability that there could be adequate U235 contamination on the fuel plates to quantitatively account for the fission products identified in the LITR cooling water. inasmuch as new aluminum does not contain uranium, it must be assumed that the contamination occurs during the fabrication of the fuel elements.
Date: March 26, 1957
Creator: Moeller, D. W. (Dade W.) & Leddicotte, G. W.
System: The UNT Digital Library
Temperature Effects on the Measurement of Aqueous Liquid Level by the Differential Pressure Method and Recommendations for Placement of Taps on the HRT Replacement Heat Exchanger (open access)

Temperature Effects on the Measurement of Aqueous Liquid Level by the Differential Pressure Method and Recommendations for Placement of Taps on the HRT Replacement Heat Exchanger

Increasing temperature in an aqueous liquid system results in a decrease in liquid density and an increase in vapor density. When level is measured by the differential pressure method, temperature increase results in a decrease in the effective span f the instrument and a shift in zero. When the instrument reference leg is uncompensated, both zero and span shifts occur with the effects being most pronounced at the high levels. When the reference leg is compensated, zero shifts are eliminated (instrument zero is at 100% level for this type installation). For control purposes at levels above 50% of full level, the compensated reference leg installation will give the best results. For measurement of levels below 50%, the uncompensated installation is best. As errors in level indications will be produced, in either type installation, by temperature, pressure and steam withdrawal (power) effects, the placement of taps should be such as to place the normal or control level in the region of 50% indicated level.
Date: April 26, 1957
Creator: Moore, R. L.
System: The UNT Digital Library
Time Behavior of Fuel Concentrations in Single-Region Reactors Containing U-233, U235, Th-232 and Fission Product Poisons (open access)

Time Behavior of Fuel Concentrations in Single-Region Reactors Containing U-233, U235, Th-232 and Fission Product Poisons

Analytical expressions were obtained for the time behavior of fuel concentrations and fuel-feed rates in single-region, spherical, UO3-ThO2-D2O reactors.
Date: February 26, 1957
Creator: Gilbert, Nathan & Kasten, Paul R.
System: The UNT Digital Library