Control Rod Positions for Criticality. Section I. 5032-EFPN. Eigth Performance. Core I, Seed 1. Test Results DL-S-149, T-550130 (open access)

Control Rod Positions for Criticality. Section I. 5032-EFPN. Eigth Performance. Core I, Seed 1. Test Results DL-S-149, T-550130

The purpose of the test was to determine critical bank heights and bank worths for various rod configurations at ambient temperatures. The critical rod bank position and bank worths for four different control rod bank rod configuration were determined after 5032 EFPH's of operation. The value were corrected to a reactor coolant temperature of 145 F and a pressure of 400 psig. The bank worths were corrected to 145 F so that the results of the performance could be compared with the results of previous performances.
Date: December 9, 1959
Creator: McTish, James M.
System: The UNT Digital Library
The Use of an Electronic High Vacuum Pump on Various Types of Mass Spectrometers (open access)

The Use of an Electronic High Vacuum Pump on Various Types of Mass Spectrometers

A commercially available electronic high vacuum pump has bee tested on various types of mass spectrometers used at the Oak Ridge Gaseous Diffusion Plant. Considerable savings in operating and maintenance costs can be realized from the use of this pump. the greatest savings result from the elimination of the cold trap required for the diffusion pump whether it is cooled by liquid nitrogen or by mechanical refrigeration. additional savings results from the fact that the pump currently is usually an adequate indication of the pressure in the spectrometer tube and that a continuously running mechanical fore pump is not required.
Date: October 9, 1959
Creator: High, R. D. & Schede, R. W.
System: The UNT Digital Library
Periodic Intercalibration of Temperature Sensing Elements. Section I. Second Performance. Test Results DL-S-243 (T-641303) (open access)

Periodic Intercalibration of Temperature Sensing Elements. Section I. Second Performance. Test Results DL-S-243 (T-641303)

The purpose of the test was to determine the direction and magnitude of any drift in the temperature sensing elements and the receiver-indicating units for the primary loop and pressurizer resistance thermometers. To obtain intercalibration data for various temperature sensing elements in the primary coolant system. To obtain data on the difference between the calculated signal generated by the BF-3 counters, considering the known rate of decay of the PO-BE source, and the measured values. Of the 62 core thermocouples observed 19 were either reading less than 400 F or were reading in excess of 20 F from the calibrating thermometer temperatures. In each case the thermocouple was considered defective. The remainder were within 2 per cent of the calibrating thermometers. The primary loop (Norwood Indicators) resistance thermometers all read with 0.2 percent of the calibrating thermometers. No conclusion could be made for the pressurizer temperature instruments or the boiler Tb resistance thermometers, except that the 1A boiler temperature varied 10 F to 20 F from the 1Band 1C boiler temperatures. A laboratory calibration of this instrument will be made. The data obtained from the source range nuclear instrumentation was too erratic to form any conclusion. No drift evaluation on …
Date: November 9, 1959
Creator: Lawrence, Roger J.
System: The UNT Digital Library
Periodic Intercalibration of Temperature Sensing Elements. Section I. First Performance. Test Results DL-S-243 (T-641306) (open access)

Periodic Intercalibration of Temperature Sensing Elements. Section I. First Performance. Test Results DL-S-243 (T-641306)

The purpose of the test was to determine the direction and magnitude of any drift in the temperature sensing elements and the receiver-indicating units for the primary loop and pressurizer resistance thermometers. To obtain intercalibration data for various temperature sensing elements in the primary coolant system. To obtain data on the difference between the calculated signal generated by the BF-3 counters, considering the known rate of decay of the PO-BE source, and the measured values. Determination of temperature sensing element and instrumentation drifts could not be made due to a lack of comparative data. Five temperature intercalibrations were performed using the calibrating Tc resistance thermometers as a standard. The data obtained from the nuclear instrumentation was too erratic to form any conclusions.
Date: November 9, 1959
Creator: Lawrence, Roger J.
System: The UNT Digital Library
Higher harmonics of Radial Vibrations in Short Hollow Cylinders of Barium Titanate (open access)

Higher harmonics of Radial Vibrations in Short Hollow Cylinders of Barium Titanate

This paper discusses the forbidden and allowed harmonics of a hollow cylinder of barium titanate vibrating in the radial mode.
Date: March 9, 1955
Creator: Stephenson, C.V.
System: The UNT Digital Library
Line Broadening by Electrons : the Validity of Simple Theories (open access)

Line Broadening by Electrons : the Validity of Simple Theories

A comparison of the simple impact theories of line broadening by electrons with the detailed computations of Kivel, Bloom, and Margenau.
Date: May 9, 1955
Creator: Meyerott, Roland Edward & Margenau, Henry, 1901-1997.
System: The UNT Digital Library