Response to requests by FMF and DWPF concerning disposal of FMF saltstone drums in Z-Area vaults (open access)

Response to requests by FMF and DWPF concerning disposal of FMF saltstone drums in Z-Area vaults

Disposal of FMF saltstone in 55 gallon drums in the Z-Area Industrial Waste Landfill requires modification of the landfill permit. Approximately 5000 drums of FMF saltstone are currently stored on SC DHEC-permitted concrete storage pads adjacent to the burial ground. At a meeting with DWPF, FMF, and EPS on July 18, 1989, IWT agreed to supply the following information: (1) Consequence of disposal of CCA (Cu, Cr, As) treated wood pallets in the Z-Area vaults. (Four drums of FMF saltstone are currently banded to each pallet.) (2) Consequence of placing partially filled FMF drums in the Z-Area vaults. (3) Formulation for clean grout back-fill. Grout will be emplaced around and over the drums, thereby isolating them from environment (rainwater) prior to vault capping. (4) Maximum loading of FMF saltstone drums in the Z-Area vaults. (5) Consequence of void volume in drums, in clean grout, or both on groundwater modeling results. This document is a response to the above requests.
Date: July 25, 1989
Creator: Langton, C. A. & Cook, J. R.
Object Type: Report
System: The UNT Digital Library
Response to requests by FMF and DWPF concerning disposal of FMF saltstone drums in Z-Area vaults (open access)

Response to requests by FMF and DWPF concerning disposal of FMF saltstone drums in Z-Area vaults

Disposal of FMF saltstone in 55 gallon drums in the Z-Area Industrial Waste Landfill requires modification of the landfill permit. Approximately 5000 drums of FMF saltstone are currently stored on SC DHEC-permitted concrete storage pads adjacent to the burial ground. At a meeting with DWPF, FMF, and EPS on July 18, 1989, IWT agreed to supply the following information: (1) Consequence of disposal of CCA (Cu, Cr, As) treated wood pallets in the Z-Area vaults. (Four drums of FMF saltstone are currently banded to each pallet.) (2) Consequence of placing partially filled FMF drums in the Z-Area vaults. (3) Formulation for clean grout back-fill. Grout will be emplaced around and over the drums, thereby isolating them from environment (rainwater) prior to vault capping. (4) Maximum loading of FMF saltstone drums in the Z-Area vaults. (5) Consequence of void volume in drums, in clean grout, or both on groundwater modeling results. This document is a response to the above requests.
Date: July 25, 1989
Creator: Langton, C. A. & Cook, J. R.
Object Type: Report
System: The UNT Digital Library
Texas Register, Volume 14, Number 54, Pages 3553-3587, July 25, 1989 (open access)

Texas Register, Volume 14, Number 54, Pages 3553-3587, July 25, 1989

A weekly publication, the Texas Register serves as the journal of state agency rulemaking for Texas. Information published in the Texas Register includes proposed, adopted, withdrawn and emergency rule actions, notices of state agency review of agency rules, governor's appointments, attorney general opinions, and miscellaneous documents such as requests for proposals. After adoption, these rulemaking actions are codified into the Texas Administrative Code.
Date: July 25, 1989
Creator: Texas. Secretary of State.
Object Type: Journal/Magazine/Newsletter
System: The Portal to Texas History