A high resolution scale-of-four (open access)

A high resolution scale-of-four

A high resolution scale-of-four has been developed to be used in conjunction with the nuclear particle detection devices in applications where the counting rate is unusually high. Specifically, it is intended to preceed the commercially available medium resolution scaling circuits and so decrease the resolving time of the counting system. The circuit will function reliably on continuously recurring pulses separated by less than 0.1 μ sec. It will resolve two pulses (occuring at a moderate repetition rate) which are spaced at 0.04 μ sec. A five-volt input signal is sufficient to actuate the device.
Date: August 25, 1949
Creator: Fitch, V.
System: The UNT Digital Library
Performance of Single-Stage Turbine of Mark 25 Torpedo Power Plant with Two Special Nozzles 2 - Efficiency with 20 Degrees-Inlet-Angle Rotor Blades (open access)

Performance of Single-Stage Turbine of Mark 25 Torpedo Power Plant with Two Special Nozzles 2 - Efficiency with 20 Degrees-Inlet-Angle Rotor Blades

"A single-stage modification of the turbine from a Mark 25 torpedo power plant was investigated to determine the performance with two nozzle designs in combination with special rotor blades having a 20 inlet angle. The performance is presented in terms of blade, rotor, and brake efficiency as a function of blade-jet speed ratio for pressure ratios of 8, 15 (design), and 20. The blade efficiency with the nozzle having circular pas- sages (K) was equal to or higher than that with the nozzle having rectangular passages (J) for all pressure ratios and speeds investigated" (p. 1).
Date: August 25, 1949
Creator: Schum, Harold J. & Whitney, Warren J.
System: The UNT Digital Library