Fabrication of Uranium Wire (open access)

Fabrication of Uranium Wire

From abstract: "The present report describes experimental work performed to establish a procedure for the production of uranium metal wire. In all cases, the size of the initial rod was 1/2 inch diameter. Three materials were used: hot extruded tuballoy rod, high purity cast tuballoy rod, and cast U-235 rod."
Date: October 25, 1949
Creator: Anderson, R. E.; Taub, J. M. & Doll, D. T.
System: The UNT Digital Library
A Modification of the Norelco Diffractometer for the Identification of Phases in Metallographic Specimens (open access)

A Modification of the Norelco Diffractometer for the Identification of Phases in Metallographic Specimens

A modification of the specimen support for the Norelco diffractometer permits X-ray diffraction studies to be made of specimens prepared for metallographic examination. The unit has been successfully used to identify phases present in specimens of plutonium-uranium alloys.
Date: February 25, 1952
Creator: Stambaugh, C. K. & Whyte, D. D.
System: The UNT Digital Library
The Polarographic Determination of Uranium in the Presence of Plutonium (open access)

The Polarographic Determination of Uranium in the Presence of Plutonium

Strubl's polarographic method for the determination of uranium in the presence of iron can be used for the determination of uranium in plutonium solutions. A hydroxylamine hydrochloride solution (2M) is used as the supporting electrolyte. This reduces the plutonium to the plus three oxidation state without reducing the uranium. The uranium may then be determined polarographically by measuring the height of the uranyl reduction wave (UVI to UV) at -0.35 volts (vs. S.C.E.) applied potential. Solutions with a U/Pu weight ratio as low as 3.5 x 10(-3) were analyzed with an error of less than 2%. This error increased to 6% for solutions of 1 x 10(-3) U/Pu ration and is considerably larger for smaller U/Pu ratios.
Date: May 25, 1951
Creator: Smith, Maynard E. (Maynard Elliott)
System: The UNT Digital Library
Calcium Oxalate Carrier Precipitation of Pu (open access)

Calcium Oxalate Carrier Precipitation of Pu

This technical report describes a plant-scale procedure for concentrating plutonium and americium in slag and crucible (metal reduction residues) and other recovery solutions by a calcium oxalate carrier precipitation Conclusions from exploratory laboratory tests on the variables affecting the efficiency are included.
Date: February 25, 1954
Creator: Maraman, W. J.
System: The UNT Digital Library