Detection of volatile organic compounds using surface enhanced Raman scattering (open access)

Detection of volatile organic compounds using surface enhanced Raman scattering

The authors present the detection of volatile organic compounds directly in their vapor phase by surface-enhanced Raman scattering (SERS) substrates based on lithographically-defined two-dimensional rectangular array of nanopillars. The type of nanopillars is known as the tapered pillars. For the tapered pillars, SERS enhancement arises from the nanofocusing effect due to the sharp tip on top. SERS experiments were carried out on these substrates using various concentrations of toluene vapor. The results show that SERS signal from a toluene vapor concentration of ppm level can be achieved, and the toluene vapor can be detected within minutes of exposing the SERS substrate to the vapor. A simple adsorption model is developed which gives results matching the experimental data. The results also show promising potential for the use of these substrates in environmental monitoring of gases and vapors.
Date: March 22, 2012
Creator: Chang, A. S.; Maiti, A.; Ileri, N.; Bora, M.; Larson, C. C.; Britten, J. A. et al.
System: The UNT Digital Library
Estimating the Bias of Local Polynomial Approximations Using the Peano Kernel (open access)

Estimating the Bias of Local Polynomial Approximations Using the Peano Kernel

These presentation visuals define local polynomial approximations, give formulas for bias and random components of the error, and express bias error in terms of the Peano kernel. They further derive constants that give figures of merit, and show the figures of merit for 3 common weighting functions. The Peano kernel theorem yields estimates for the bias error for local-polynomial-approximation smoothing that are superior in several ways to the error estimates in the current literature.
Date: March 22, 2012
Creator: Blair, J., and Machorro, E.
System: The UNT Digital Library
Micro-Analysis of Actinide Minerals for Nuclear Forensics and Treaty Verification (open access)

Micro-Analysis of Actinide Minerals for Nuclear Forensics and Treaty Verification

Micro-Raman spectroscopy has been demonstrated to be a viable tool for nondestructive determination of the crystal phase of relevant minerals. Collecting spectra on particles down to 5 microns in size was completed. Some minerals studied were weak scatterers and were better studied with the other techniques. A decent graphical software package should easily be able to compare collected spectra to a spectral library as well as subtract out matrix vibration peaks. Due to the success and unequivocal determination of the most common mineral false positive (zircon), it is clear that Raman has a future for complementary, rapid determination of unknown particulate samples containing actinides.
Date: March 22, 2012
Creator: M. Morey, M. Manard, R. Russo, G. Havrilla
System: The UNT Digital Library