Analytical Model of Cold-formed Steel Framed Shear Wall with Steel Sheet and Wood-based Sheathing (open access)

Analytical Model of Cold-formed Steel Framed Shear Wall with Steel Sheet and Wood-based Sheathing

The cold-formed steel framed shear walls with steel sheets and wood-based sheathing are both code approved lateral force resisting system in light-framed construction. In the United States, the current design approach for cold-formed steel shear walls is capacity-based and developed from full-scale tests. The available design provisions provide nominal shear strength for only limited wall configurations. This research focused on the development of analytical models of cold-formed steel framed shear walls with steel sheet and wood-based sheathing to predict the nominal shear strength of the walls at their ultimate capacity level. Effective strip model was developed to predict the nominal shear strength of cold-formed steel framed steel sheet shear walls. The proposed design approach is based on a tension field action of the sheathing, shear capacity of sheathing-to-framing fastener connections, fastener spacing, wall aspect ratio, and material properties. A total of 142 full scale test data was used to verify the proposed design method and the supporting design equations. The proposed design approach shows consistent agreement with the test results and the AISI published nominal strength values. Simplified nominal strength model was developed to predict the nominal shear strength of cold-formed steel framed wood-based panel shear walls. The nominal shear …
Date: May 2013
Creator: Yanagi, Noritsugu
System: The UNT Digital Library
Cold-formed Steel Framed Shear Wall Sheathed with Corrugated Sheet Steel (open access)

Cold-formed Steel Framed Shear Wall Sheathed with Corrugated Sheet Steel

Incombustibility is one important advantage of the sheet steel sheathed shear wall over wood panel sheathed shear wall. Compared to shear wall sheathed with plywood and OSB panel, shear wall sheathed with flat sheet steel behaved lower shear strength. Although shear wall sheathed with corrugated sheet steel exhibited high nominal strength and high stiffness, the shear wall usually behaved lower ductility resulting from brittle failure at the connection between the sheathing to frames. This research is aimed at developing modifications on the corrugated sheathing to improve the ductility of the shear wall as well as derive practical response modification factor by establishing correct relationship between ductility factor ? and response modification factor R. Totally 21 monotonic and cyclic full-scale shear wall tests were conducted during the winter break in 2012 by the author in NUCONSTEEL Materials Testing Laboratory in the University of North Texas. The research investigated nineteen 8 ft. × 4 ft. shear walls with 68 mil frames and 27 mil corrugation sheet steel in 11 configurations and two more shear walls sheathed with 6/17-in.OSB and 15/32-in. plywood respectively for comparison. The shear walls, which were in some special cutting arrangement patterns, performed better under lateral load conditions according …
Date: May 2013
Creator: Yu, Guowang
System: The UNT Digital Library
Direct Strength Method for Web Crippling of Cold-formed Steel C-sections (open access)

Direct Strength Method for Web Crippling of Cold-formed Steel C-sections

Web crippling is a form of localized buckling that occurs at points of transverse concentrated loading or supports of thin-walled structural members. The theoretical computation of web crippling strength is quite complex as it involves a large number of factors such as initial imperfections, local yielding at load application and instability of web. The existing design provision in North American specification for cold-formed steel C-sections (AISI S100, 2007) to calculate the web-crippling strength is based on the experimental investigation. The objective of this research is to extend the direct strength method to the web crippling strength of cold-formed steel C-sections. ABAQUS is used as a main tool to apply finite element analysis and is used to do the elastic buckling analysis. The work was carried out on C-sections under interior two flange (ITF) loading, end two flange (ETF) loading cases. Total of 128 (58 ITF, 70 ETF) sections were analyzed. Sections with various heights (3.5 in.to 6 in.) and various lengths (21 in. to 36 in.) were considered. Data is collected from the tests conducted in laboratory and the data from the previous researches is used, to extend the direct strength method to cold formed steel sections. Proposing a new …
Date: May 2013
Creator: Seelam, Praveen Kumar Reddy
System: The UNT Digital Library
Corrosion Protection of Low Carbon Steel By Cation Substituted Magnetite (open access)

Corrosion Protection of Low Carbon Steel By Cation Substituted Magnetite

Surfaces of low carbon steel sheet were modified by exposure to highly caustic aqueous solutions containing either chromium or aluminum cations. Corrosion resistances of such surfaces were compared with that of steel surfaces exposed to plain caustic aqueous solution. In all cases a highly uniform, black coating having a spinel structure similar to magnetite (Fe3O4) was obtained. The coated steel surfaces were characterized using X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and Fourier transform infrared spectrophotometry (FTIR). Polarization resistances (Rp) of modified steel surfaces were measured and compared with that of bare steel surfaces. Results indicate that chromium (Fe2+ Fe3+x Cr3+1-x) or aluminum (Fe2+ Fe3+x Al3+1-x) substituted spinel phases formed on steel surfaces showed higher Rp values compared to only magnetite (Fe2+ 2Fe3+O4) phase formed in the absence of either chromium or aluminum cations. Average Rp values for steel surfaces with chromium containing spinel phase were much higher (21.8 k?) as compared to 1.7 k? for bare steel surfaces. Steel surfaces with aluminum containing spinel phase and steels with plain magnetite coated samples showed average Rp values of 3.3 k? and 2.5 k? respectively. XPS and EDS analysis confirmed presence of cations of chromium and …
Date: May 2013
Creator: Phadnis, Ameya
System: The UNT Digital Library
Effects of Processing Techniques on Mechanical Properties of Selected Polymers (open access)

Effects of Processing Techniques on Mechanical Properties of Selected Polymers

The mechanical properties of a polymer represent the critical characteristics to be considered when determining the applications for it. The same polymer processed with different methods can exhibit different mechanical properties. The purpose of this study is to investigate the difference in mechanical properties of the selected polymers caused by different processing techniques and conditions. Three polymers were studied, including low density polyethylene (LDPE), polypropylene (PP), and NEXPRENE® 1287A. Samples were processed with injection molding and compression molding under different processing condition. Tensile and DMA tests were performed on these samples. The acquired data of strain at break from the tensile tests and storage modulus from the DMA were utilized to calculate brittleness. Calculated brittleness values were used to perform analysis of variance (ANOVA) to investigate the statistical significance of the processing technique and condition. It was found that different processing techniques affect the brittleness significantly. The processing technique is the major factor affecting brittleness of PP and NEXPRENE, and the processing temperature is the major factor affecting brittleness of LDPE.
Date: May 2013
Creator: Dong, Yao
System: The UNT Digital Library
Innovative Cold-Formed Steel Shear Walls with Corrugated Steel Sheathing (open access)

Innovative Cold-Formed Steel Shear Walls with Corrugated Steel Sheathing

This thesis presents two major sections with the objective of introducing a new cold-formed steel (CFS) shear wall system with corrugated steel sheathings. The work shown herein includes the development of an optimal shear wall system as well as an optimal slit configuration for the CFS corrugated sheathings which result in a CFS shear wall with high ductility, high strength, high stiffness and overall high performance. The conclusion is based on the results of 36 full-scale shear wall tests performed in the structural laboratory of the University of North Texas. A variety of shear walls were the subject of this research to make further discussions and conclusions based on different sheathing materials, slit configurations, wall configurations, sheathing connection methods, wall dimensions, shear wall member thicknesses, and etc. The walls were subject to cyclic (CUREE protocol) lateral loading to study their deformations and structural performances. The optimal sit configuration for CFS shear walls with corrugated steel sheathings was found to be 12×2 in. vertical slits in 6 rows. The failure mode observed in this shear wall system was the connection failure between the sheathing and the framing members. Also, most of the shear walls tested displayed local buckling of the chord …
Date: May 2016
Creator: Mahdavian, Mahsa
System: The UNT Digital Library
Accelerated Corrosion Test with Operation Simulation of All-Aluminum Microchannel Heat Exchangers (open access)

Accelerated Corrosion Test with Operation Simulation of All-Aluminum Microchannel Heat Exchangers

The HVAC&R industry is looking to transition from copper-aluminum heat exchangers to all-aluminum microchannel technology. The want for the transition stemmed from seeing the performance improvement of all-aluminum microchannel radiators in the automotive industry. Applications differ between the two industries; therefore, applying this technology for HVAC&R use must be validated. Research towards operating modes of an all-aluminum heat exchanger in a defined corrosive environment will provide the industry with a better understanding of heat exchanger design and heat exchanger material selection. The worth in this is preventing overdesign and producing more efficient heat exchangers. Furthermore, ASHRAE members and the corrosion community will find value in a defined corrosion system and corrosion test procedure. The information gained through past research has progressed assessment of material performance; however, the methods improperly simulate and expedite natural weathering. The most common method being used is the ASTM (American Society of Testing Materials) Sea Water Acetic Acid Test. The research discussed in this paper was focused on improving a standard corrosion system by implementing system modifications to simulate heat exchanger operation while performing a modified wet-dry cyclic test (e.g. ASTM G85 Annex 5). The goal is to produce results that are more representative of natural …
Date: May 2016
Creator: Vaughan, Haydn
System: The UNT Digital Library
Effects of Rebar Temperature and Water to Cement Ratio on Rebar-Concrete Bond Strength of Concrete Containing Fly Ash (open access)

Effects of Rebar Temperature and Water to Cement Ratio on Rebar-Concrete Bond Strength of Concrete Containing Fly Ash

This research presents the results on an experimental investigation to identify the effects of rebar temperature, fly ash and water to cement ratio on concrete porosity in continuously reinforced concrete pavements (CRCP). Samples were cast and analyzed using pullout tests. Water to cement ratio (w/c) and rebar temperature had a significant influence on the rebar-concrete bond strength. The 28-day shear strength measurements showed an increase in rebar-concrete bond strength as the water to cement ratio (w/c) was reduced from 0.50 to 0.40 for both fly ash containing and non fly ash control samples. There was a reduction in the peak pullout load as the rebar surface temperature increased from 77o F to 150o F for the cast samples. A heated rebar experiment was performed simulating a rebar exposed to hot summer days and the rebar cooling curves were plotted for the rebar temperatures of 180o F - 120o F. Fourier transform infrared spectroscopy was performed to show the moisture content of cement samples at the rebar-concrete interface. Mercury intrusion porosimetry test results on one batch of samples were used for pore size distribution analysis. An in-depth analysis of the morphological characteristics of the rebar-concrete interface and the observation of pores …
Date: May 2010
Creator: Pati, Ardeep Ranjan
System: The UNT Digital Library
The Design and Development of Lightweight Composite Wall, Roof, and Floor Panels for Rigid Wall Shelter (open access)

The Design and Development of Lightweight Composite Wall, Roof, and Floor Panels for Rigid Wall Shelter

This thesis presents a research effort aimed at developing a stronger, lighter, and more economic shelter using rigid wall panels. Reported herein is insulation research, wall and roof panel design and testing, floor section modeling and strength calculations, and cost and weight calculations. Beginning stages focus on developing solid wall and roof panels using cold-formed steel corrugated sheathing and members, as well as polyurethane spray foam for insulation. This research includes calculating uniform load density, to determine the overall strength of the panel. The next stage focuses on the flexural strength of the wall and roof panels, as well as finalizing the floor design for the shelter. This includes determining maximum flexural strength required to meet the standards set by the project goal. Direct strength method determined the correct thickness of members to use based on the dimension selected for the design. All Phases incorporated different connection methods, with varied stud spacing, to determine the safest design for the new shelters. Previous research has shown that cold-formed steel corrugated sheathing performs better than thicker flat sheathing of various construction materials, with screw and spot weld connections. Full scale shear wall tests on this type of shear wall system have been …
Date: May 2018
Creator: Artman, Jeremy J
System: The UNT Digital Library
Investigation of Spray Cooling Schemes for Dynamic Thermal Management (open access)

Investigation of Spray Cooling Schemes for Dynamic Thermal Management

This study aims to investigate variable flow and intermittent flow spray cooling characteristics for efficiency improvement in active two-phase thermal management systems. Variable flow spray cooling scheme requires control of pump input voltage (or speed), while intermittent flow spray cooling scheme requires control of solenoid valve duty cycle and frequency. Several testing scenarios representing dynamic heat load conditions are implemented to characterize the overall performance of variable flow and intermittent flow spray cooling cases in comparison with the reference, steady flow spray cooling case with constant flowrate, continuous spray cooling. Tests are conducted on a small-scale, closed loop spray cooling system featuring a pressure atomized spray nozzle. HFE-7100 dielectric liquid is selected as the working fluid. Two types of test samples are prepared on 10 mm x 10 mm x 2 mm copper substrates with matching size thick film resistors attached onto the opposite side, to generate heat and simulate high heat flux electronic devices. The test samples include: (i) plain, smooth surface, and (ii) microporous surface featuring 100 μm thick copper-based coating prepared by dual stage electroplating technique. Experimental conditions involve HFE-7100 at atmospheric pressure and 30°C and ~10°C subcooling. Steady flow spray cooling tests are conducted at flow …
Date: May 2017
Creator: Yata, Vishnu Vardhan Reddy
System: The UNT Digital Library
Design, Modeling, and Experiment of a Piezoelectric Pressure Sensor based on a Thickness-Shear Mode Crystal Resonator (open access)

Design, Modeling, and Experiment of a Piezoelectric Pressure Sensor based on a Thickness-Shear Mode Crystal Resonator

This thesis presents the design, modeling, and experiment of a novel pressure sensor using a dual-mode AT-cut quartz crystal resonator with beat frequency analysis based temperature compensation technique. The proposed sensor can measure pressure and temperature simultaneously by a single AT-cut quartz resonator. Apart from AT-cut quartz crystal, a newly developed Langasite (LGS) crystal resonator is also considered in the proposed pressure sensor design, since LGS can operate in a higher temperature environment than AT-cut quartz crystal. The pressure sensor is designed using CAD (computer aided design) software and CAE software - COMSOL Multiphysics. Finite element analysis (FEA) of the pressure sensor is performed to analyze the stress- strain of the sensor's mechanical structure. A 3D printing prototype of the sensor is fabricated and the proposed sensing principle is verified using a force-frequency analysis apparatus. Next to the 3D printing model verification, the pressure sensor with stainless steel housing has been fabricated with inbuilt crystal oscillator circuit. The oscillator circuit is used to excite the piezo crystal resonator at its fundamental vibrational mode and give the frequency as an output signal. Based on the FEA and experimental results, it has been concluded that the maximum pressure that the sensor can …
Date: May 2017
Creator: Pham, Thanh Tuong
System: The UNT Digital Library
Ota-quadrotor: An Object-tracking Autonomous Quadrotor for Real-time Detection and Recognition (open access)

Ota-quadrotor: An Object-tracking Autonomous Quadrotor for Real-time Detection and Recognition

The field of robotics and mechatronics is advancing at an ever-increasing rate and we are starting to see robots making the transition from the factories to the workplace and homes as cost is reduced and they become more useful. In recent years quadrotors have become a popular unmanned air vehicle (UAV) platform. These UAVs or micro air vehicles (MAV) are being used for many new and exciting applications such as aerial monitoring of wildlife, disaster sites, riots and protests. They are also being used in the film industry, as they are significantly cheaper means of getting aerial footage. While quadrotors are not extremely expensive a good system can cost in the range of $3000 - $8000 and thus too costly as a research platform for many. There are a number of cheaper open source platforms. The ArduCopter is under constant development, has the largest community and is inexpensive making it an ideal platform to work with. The goal of this thesis was to implement video processing on a ground control station allowing for the ArduCopter to track moving objects. This was achieved by using the OpenCV video-processing library to implement object tracking and the MAVLink communication protocol, available on the …
Date: May 2012
Creator: Coelho, Gavin
System: The UNT Digital Library
Mechanical Characterization of A2 and D2 Tool Steels By Nanoindentation (open access)

Mechanical Characterization of A2 and D2 Tool Steels By Nanoindentation

Nanoindentation technique was used to investigate the surface properties of A2 and D2 tool steel subjected to different heat treatments. the mechanical characteristics of these two easily available tool steels were studied based on microstructural images obtained from SEM, the grain growth after heat treatment using X-ray diffraction method and nanoindentation technique. the investigation showed that a single nanoindentation result can explain how heat treatment influences reliability and failure in A2 and D2 tool steels. in this work, the causes and effects of these variations were studied to explain how they influence reliability and failure in A2 and D2 tool steel. Finally, a cube-corner indenter tip was used to determine the fracture toughness of silicon wafer. the emphasis of this research is on how nanoindentation technique is more extensive in material characterization.
Date: May 2012
Creator: Okafor, Uzochukwu Chimezie
System: The UNT Digital Library
Bearing Strength of Cold Formed Steel Bolted Connections in Trusses (open access)

Bearing Strength of Cold Formed Steel Bolted Connections in Trusses

The existing design provision in North American Specification for Cold- Formed Steel Structural Member (AISI S100) for the bearing strength of bolted connections were developed from tests on bolted connected sheets which were restrained by bolt nut and head with or without washers. However, in the cold-formed assemblies, particularly in trusses, the single bolt goes through both sides of the connected sections, making the connected sheets on each side unrestrained. the warping of the unrestrained sheet may reduce the bearing strength of the bolted connection. This research investigates the behavior and strength of bearing failure in bolted connections in cold-formed steel trusses. Tensile tests were conducted on trusses connections with various material thicknesses. It was found that the AISI S100 works well for thick connections but provides unconservative predictions for thin materials. Based on the experimental results, a modified bearing strength method is proposed for calculating the bearing strength of bolted truss connections. the proposed method can be used for any cold-formed steel connections with unrestrained sheet.
Date: May 2012
Creator: Panyanouvong, Mark
System: The UNT Digital Library
Nominal Shear Strength of Cold-formed Steel Shear Walls Using Osb Sheathing (open access)

Nominal Shear Strength of Cold-formed Steel Shear Walls Using Osb Sheathing

In the cold-formed steel construction, the oriented strand board is a common material for shear wall sheathing. an OSB is made by using wood chips as raw materials that undergo high temperature pressing to create a multi-larger structure material. Due to the OSB having a high strength in shear, it is an important material used in the construction field. the thesis is trying to verify published nominal shear strength in AISI-213-07 in the first part. This objective has two parts: the first part is to verify nominal shear strength (Rn) for wind and other in-plane loads for shear wall. the second part is to verify nominal shear strength (Rn) for seismic and other in-plane loads for shear wall. Secondly, the thesis verifies the design deflection equation for nominal shear strength of CFS shear walls with OSB sheathing. the test specimens were divided into eight groups which trying to verify the design deflection equation that was published in AISI-213-07 standard.
Date: May 2012
Creator: Li, Chao
System: The UNT Digital Library
Recommended Modified zone Method Correction Factor for Determining R-values of Cold-Formed Steel Wall Assemblies (open access)

Recommended Modified zone Method Correction Factor for Determining R-values of Cold-Formed Steel Wall Assemblies

Currently, ASHRAE has determined the zone method and modified zone method are appropriate calculation methods for materials with a high difference in conductivity, such as cold-formed steel (CFS) walls. Because there is currently no standard U-Factor calculation method for CFS walls, designers and code officials alike tend to resort to the zone method. However, the zone method is restricted to larger span assemblies because the zone factor coefficient is 2.0. This tends to overestimate the amount of surface area influenced by CFS. The modified zone method is restricted to C-shaped stud, clear wall assemblies with framing factors between 9 and 15%. The objective of the research is to narrow the gap of knowledge by re-examining the modified zone method in order to more accurately determine R-Values and U-Factors for CFS wall assemblies with whole wall framing factor percentages of 22% and above.
Date: May 2011
Creator: Black, John
System: The UNT Digital Library
A Study on the System Reliability of Cold-Formed Steel Roof Trusses (open access)

A Study on the System Reliability of Cold-Formed Steel Roof Trusses

This thesis presents a research project aimed at advancing the treatment of cold-formed steel (CFS) structural reliability in roof trusses. Structural design today relies almost exclusively on component-level design, so structural safety is assured by limiting the probability of failure of individual components. Reliability of the entire system is typically not assessed, so in a worst-case scenario the system reliability may be less than the component reliability, or in a best-case scenario the system reliability may be much greater than the component reliability. A roof truss itself, is a subsystem with several possible failure modes that are being studied in this test program. These trusses are constructed of CFS members that nest with one another at the truss nodes and are connected by drilling fasteners through the mated surfaces, as well as having steel sheathing fastened to the top chords for lateral bracing. Presented in this paper is a series of full-scale static tests on single cold-formed steel roof trusses with a unique experimental setup. The test specimens were carefully monitored to address multiple failure modes: buckling of the top chord, buckling of the truss webs, and any connection failures. This research includes the experimental results, the computed system reliability …
Date: May 2017
Creator: Johnson, Adam M.
System: The UNT Digital Library
Design of a Machine Condition Monitoring System with Bluetooth Low Energy (open access)

Design of a Machine Condition Monitoring System with Bluetooth Low Energy

This thesis discusses the design considerations for a machine conditioning sensor utilizing Bluetooth low energy (BLE).
Date: May 2017
Creator: Tompkins, Nicholas
System: The UNT Digital Library

Cold-Formed Steel Member Connections Using BAC Screw Fasteners

Access: Use of this item is restricted to the UNT Community
In this project, the main research objective is intend to seek criteria for evaluating the capacity of BAC screw fasteners with mixed configuration of waterproof seal washer, sealer tape and different pre-drill holes to determine shear and tension strength values for the screws used in cold-formed steel connections. The thesis presents the design methods and test program conducted to investigate the behavior and strength of the screw connections in shear and tension test. Test results were compared with AISI design provisions to determine if new design equations will be developed for those screws used in BAC cooling tower applications. LRFD resistance factors and ASD safety factors were investigated to the proposed design equations.
Date: May 2019
Creator: Li, Xun
System: The UNT Digital Library
Topology and Lattice-Based Structural Design Optimization for Additively Manufactured Medical Implants (open access)

Topology and Lattice-Based Structural Design Optimization for Additively Manufactured Medical Implants

Topology-based optimization techniques and lattice structures are powerful ways to accomplish lightweight components with enhanced mechanical performance. Recent developments in additive manufacturing (AM) have led the way to extraordinary opportunities in realizing complex designs that are derived from topology and lattice-based structural optimization. The main aim of this work is to give a contribution, in the integration between structural optimization techniques and AM, by proposing a setup of a proper methodology for rapid development of optimized medical implants addressing oseeointegration and minimization of stress shielding related problems. The validity of the proposed methodology for a proof of concept was demonstrated in two real-world case studies: a tibia intramedullary implant and a shoulder hemi prosthetics for two bone cancer patients. The optimization was achieved using topology optimization and replacement of solid volumes by lattice structures. Samples of three lattice unit cell configurations were designed, fabricated, mechanically tested, and compared to select the most proper configuration for the shoulder hemi prosthesis. Weight reductions of 30% and 15% were achieved from the optimization of the initial design of the tibia intramedullary implant and the shoulder hemiprosthesis respectively compared to initial designs. Prototypes were fabricated using selective laser melting (SLM) and direct light processing …
Date: May 2019
Creator: Peto, Marinela
System: The UNT Digital Library