Effects of Processing Techniques on Mechanical Properties of Selected Polymers (open access)

Effects of Processing Techniques on Mechanical Properties of Selected Polymers

The mechanical properties of a polymer represent the critical characteristics to be considered when determining the applications for it. The same polymer processed with different methods can exhibit different mechanical properties. The purpose of this study is to investigate the difference in mechanical properties of the selected polymers caused by different processing techniques and conditions. Three polymers were studied, including low density polyethylene (LDPE), polypropylene (PP), and NEXPRENE® 1287A. Samples were processed with injection molding and compression molding under different processing condition. Tensile and DMA tests were performed on these samples. The acquired data of strain at break from the tensile tests and storage modulus from the DMA were utilized to calculate brittleness. Calculated brittleness values were used to perform analysis of variance (ANOVA) to investigate the statistical significance of the processing technique and condition. It was found that different processing techniques affect the brittleness significantly. The processing technique is the major factor affecting brittleness of PP and NEXPRENE, and the processing temperature is the major factor affecting brittleness of LDPE.
Date: May 2013
Creator: Dong, Yao
System: The UNT Digital Library
Effects of Rebar Temperature and Water to Cement Ratio on Rebar-Concrete Bond Strength of Concrete Containing Fly Ash (open access)

Effects of Rebar Temperature and Water to Cement Ratio on Rebar-Concrete Bond Strength of Concrete Containing Fly Ash

This research presents the results on an experimental investigation to identify the effects of rebar temperature, fly ash and water to cement ratio on concrete porosity in continuously reinforced concrete pavements (CRCP). Samples were cast and analyzed using pullout tests. Water to cement ratio (w/c) and rebar temperature had a significant influence on the rebar-concrete bond strength. The 28-day shear strength measurements showed an increase in rebar-concrete bond strength as the water to cement ratio (w/c) was reduced from 0.50 to 0.40 for both fly ash containing and non fly ash control samples. There was a reduction in the peak pullout load as the rebar surface temperature increased from 77o F to 150o F for the cast samples. A heated rebar experiment was performed simulating a rebar exposed to hot summer days and the rebar cooling curves were plotted for the rebar temperatures of 180o F - 120o F. Fourier transform infrared spectroscopy was performed to show the moisture content of cement samples at the rebar-concrete interface. Mercury intrusion porosimetry test results on one batch of samples were used for pore size distribution analysis. An in-depth analysis of the morphological characteristics of the rebar-concrete interface and the observation of pores …
Date: May 2010
Creator: Pati, Ardeep Ranjan
System: The UNT Digital Library
Application of FTIR for Quantification of Alkali in Cement (open access)

Application of FTIR for Quantification of Alkali in Cement

Alkali-silica reaction (ASR) in cement is a major contributor to failure of cement structures around the world, causing increased repair costs and possible rebuild expenses. Alkali levels are indicative of the potential for ASR and are therefore measured and quantified. A linear correlation relating cement alkali concentration measured by X-ray fluorescence spectroscopy (XRF) and peak ratio measured by Fourier transform infrared spectroscopy (FTIR) is developed. Regression analysis of plots correlating alkali content measured by FTIR absorption band (750 cm-1/923 cm-1) ratio versus equivalent alkali (Na2O)e (%Na2O + 0.658 % K2O) quantified by XRF show linear correlation coefficient, R2, of 0.97. Results of this investigation are discussed in terms of microstructural disorder coefficient Cd which is a reactivity criterion for ASR-susceptible aggregates proposed by Bachiorrini [31]. XRF is a popular technique for alkali quantification but FTIR is faster, safer, and less expensive technique compared to XRF. Portable instrumentation is available for both techniques but FTIR systems are less expensive.
Date: May 2011
Creator: Springfield, Tyler
System: The UNT Digital Library
Nominal Shear Strength of Cold-formed Steel Shear Walls Using Osb Sheathing (open access)

Nominal Shear Strength of Cold-formed Steel Shear Walls Using Osb Sheathing

In the cold-formed steel construction, the oriented strand board is a common material for shear wall sheathing. an OSB is made by using wood chips as raw materials that undergo high temperature pressing to create a multi-larger structure material. Due to the OSB having a high strength in shear, it is an important material used in the construction field. the thesis is trying to verify published nominal shear strength in AISI-213-07 in the first part. This objective has two parts: the first part is to verify nominal shear strength (Rn) for wind and other in-plane loads for shear wall. the second part is to verify nominal shear strength (Rn) for seismic and other in-plane loads for shear wall. Secondly, the thesis verifies the design deflection equation for nominal shear strength of CFS shear walls with OSB sheathing. the test specimens were divided into eight groups which trying to verify the design deflection equation that was published in AISI-213-07 standard.
Date: May 2012
Creator: Li, Chao
System: The UNT Digital Library
Recommended Modified zone Method Correction Factor for Determining R-values of Cold-Formed Steel Wall Assemblies (open access)

Recommended Modified zone Method Correction Factor for Determining R-values of Cold-Formed Steel Wall Assemblies

Currently, ASHRAE has determined the zone method and modified zone method are appropriate calculation methods for materials with a high difference in conductivity, such as cold-formed steel (CFS) walls. Because there is currently no standard U-Factor calculation method for CFS walls, designers and code officials alike tend to resort to the zone method. However, the zone method is restricted to larger span assemblies because the zone factor coefficient is 2.0. This tends to overestimate the amount of surface area influenced by CFS. The modified zone method is restricted to C-shaped stud, clear wall assemblies with framing factors between 9 and 15%. The objective of the research is to narrow the gap of knowledge by re-examining the modified zone method in order to more accurately determine R-Values and U-Factors for CFS wall assemblies with whole wall framing factor percentages of 22% and above.
Date: May 2011
Creator: Black, John
System: The UNT Digital Library