Exploitation of Dynamic Communication Patterns through Static Analysis (open access)

Exploitation of Dynamic Communication Patterns through Static Analysis

None
Date: June 27, 2010
Creator: Preissl, R; de Supinski, B; Schulz, M; Quinlan, D; Kranzlmueller, D & Panas, T
Object Type: Article
System: The UNT Digital Library

HVAC Loads in High-Performance Homes

This presentation was delivered at the ASHRAE 2010 Annual Summer Conference on June 27, 2010, and addresses humidity and AC loads in energy efficient houses.
Date: June 27, 2010
Creator: Christensen, D.; Fang, X. & Winkler, J.
Object Type: Presentation
System: The UNT Digital Library
RACORO Long-Term, Systematic Aircraft Observations of Boundary Layer Clouds (open access)

RACORO Long-Term, Systematic Aircraft Observations of Boundary Layer Clouds

Our knowledge of boundary layer cloud processes is insufficient to resolve pressing scientific problems. Boundary layer clouds often have liquid-water paths (LWPs) less than 100 gm{sup 2}, which are defined here as being 'thin' Clouds with Low Optical Water Depths (CLOWD). This type of cloud is common globally, and the Earth's radiative energy balance is particularly sensitive to small changes in their optical properties. However, it is difficult to retrieve accurately their cloud properties via remote sensing because they are tenuous and often occur in partly cloudy skies. This interferes with our ability to obtain the routine, long-term statistics needed to improve their representation in climate models. To address this problem, in-situ data are needed to investigate cloud processes and to evaluate and refine existing retrieval algorithms. Coordinated by the ARM Aerial Facility (AAF), the Routine AAF CLOWD Optical Radiative Observations (RACORO) field campaign conducted long-term, systematic flights in boundary layer, liquid-water clouds over the ARM Southern Great Plains (SGP) site between 22 January and 30 June 2009. This was the first time that a long-term aircraft campaign was undertaken for systematic in-situ sampling of cloud properties. Using the CIRPAS Twin Otter aircraft equipped with a comprehensive set of instruments …
Date: June 27, 2010
Creator: Vogelmann, A. M.; McFarquhar, G.; Ogren, J.; Turner, D. D.; Comstock, J. M.; Feingold, G. et al.
Object Type: Article
System: The UNT Digital Library
Tracking tropical cloud systems for the diagnosis of simulations by the weather research and forecasting (WRF) model (open access)

Tracking tropical cloud systems for the diagnosis of simulations by the weather research and forecasting (WRF) model

To aid in improving model parameterizations of clouds and convection, we examine the capability of models, using explicit convection, to simulate the life cycle of tropical cloud systems in the tropical warm pool. The cloud life cycle is determined using a satellite cloud tracking algorithm (Boer and Ramanathan, J. Geophys. Res., 1997), and the statistics are compared to those of simulations using the Weather Research and Forecasting (WRF) Model. Using New York Blue, a Blue Gene/L supercomputer that is co-operated by Brookhaven and Stony Brook, simulations are run at a resolution comparable to the observations. Initial results suggest that the organization of the mesoscale convective systems is particularly sensitive to the cloud microphysics parameterization used.
Date: June 27, 2010
Creator: Vogelmann, A.M.; Lin, W.; Cialella, A.; Luke, E. P.; Jensen, M. P.; Zhang, M. H. et al.
Object Type: Article
System: The UNT Digital Library
Use of High Magnetic Field to Control Microstructural Evolution  in Metallic and Magnetic Materials (open access)

Use of High Magnetic Field to Control Microstructural Evolution in Metallic and Magnetic Materials

The Amendment 1, referred to as Phase 2, to the original CRADA NFE-06-00414 added tasks 3 through 7 to the original statement of work that had two main tasks that were successfully accomplished in Phase 1 of this project. In this Phase 2 CRADA extension, extensive research and development activities were conducted using high magnetic field processing effects for the purpose of manipulating microstructure in the SAE 5160 steel to refine grain size isothermally and to develop nanocrystalline spacing pearlite during continuous cooling, and to enhance the formability/forgability of the non-ferrous precipitation hardening magnesium alloy AZ90 by applying a high magnetic field during deformation processing to investigate potential magnetoplasticity in this material. Significant experimental issues (especially non-isothermal conditions evolving upon insertion of an isothermal sample in the high magnetic field) were encountered in the isothermal phase transformation reversal experiments (Task 4) that later were determined to be due to various condensed matter physics phenomenon such as the magnetocaloric (MCE) effect that occurs in the vicinity of a materials Curie temperature. Similarly the experimental deformation rig had components for monitoring deformation/strain (Task 3) that were susceptible to the high magnetic field of the ORNL Thermomagnetic Processing facility 9-T superconducting magnet that …
Date: June 27, 2010
Creator: Ludtka, G. M.; Mackiewicz- Ludtka, G.; Wilgen, J. B. & Kisner, R. A.
Object Type: Report
System: The UNT Digital Library
2010 Wind Technologies Market Report (open access)

2010 Wind Technologies Market Report

The U.S. wind power industry experienced a trying year in 2010, with a significant reduction in new builds compared to both 2008 and 2009. The delayed impact of the global financial crisis, relatively low natural gas and wholesale electricity prices, and slumping overall demand for energy countered the ongoing availability of existing federal and state incentives for wind energy deployment. The fact that these same drivers did not impact capacity additions in 2009 can be explained, in part, by the 'inertia' in capital-intensive infrastructure investments: 2009 capacity additions were largely determined by decisions made prior to the economy-wide financial crisis that was at its peak in late 2008 and early 2009, whereas decisions on 2010 capacity additions were often made at the height of the financial crisis. Cumulative wind power capacity still grew by a healthy 15% in 2010, however, and most expectations are for moderately higher wind power capacity additions in 2011 than witnessed in 2010, though those additions are also expected to remain below the 2009 high.
Date: June 27, 2011
Creator: Wiser, Ryan; Bolinger, Mark; Barbose, Galen; Darghouth, Naïm; Hoen, Ben; Mills, Andrew et al.
Object Type: Report
System: The UNT Digital Library
Advances in Process Intensification through Multifunctional Reactor Engineering (open access)

Advances in Process Intensification through Multifunctional Reactor Engineering

This project was designed to advance the art of process intensification leading to a new generation of multifunctional chemical reactors utilizing pulse flow. Experimental testing was performed in order to fully characterize the hydrodynamic operating regimes associated with pulse flow for implementation in commercial applications. Sandia National Laboratories (SNL) operated a pilot-scale multifunctional reactor experiment for operation with and investigation of pulse flow operation. Validation-quality data sets of the fluid dynamics, heat and mass transfer, and chemical kinetics were acquired and shared with Chemical Research and Licensing (CR&L). Experiments in a two-phase air-water system examined the effects of bead diameter in the packing, and viscosity. Pressure signals were used to detect pulsing. Three-phase experiments used immiscible organic and aqueous liquids, and air or nitrogen as the gas phase. Hydrodynamic studies of flow regimes and holdup were performed for different types of packing, and mass transfer measurements were performed for a woven packing. These studies substantiated the improvements in mass transfer anticipated for pulse flow in multifunctional reactors for the acid-catalyzed C4 paraffin/olefin alkylation process. CR&L developed packings for this alkylation process, utilizing their alkylation process pilot facilities in Pasadena, TX. These packings were evaluated in the pilot-scale multifunctional reactor experiments …
Date: June 27, 2011
Creator: Timothy O’Hern, Lindsey Evans, Jim Miller, Marcia Cooper, John Torczynski, Donovan Pena, and Walt Gill, SNL, Will Groten, Arvids Judzis, Richard Foley, Larry Smith, and Will Cross, CR&L / CDTECH & T. Vogt, Lummus Technology / CDTECH.
Object Type: Report
System: The UNT Digital Library
Annual Report of Monitoring at Morrill, Kansas, in 2010. (open access)

Annual Report of Monitoring at Morrill, Kansas, in 2010.

Carbon tetrachloride contamination in groundwater at Morrill, Kansas, was initially identified in 1985 during statewide testing of public water supply wells for volatile organic compounds (VOCs). High levels of nitrate were also present in the wells. The city of Morrill is located in Brown County in the northeastern corner of the state, about 7 mi east of Sabetha. The population of Morrill as of the 2000 census was approximately 277. All residents of Morrill now obtain their drinking water from the Sabetha municipal water system via a pipeline constructed in 1991. Starting in 1922, eight different public wells formerly served the Morrill municipal system at some time. Because of poor water quality, including high nitrate levels attributed to numerous animal feeding operations in the vicinity and application of fertilizer on agricultural lands, use of the local groundwater from any public well for municipal supply purposes was terminated in 1991 in favor of obtaining water from the Sabetha municipal water system. Investigations of the carbon tetrachloride and nitrate contamination by the Kansas Department of Health and Environment (KDHE) in 1989, 1994, and 1996 (KDHE 1989; GeoCore 1994a-e, 1996) identified a localized plume of carbon tetrachloride in groundwater extending downgradient from a …
Date: June 27, 2011
Creator: LaFreniere, L. M.
Object Type: Report
System: The UNT Digital Library
Electron Beam Charge Diagnostics for Laser Plasma Accelerators (open access)

Electron Beam Charge Diagnostics for Laser Plasma Accelerators

A comprehensive study of charge diagnostics is conducted to verify their validity for measuring electron beams produced by laser plasma accelerators (LPAs). First, a scintillating screen (Lanex) was extensively studied using subnanosecond electron beams from the Advanced Light Source booster synchrotron, at the Lawrence Berkeley National Laboratory. The Lanex was cross calibrated with an integrating current transformer (ICT) for up to the electron energy of 1.5 GeV, and the linear response of the screen was confirmed for charge density and intensity up to 160 pC/mm{sup 2} and 0.4 pC/(ps mm{sup 2}), respectively. After the radio-frequency accelerator based cross calibration, a series of measurements was conducted using electron beams from an LPA. Cross calibrations were carried out using an activation-based measurement that is immune to electromagnetic pulse noise, ICT, and Lanex. The diagnostics agreed within {+-}8%, showing that they all can provide accurate charge measurements for LPAs.
Date: June 27, 2011
Creator: Nakamura, Kei; Gonsalves, Anthony; Lin, Chen; Smith, Alan; Rodgers, David; Donahue, Rich et al.
Object Type: Article
System: The UNT Digital Library
THE FINAL DEMISE OF EAST TENNESSEE TECHNOLOGY PARK BUILDING K-33 Health Physics Society Annual Meeting West Palm Beach, Florida June 27, 2011 (open access)

THE FINAL DEMISE OF EAST TENNESSEE TECHNOLOGY PARK BUILDING K-33 Health Physics Society Annual Meeting West Palm Beach, Florida June 27, 2011

Building K-33 was constructed in 1954 as the final section of the five-stage uranium enrichment cascade at the Oak Ridge Gaseous Diffusion Plant (ORGDP). The two original building (K-25 and K-27) were used to produce weapons grade highly enriched uranium (HEU). Building K-29, K-31, and K-33 were added to produce low enriched uranium (LEU) for nuclear power plant fuel. During ORGDP operations K-33 produced a peak enrichment of 2.5%. Thousands of tons of reactor tails fed into gaseous diffusion plants in the 1950s and early 1960s introducing some fission products and transuranics. Building K-33 was a two-story, 25-meters (82-feet) tall structure with approximately 30 hectare (64 acres) of floor space. The Operations (first) Floor contained offices, change houses, feed vaporization rooms, and auxiliary equipment to support enrichment operations. The Cell (second) Floor contained the enrichment process equipment and was divided into eight process units (designated K-902-1 through K-902-8). Each unit contained ten cells, and each cell contained eight process stages (diffusers) for a total of 640 enrichment stages. 1985: LEU buildings were taken off-line after the anticipated demand for uranium enrichment failed to materialize. 1987: LEU buildings were placed in permanent shutdown. Process equipment were maintained in a shutdown state. …
Date: June 27, 2011
Creator: King, David A.
Object Type: Report
System: The UNT Digital Library
Improving Turn Around Times Of Calorimeter Measurements In The LLNL MC&A Labs Through Reduction Of Thermal Impedance (open access)

Improving Turn Around Times Of Calorimeter Measurements In The LLNL MC&A Labs Through Reduction Of Thermal Impedance

None
Date: June 27, 2011
Creator: Cochran, C. W.; Johnson, R. W. & Sanchez, J. J.
Object Type: Article
System: The UNT Digital Library
INDEPENDENT TECHNICAL ASSESSMENT OF MANAGEMENT OF STORMWATER AND WASTEWATER AT THE SEPARATIONS PROCESS RESEARCH UNIT (SPRU) DISPOSITION PROJECT, NEW YORK (open access)

INDEPENDENT TECHNICAL ASSESSMENT OF MANAGEMENT OF STORMWATER AND WASTEWATER AT THE SEPARATIONS PROCESS RESEARCH UNIT (SPRU) DISPOSITION PROJECT, NEW YORK

The U.S. Department of Energy (DOE) is currently evaluating the water management procedures at the Separations Process Research Unit (SPRU). The facility has three issues related to water management that require technical assistance: (1) due to a excessive rainfall event in October, 2010, contaminated water collected in basements of G2 and H2 buildings. As a result of this event, the contractor has had to collect and dispose of water offsite; (2) The failure of a sump pump at a KAPL outfall resulted in a Notice of Violation issued by the New York State Department of Environment and Conservation (NYSDEC) and subsequent Consent Order. On-site water now requires treatment and off-site disposition; and (3) stormwater infiltration has resulted in Strontium-90 levels discharged to the storm drains that exceed NR standards. The contractor has indicated that water management at SPRU requires major staff resources (at least 50 persons). The purpose of this review is to determine if the contractor's technical approach warrants the large number of staff resources and to ensure that the technical approach is compliant and in accordance with federal, state and NR requirements.
Date: June 27, 2011
Creator: Abitz, R.; Jackson, D. & Eddy-Dilek, C.
Object Type: Report
System: The UNT Digital Library
Majorana One-Tonne Cryostat Cooling Conceptual Feasibility Study Rev 1 (open access)

Majorana One-Tonne Cryostat Cooling Conceptual Feasibility Study Rev 1

This report evaluates the conceptual plans for a cryostat cooling design for the MAJORANA DEMONSTRATOR (MJD) one-tonne (S4) experiment. This document is based upon previous design work and experimental results used to evaluate the current MJD thermal design. A feasibility study of a cooling system for S4 based on the MJD thermosiphon experiment is presented. The one-tonne experiment will be a scaled up version of the MJD. There will be many cryostats in the S4 experiment. In this document a cryostat with up to 19 strings of germanium crystals is analyzed. Aside from an extra outer ring of crystals, the geometry of the cryostat for S4 is very similar to that for the MJD thermosiphon experiment. The materials used in the fabrication of both of these ultra-low background experiments will be underground-electroformed copper. The current MJD uses a two-phase liquid-gas cooling system to provide constant operating temperature. This document presents a theoretical investigation of a cooling system for the S4 experiment and evaluates the heat transfer performance requirements for such a system.
Date: June 27, 2011
Creator: Reid, Douglas J.; Fast, James E.; Orrell, John L. & Aguayo Navarrete, Estanislao
Object Type: Report
System: The UNT Digital Library
On the Computation of Integral Curves in Adaptive Mesh Refinement Vector Fields (open access)

On the Computation of Integral Curves in Adaptive Mesh Refinement Vector Fields

Integral curves, such as streamlines, streaklines, pathlines, and timelines, are an essential tool in the analysis of vector field structures, offering straightforward and intuitive interpretation of visualization results. While such curves have a long-standing tradition in vector field visualization, their application to Adaptive Mesh Refinement (AMR) simulation results poses unique problems. AMR is a highly effective discretization method for a variety of physical simulation problems and has recently been applied to the study of vector fields in flow and magnetohydrodynamic applications. The cell-centered nature of AMR data and discontinuities in the vector field representation arising from AMR level boundaries complicate the application of numerical integration methods to compute integral curves. In this paper, we propose a novel approach to alleviate these problems and show its application to streamline visualization in an AMR model of the magnetic field of the solar system as well as to a simulation of two incompressible viscous vortex rings merging.
Date: June 27, 2011
Creator: Deines, Eduard; Weber, Gunther H.; Garth, Christoph; Van Straalen, Brian; Borovikov, Sergey; Martin, Daniel F. et al.
Object Type: Book
System: The UNT Digital Library
PROCESS KNOWLEDGE DATA GATHERING AND REPORTING IN SUPPORT OF DECOMMISSIONING Health Physics Society Annual Meeting West Palm Beach, Florida June 27, 2011 (open access)

PROCESS KNOWLEDGE DATA GATHERING AND REPORTING IN SUPPORT OF DECOMMISSIONING Health Physics Society Annual Meeting West Palm Beach, Florida June 27, 2011

Summary of recent ORAU decommissioning activities at the Oak Ridge National Laboratory (ORNL) and the East Tennessee Technology Park (ETTP). Project objective was to generate approved Waste Lot Profiles for legacy facilities scheduled for demolition and shipment to the Environmental Management Waste Management Facility (EMWMF) or appropriate alternate facility. The form and content of process knowledge (PK) reports were developed with input from the EMWMF Waste Acceptance Criteria (WAC) Attainment Team and regulators. PK may be defined as the knowledge of the design and the history of operations that occurs during the life cycle of a facility (paraphrased from SRNL guidance) - similar to the MARSSIM historical site assessment. Some types of PK data used to decommission ORNL and ETTP facilities include: (1) Design drawings; (2) Historical documents [e.g., History of the Oak Ridge National Laboratory by Thomas (1963) and A Brief History of the Chemical Technical Division (ORNL/M-2733)]; (3) Historical photographs; (4) Radiological survey reports; (5) Facility-specific databases - (a) Spill history, (b) Waste Information Tracking System (WITS), and (c) Hazardous Materials Management Information System (HMMIS); (6) Facility walkdown summary reports; and (7) Living memory data. Facility walkdowns are critical for worker safety planning and to assure on-the-ground-conditions match …
Date: June 27, 2011
Creator: King, David A.
Object Type: Report
System: The UNT Digital Library
Adaptive Environmentally Contained Power and Cooling IT Infrastructure for the Data Center (open access)

Adaptive Environmentally Contained Power and Cooling IT Infrastructure for the Data Center

The objectives of this program were to research and develop a fully enclosed Information Technology (IT) rack system for 100 kilowatts (KW) of IT load that provides its own internal power and cooling with High Voltage Alternating Current (HVAC defined as 480 volt) and chilled water as the primary inputs into the system and accepts alternative energy power sources such as wind and solar. For maximum efficiency, internal power to the IT equipment uses distributed High Voltage Direct Current power (HVDC defined as 360-380 volt) from the power source to the IT loads. The management scheme aggressively controls energy use to insure the best utilization of available power and cooling resources. The solution incorporates internal active management controls that not only optimizes the system environment for the given dynamic IT loads and changing system conditions, but also interfaces with data center Building Management Systems (BMS) to provide a complete end-to-end view of power and cooling chain. This technology achieves the goal of a Power Usage Effectiveness (PUE) of 1.25, resulting in a 38% reduction in the total amount of energy needed to support a 100KW IT load compared to current data center designs.
Date: June 27, 2012
Creator: Mann, Ron & Chavez, Miguel, E.
Object Type: Report
System: The UNT Digital Library
DECONTAMINATION FACTORS AND FILTRATION FLUX IMPACT TO ARP AT REDUCED MST CONCENTRATION (open access)

DECONTAMINATION FACTORS AND FILTRATION FLUX IMPACT TO ARP AT REDUCED MST CONCENTRATION

Tank Farm and Closure Engineering is evaluating changes to the Actinide Removal Process facility operations to decrease the MST concentration from 0.4 g/L to 0.2 g/L and the contact time from 12 hours to between 6 and 8 hours. For this evaluation, SRNL reviewed previous datasets investigating the performance of MST at 0.2 g/L in salt solutions ranging from 4.5 to 7.5 M in sodium concentration. In general, reducing the MST concentration from 0.4 to 0.2 g/L and increasing the ionic strength from 4.5 to 7.5 M in sodium concentration will decrease the measured decontamination factors for plutonium, neptunium, uranium and strontium. The decontamination factors as well as single standard deviation values for each sorbate are reported. These values are applicable within the sorbate and sodium concentrations used in the experimental measurements. Decreasing the MST concentration in the ARP from 0.4 g/L to 0.2 g/L will produce an increase in the filter flux, and could lead to longer operating times between filter cleaning. The increase in flux is a function of a number of operating parameters, and is difficult to quantify. However, it is estimated that the reduction in MST could result in a reduction of filtration time of up …
Date: June 27, 2012
Creator: Hobbs, D.
Object Type: Report
System: The UNT Digital Library
Distinct Effects of Reduced Sulfur Compounds on Pd-catalytic Hydrodechlorination of TCE in Groundwater Using Cathodic H2 under Electrochemically-induced Oxidizing Conditions (open access)

Distinct Effects of Reduced Sulfur Compounds on Pd-catalytic Hydrodechlorination of TCE in Groundwater Using Cathodic H2 under Electrochemically-induced Oxidizing Conditions

None
Date: June 27, 2012
Creator: Yuan, S.; Chen, M.; Mao, X. & Alshawabkeh, A. N.
Object Type: Article
System: The UNT Digital Library
Fabrication and testing of germanium grisms for LMIRcam (open access)

Fabrication and testing of germanium grisms for LMIRcam

None
Date: June 27, 2012
Creator: Kuzmenko, P J; Little, S L; Little, L M; Wilson, J C; Skrutskie, M F; Hinz, P M et al.
Object Type: Article
System: The UNT Digital Library
HYDRAULIC CONDUCTIVITY OF SALTSTONE FORMULATED USING 1Q11, 2Q11 AND 3Q11 TANK 50 SLURRY SAMPLES (open access)

HYDRAULIC CONDUCTIVITY OF SALTSTONE FORMULATED USING 1Q11, 2Q11 AND 3Q11 TANK 50 SLURRY SAMPLES

As part of the Saltstone formulation work requested by Waste Solidification Engineering (WSE), Savannah River National Laboratory (SRNL) was tasked with preparing Saltstone samples for fresh property analysis and hydraulic conductivity measurements using actual Tank 50 salt solution rather than simulated salt solution. Samples of low level waste salt solution collected from Tank 50H during the first, second, and third quarters of 2011 were used to formulate the Saltstone samples. The salt solution was mixed with premix (45 wt % slag, 45 wt % fly ash, and 10 wt % cement), in a ratio consistent with facility operating conditions during the quarter of interest. The fresh properties (gel, set, bleed) of each mix were evaluated and compared to the recommended acceptance criteria for the Saltstone Production Facility. ASTM D5084-03, Method C was used to measure the hydraulic conductivity of the Saltstone samples. The hydraulic conductivity of Saltstone samples prepared from 1Q11 and 2Q11 samples of Tank 50H is 4.2E-9 cm/sec and 2.6E-9 cm/sec, respectively. Two additional 2Q11 and one 3Q11 sample were not successfully tested due to the inability to achieve stable readings during saturation and testing. The hydraulic conductivity of the samples made from Tank 50H salt solution compare …
Date: June 27, 2012
Creator: Reigel, M. & Nichols, R.
Object Type: Report
System: The UNT Digital Library
Hydrogen Selective Inorganic membranes for Gas Separations under High Pressure Intermediate Temperature Hydrocarbonic Envrionment (open access)

Hydrogen Selective Inorganic membranes for Gas Separations under High Pressure Intermediate Temperature Hydrocarbonic Envrionment

In this project, we have successfully developed a full scale commercially ready carbon molecular sieve (CMS) based membrane for applications in H{sub 2} recovery from refinery waste and other aggressive gas streams. Field tests at a refinery pilot plant and a coal gasification facility have successfully demonstrated its ability to recovery hydrogen from hydrotreating and raw syngas respectively. High purity H{sub 2} and excellent stability of the membrane permeance and selectivity were obtained in testing conducted over >500 hours at each site. The results from these field tests as well as laboratory testing conclude that the membranes can be operated at high pressures (up to 1,000 psig) and temperatures (up to 300 C) in presence of aggressive contaminants, such as sulfur and nitrogen containing species (H{sub 2}S, CO{sub 2}, NH{sub 3}, etc), condensable hydrocarbons, tar-like species, heavy metals, etc. with no observable effect on membrane performance. By comparison, similar operating conditions and/or environments would rapidly destroy competing membranes, such as polymeric, palladium, zeolitic, etc. Significant cost savings can be achieved through recovering H{sub 2} from refinery waste gas using this newly developed CMS membrane. Annual savings of $2 to 4MM/year (per 20,000 scfd of waste gas) can be realized by …
Date: June 27, 2012
Creator: Ciora, Rich & Liu, Paul K. T.
Object Type: Report
System: The UNT Digital Library
LLNL NESHAPs 2011 Annual Report - June 2012 (open access)

LLNL NESHAPs 2011 Annual Report - June 2012

None
Date: June 27, 2012
Creator: Wilson, K R; Bertoldo, N A; Gallegos, G M; MacQueen, D M & Wegrecki, A M
Object Type: Report
System: The UNT Digital Library
A Mixed Formulation for the Brinkman Problem (open access)

A Mixed Formulation for the Brinkman Problem

None
Date: June 27, 2012
Creator: Vassilevski, P S & Villa, U
Object Type: Article
System: The UNT Digital Library
Final Report - Investigation of Intermittent Turbulence and Turbulent Structures in the Presence of Controlled Sheared Flows (open access)

Final Report - Investigation of Intermittent Turbulence and Turbulent Structures in the Presence of Controlled Sheared Flows

Final Report for grant DE-FG02-06ER54898. The dynamics and generation of intermittent plasma turbulent structures, widely known as "blobs" have been studied in the presence of sheared plasma flows in a controlled laboratory experiment.
Date: June 27, 2013
Creator: Gilmore, Mark A.
Object Type: Report
System: The UNT Digital Library