Evaluation of plasma-sprayed pyrolytic graphite components (open access)

Evaluation of plasma-sprayed pyrolytic graphite components

None
Date: January 10, 1964
Creator: Goodspeed, R.C.
System: The UNT Digital Library
Residual Stresses in Extruded Graphite Tubes (open access)

Residual Stresses in Extruded Graphite Tubes

None
Date: January 10, 1964
Creator: Price, R. J.
System: The UNT Digital Library
PATHFINDER ATOMIC POWER PLANT. RECIRCULATION PIPING DESIGN (open access)

PATHFINDER ATOMIC POWER PLANT. RECIRCULATION PIPING DESIGN

The coolant recirculation system in the Pathfinder reactor comprises three mixed-flow centrifugal pumps and three piping loops. The design criteria are summarized; and flexibility and stress analyses on the piping are presented, together with a vibration analysis of one pump and loop. The results indicate that vibration should be no problem, that all stresses are within the allowable limits, and that there should be no resonance difficulties during pump operation. (D.C.W.)
Date: January 10, 1964
Creator: Nolan, D. J. & Patterson, J. F.
System: The UNT Digital Library
DEMONSTRATION DISPOSAL OF HIGH-LEVEL RADIOACTIVE SOLIDS IN LYONS, KANSAS, SALT MINE: BACKGROUND AND PRELIMINARY DESIGN OF EXPERIMENTAL ASPECTS (open access)

DEMONSTRATION DISPOSAL OF HIGH-LEVEL RADIOACTIVE SOLIDS IN LYONS, KANSAS, SALT MINE: BACKGROUND AND PRELIMINARY DESIGN OF EXPERIMENTAL ASPECTS

A demonstration of the disposal of high-level radioactive waste solids to be carried out in a salt mine at Lyons, Kansas, will have as its objectives: (1) the demonstration of required waste-handling equipment and techniques, (2) the determination of the stability of salt under the influence of heat and radiation, and (3) the collection of information on creep and plastic flow of salt which is needed for the design of an actual disposal facility. As presently conceived, 14 irradiated fuel assemblies from the Engineering Test Reactor will serve as a source of radiation in lieu of actual solidified wastes. The assemblies will be placed in a circular array of holes in the floor with one can in the center and other six cans located peripherally, spaced 5 ft on centers. During the course of the 2-year test, four sets of assemblies will be used to achieve a peak dose to the salt of about 8 x 10/sup 8/ rad and the temperature of the adjacent salt will be maintained at 200 deg C with electrical heaters. A second array, consisting only of heaters, will be operated as a control to determine those effects due solely to heat. In addition to …
Date: January 10, 1964
Creator: Bradshaw, R. L.; Perona, J. J. & Blomeke, J. O.
System: The UNT Digital Library