Hazards Summary Report for the SM-1 Core Temperature and Flow Instrumentation: Task XIV (open access)

Hazards Summary Report for the SM-1 Core Temperature and Flow Instrumentation: Task XIV

Abstract; This technical report describes the changes in the SM-1 incurred by the experiment, Core Temperature and Flow Instrumentation (Task XIV), and evaluates the possible hazard involved in these changes. Temperature and flow measurements will be taken on a Task XIV instrumented stationary fuel element, instrumented control rod fuel element and other selected points in the SM-1 core to provide data on the core steady state and transient performance. The hazards evaluation consists of a nuclear evaluation, thermal and hydraulic analysis, description of tests to be performed, and discussion of containment integrity and maximum accident considerations.
Date: March 30, 1961
Creator: Coombe, J. R.; Brondel, J. O.; Lee, D. H. & Matthews, F. T.
System: The UNT Digital Library
Hazards Report for the SM-1 Core II With Special Components (open access)

Hazards Report for the SM-1 Core II With Special Components

Abstract: This technical report describes the changes incurred in the SM-1 by the insertion of the SM-1 Core II and special components. The special components consist of impact specimens, a boron gradient rod, SM-2 elements, a PM-1-M element, and high burnup SM-1 Core I elements. The change in hazards, due to operation of SM-1 with Core II and the special components is evaluated. The analysis indicates there is no change in hazards.
Date: March 30, 1961
Creator: Coombe, J.; Lee, D.; Segalman, I. & Robertson, R.
System: The UNT Digital Library
Extended SM-2 Critical Experiments : CE-2 (open access)

Extended SM-2 Critical Experiments : CE-2

Abstract: This technical report contains a description and results of a second series of critical experiments performed on the SM-2 core mock-up, as additional to the first series of experiments reported in APAE No. 54. The SM-2 core mock-up contains 36.4 kg U-235 and and estimated 67.9 gm B-10. The equivalent diameter and the active height are about 22 in.; the metal-to-water volume ration is 0.344. Data is presented on activation, reactivity, and stuck rod measurements. All measurements were conducted on the open seven control rod array employing 38 stationary fuel elements. Activation measurements consisted of neutron flux measurements using uranium fission foils for relative power distribution studies, the effect of flux suppressors on reducing power peaks, blocked coolant channel measurements, and gamma ray dose distribution. Reactivity measurements were performed to determine the effect f flow divider, flux suppressors and stimulated high temperature and pressure operation; b-10 loading in the SM-2 core; and core material coefficients. For the later, the worth in cents per gm or cents per cc was determined at simulated temperature of 510 degree F for B-10, U-235, stainless steel, and void. Stuck rod measurements were made to obtain an indication of the criticality margin in the …
Date: June 30, 1961
Creator: McCool, W. J.; Robinson, R. A.; Weiss, S. H.; Raby, T. M.; Schrader, E. W. & Walthousen, L. D.
System: The UNT Digital Library
SM-2 Full Scale Flow Studies Termination Report (open access)

SM-2 Full Scale Flow Studies Termination Report

Abstract: Hydrodynamic flow studies were conducted on a full scale model of the SM-2 reactor vessel and core. Test fluid was water at 200 psi and 200 degree F. Test facilities, model, and instrumentation design are discussed. Flow distribution in the stationary fuel elements, lattices, and control rods of the second pass was investigated. Pressure losses through the various core components were measured and are compared with calculated values. Observed over-all pressure drop was 71 feet of water at 200 degree F, 31% higher than predicted, part of which was due to presence of instrument leads. Element to element flow distribution varied approximately +-8% from pass average. Channel-to-channel stationary element flow distribution varied approximately +-10% from element average and control rod flow distribution varied from +-8.9% to +-6.4 and -11.6% depending upon rod locations. These variations exceed the original goals of a +-10% and +-12% combined deviation for stationary and control rod elements respectively, but are satisfactory in relation to thermal design. There was no indication of unsatisfactory structural performance of any components under hydrodynamic loadings up to 130% of design values. The test program was terminated after determining flow distribution in the reference core design, omitting any work on …
Date: July 30, 1961
Creator: Christenson, J. A.; Richards, W. M. S. & Davidson, S. L.
System: The UNT Digital Library