1A Reactor Inlet Hydraulic Valve Position Detector Temperature. Section I. Core I, Seed 1. Test Results DL-S-258-S, RNI-3 (open access)

1A Reactor Inlet Hydraulic Valve Position Detector Temperature. Section I. Core I, Seed 1. Test Results DL-S-258-S, RNI-3

The purpose of the test was to determine the internal temperature of the valve position detector for the 1A reactor inlet hydraulic valve with the plant at normal pressure and temperature and at power. The normal operating temperatures for the valve position detector on the 1A reactor inlet hydraulic valve range from a minimum of 287 F to a maximum of 294.7 F.
Date: November 20, 1959