Increasing Thermocouple Reliability for in-Pile Experiments (open access)

Increasing Thermocouple Reliability for in-Pile Experiments

Abstract: The results indicated that increased reliability can be obtained by using thermocouples made with insulation of increased density and/or a low thermal expansion sheath.
Date: April 20, 1965
Creator: Babbe, E. L.
System: The UNT Digital Library
SRE Mark II Fuel Handling Machine (open access)

SRE Mark II Fuel Handling Machine

Abstract: The Sodium Reactor Experiment Mark II Fuel Handling Machine has been modified to ensure fuel and gas containment during core III operation. A new fuel control system has been designed for the fuel handling machine.
Date: April 20, 1965
Creator: Dietz, H. B.
System: The UNT Digital Library
Crystal Structure Of B 'Cu0.75Al0.25 (open access)

Crystal Structure Of B 'Cu0.75Al0.25

The problem of crystal structure of the martensitic B1 phase of the eutectic alloy in the Cu-Al system still requires a more accurate clarification (Hun ger and Dienst 1960, Tarora 1949). Martensitic phases in general are formed through small thrust (shear) deformations of the original lattice. On this basis the results of Hunger and Dienst (1960) are doubtful, since the lattice constants found by them have required a considerable reclassification. From the known lattice constants of the B1 phase (Tarora, 1949) and the orientation relationships of the B1 phase (Wassermann, 1934) one has expected a hexagonal lattice for the martensitic phase with [formula].
Date: April 20, 1962
Creator: Thomas, G. & Huffstutler, M.C., Jr.
System: The UNT Digital Library
Cesium-137 Research Irradiator (open access)

Cesium-137 Research Irradiator

Abstract: A 12,000 curie cesium-137 research irradiator has been designed and installed on the Georgia Tech campus. The evaluation of the physical characteristics of the irradiator has been completed.
Date: April 20, 1961
Creator: Carter, R. W.; Palmer, R. C. & Willis, W. V.
System: The UNT Digital Library
Transistor Pre-Amplifier for Neutron Monitors (open access)

Transistor Pre-Amplifier for Neutron Monitors

In the past several years the use of neutron monitors for Pu concentration monitoring has been expanded in the Chemical Processing Department. Most of these monitors have been quite successful, and considerable effort is being made to improve the operation of both existing and future monitoring systems. One of the major improvements has been the development and use of a transistorized pre-amplifier or impedance matching circuits. This unit solves several problems associated with the use of boron trifluoride (BF3) neutron detectors in process monitoring; e.g., vacuum tube pre-amp failure because heat is not being conducted away.
Date: April 20, 1960
Creator: Kelly, P. R.
System: The UNT Digital Library