Sea Water Corrosion Test Program (open access)

Sea Water Corrosion Test Program

From Introduction: "The first demonstration plant sponsored by the Office of Saline Water was located in Freeport, Texas, and came 'on stream" in 1961. The incoming sea water was deaerated since both Speller (6) and Uhlig (7) recognized that dissolved oxygen was usually the controlling factor in the corrosion of iron stream condensate at temperatures even as high 400 degrees F. The water was acidified prior to daeration with H2SO4 to decompose the carbonates which subsequently would cause scale when the water was heated. After the carbonates were removed, the pH was raised to the neutral point, again to provide a less corrosive environment."
Date: March 1969
Creator: Behrens, H. C.; Martin, F. D.; Osborn, O.; Rice, L.; Russell, W. B.; Schreiber, C. F. et al.
System: The UNT Digital Library
Secondary Refrigerant Freezing Desalting Process: Operation of a 15,000 GPD Pilot Plant (open access)

Secondary Refrigerant Freezing Desalting Process: Operation of a 15,000 GPD Pilot Plant

Report issued by the Office of Saline Water over the development of the secondary refrigerant freeze desalination process. The process is presented and discussed. This report includes tables, illustrations, and photographs.
Date: March 1969
Creator: Ganiaris, N.; Lambiris, J.; Glasser, R.; Hunter, J. A.; Rinne, W. W. & Verikios, S. C.
System: The UNT Digital Library