Reactor Analysis for the Army Package Power Reactor No. 1 (open access)

Reactor Analysis for the Army Package Power Reactor No. 1

Abstract: The reactor analysis of the critical experiment and the APPR-1 resulted in a loading of the APPR-1 of 31.096 gm of B-10 with 22.5 kg U-335. This loading will result in adequate reactivity for a core life of 13 MWYR based on uniform burnup of U-335 and B-10. Calculations indicate that five of the seven control rods provided are more than adequate to shut the reactor down at any time. The temperature coefficient of reactivity should be at least -2 x 10-4 [delta] K/0F.
Date: May 29, 1956
Creator: Gallagher, J. G.; Giesler, H. W.; Johnson, W. R.; Fairbanks, F. B.; Oby, P. V. & Crouch, A. N.
System: The UNT Digital Library
Reactor Analysis for the Army Package Power Reactor No. 1 (open access)

Reactor Analysis for the Army Package Power Reactor No. 1

Abstract: The reactor analysis of the critical experiment and the APPR-1 resulted in a loading of the APPR-1 of 31.096 gm of B-10 with 22.5 kg U-335. This loading will result in adequate reactivity for a core life of 13 MWYR based on uniform burnup of U-335 and B-10. Calculations indicate that five of the seven control rods provided are more than adequate to shut the reactor down at any time. The temperature coefficient of reactivity should be at least -2 x 10-4 [delta] K/0F.
Date: May 29, 1956
Creator: Gallagher, J. G.; Giesler, H. W.; Johnson, W. R.; Fairbanks, F. B.; Oby, P. V. & Crouch, A. N.
System: The UNT Digital Library