First order leveling to be conducted as part of an environmental monitoring program for a geopressured test well was reported. 39.43 kilometers of first order levels were run to NGS specifications. Twelve Class B type bench marks were set to NGS specifications. The adjusted elevation of bench mark C-1209 was used as a starting elevation and is based on a supplementary adjustment of April 6, 1979 by NGS. The closure for the loop around the well site is -0.65 millimeters. The distance around the loop is 1.29 kilometers, the allowable error of closure was 4.54 millimeters. The initial leveling of this well was performed in 1977. A thorough search for their monumentation was conducted. No monuments were found due to the lack of adequate monument descriptions. Therefore, an elevation comparison summary for this report is only available along the NGS lines outside the well area. The first order level tie to line No. 101 (BMA-1208) was +3.37 millimeters in 17.21 kilometers. The allowable error of closure was 12.44 millimeters.