183 Matching Results

Results open in a new window/tab.

High Multiplicity Searches at the LHC Using Jet Masses (open access)

High Multiplicity Searches at the LHC Using Jet Masses

This article introduces a new class of searches for physics beyond the Standard Model that improves the sensitivity to signals with high jet multiplicity. The proposed searches gain access to high multiplicity signals by reclustering events into large-radius, or 'fat', jets and by requiring that each event has multiple massive jets. This technique is applied to supersymmetric scenarios in which gluinos are pair-produced and then subsequently decay to final states with either moderate quantities of missing energy or final states without missing energy. In each of these scenarios, the use of jet mass improves the estimated reach in gluino mass by 20% to 50% over current LHC searches.
Date: April 24, 2012
Creator: Hook, Anson; /SLAC /Stanford U., Appl. Phys. Dept.; Izaguirre, Eder; /SLAC /Stanford U., Phys. Dept.; Lisanti, Mariangela; U., /Princeton et al.
System: The UNT Digital Library
PEP-II Status and Outlook (open access)

PEP-II Status and Outlook

PEP-II/BABAR are presently in their second physics run. With machine and detector performance and reliability at an all-time high, almost 51 fb{sup -1} have been integrated by BABAR up to mid-October 2001. PEP-II luminosity has reached 4.4 x 10{sup 33} cm{sup -2} s{sup -1} and our highest monthly delivered luminosity has been above 6 pb{sup -1}, exceeding the performance parameters given in the PEP-II CDR by almost 50%. The increase compared to the first run in 2000 has been achieved by a combination of beam-current increase and beam-size decrease. In this paper we will summarize the PEP-II performance and the present limitations as well as our plans to further increase machine performance.
Date: April 24, 2012
Creator: Wienands, H. U.; Biagini, M. E.; Decker, F. J.; Donald, M. H.; Ecklund, S.; Fisher, A. et al.
System: The UNT Digital Library
Searches for Leptonic B Decays at BaBar (open access)

Searches for Leptonic B Decays at BaBar

Measurements of the branching fractions of purely leptonic decays of B-mesons translate into constraints in the plane of the charged Higgs mass versus tan {beta} which are relatively insensitive to the particular theoretical model. Using the full BABAR dataset of 450 million B-decays we search for these decays. No significant signal is found in the decays into electrons or muons and we set upper limits on the branching fractions of the order of a 10{sup -6} at 90% confidence level. We measure the branching fraction of B {yields} {tau}{mu} to be (1.7 {+-} 0.6) x 10{sup -4}.
Date: April 25, 2012
Creator: Nelson, Silke
System: The UNT Digital Library
Beyond Mean-Field Calculation For Pairing Correlation (open access)

Beyond Mean-Field Calculation For Pairing Correlation

None
Date: April 26, 2012
Creator: Hupin, G & Lacroix, D
System: The UNT Digital Library
From self-organized to extended criticality (open access)

From self-organized to extended criticality

Article discussing the criticality of transition processes in neurophysiology.
Date: April 26, 2012
Creator: Lovecchio, Elisa; Allegrini, Paolo; Geneston, Elvis L.; West, Bruce J. & Grigolini, Paolo
System: The UNT Digital Library
General Relativistic Magnetohydrodynamic Simulations of Magnetically Choked Accretion Flows around Black Holes (open access)

General Relativistic Magnetohydrodynamic Simulations of Magnetically Choked Accretion Flows around Black Holes

Black hole (BH) accretion flows and jets are qualitatively affected by the presence of ordered magnetic fields. We study fully three-dimensional global general relativistic magnetohydrodynamic (MHD) simulations of radially extended and thick (height H to cylindrical radius R ratio of |H/R| {approx} 0.2-1) accretion flows around BHs with various dimensionless spins (a/M, with BH mass M) and with initially toroidally-dominated ({phi}-directed) and poloidally-dominated (R-z directed) magnetic fields. Firstly, for toroidal field models and BHs with high enough |a/M|, coherent large-scale (i.e. >> H) dipolar poloidal magnetic flux patches emerge, thread the BH, and generate transient relativistic jets. Secondly, for poloidal field models, poloidal magnetic flux readily accretes through the disk from large radii and builds-up to a natural saturation point near the BH. While models with |H/R| {approx} 1 and |a/M| {le} 0.5 do not launch jets due to quenching by mass infall, for sufficiently high |a/M| or low |H/R| the polar magnetic field compresses the inflow into a geometrically thin highly non-axisymmetric 'magnetically choked accretion flow' (MCAF) within which the standard linear magneto-rotational instability is suppressed. The condition of a highly-magnetized state over most of the horizon is optimal for the Blandford-Znajek mechanism that generates persistent relativistic jets with …
Date: April 26, 2012
Creator: McKinney, Jonathan C.; Tchekhovskoy, Alexander & Blandford, Roger D.
System: The UNT Digital Library
Integrated X-Ray Reflectivity Measurements for Elliptically Curved PET Crystals (open access)

Integrated X-Ray Reflectivity Measurements for Elliptically Curved PET Crystals

Spectroscopy provides valuable information about the temperature and density of a compressed pellet in a plasma. Elliptically curved pentaerythritol (PET) crystals are used as components for spectrometers. Their elliptical geometry gives several advantages related to spectral energy range, source focus, and spectral image compression.[1] The crystal curvature increases the spectrometer throughput but at the cost of a loss in resolution. Four different crystals are used in a spectrometer at the National Ignition Facility (NIF) target chamber at Lawrence Livermore National Laboratory (LLNL). Figure 1 shows the arrangement of the elliptical PET crystals in the snout of a NIF target diagnostic shown in Figure 2. The spectrum from the crystals is captured by four image plates located behind the crystals. A typical mandrel, the darkened section, upon which the PET crystal is glued, is shown in Figure 3, which also shows the complete ellipse. There are four elliptical segment types, each having the same major axis but a different minor axis. The crystals are 150 mm long in the diffraction direction and 25.4 mm high. Two crystals of each type were calibrated. The throughput for each spectrometer is determined by the integrated reflectivity of the PET crystal.[1] The goal of this …
Date: April 26, 2012
Creator: Haugh, M. J.; Ross, P. W.; Regan, P. W.; Magoon, J.; Shoup, M. J.; Barrios, M. A. et al.
System: The UNT Digital Library
Modeling Responses of Naturally Fractured Geothermal Reservoir to Low-Pressure Stimulation (open access)

Modeling Responses of Naturally Fractured Geothermal Reservoir to Low-Pressure Stimulation

None
Date: April 27, 2012
Creator: Fu, P & Carrigan, C R
System: The UNT Digital Library
An arbuscular mycorrhizal fungus modifies the soil microbial community and nitrogen cycling during litter decomposition (open access)

An arbuscular mycorrhizal fungus modifies the soil microbial community and nitrogen cycling during litter decomposition

None
Date: April 30, 2012
Creator: Nuccio, E E; Hodge, A; Pett-Ridge, J; Herman, D J; Weber, P & Firestone, M K
System: The UNT Digital Library
Ceramic HEPA Filter Program (open access)

Ceramic HEPA Filter Program

Potential benefits of ceramic filters in nuclear facilities: (1) Short term benefit for DOE, NRC, and industry - (a) CalPoly HTTU provides unique testing capability to answer questions for DOE - High temperature testing of materials, components, filter, (b) Several DNFSB correspondences and presentations by DNFSB members have highlighted the need for HEPA filter R and D - DNFSB Recommendation 2009-2 highlighted a nuclear facility response to an evaluation basis earthquake followed by a fire (aka shake-n-bake) and CalPoly has capability for a shake-n-bake test; (2) Intermediate term benefit for DOE and industry - (a) Filtration for specialty applications, e.g., explosive applications at Nevada, (b) Spin-off technologies applicable to other commercial industries; and (3) Long term benefit for DOE, NRC, and industry - (a) Across industry, strong desire for better performance filter, (b) Engineering solution to safety problem will improve facility safety and decrease dependence on associated support systems, (c) Large potential life-cycle cost savings, and (d) Facilitates development and deployment of LLNL process innovations to allow continuous ventilation system operation during a fire.
Date: April 30, 2012
Creator: Mitchell, M A; Bergman, W; Haslam, J; Brown, E P; Sawyer, S; Beaulieu, R et al.
System: The UNT Digital Library
DIXI (Dilation x-ray imager) a new/faster gated x-ray imager for the NIF (open access)

DIXI (Dilation x-ray imager) a new/faster gated x-ray imager for the NIF

None
Date: April 30, 2012
Creator: Nagel, S. R.; Hilsabeck, T. J.; Bell, P. M.; Bradley, D. K.; Ayers, M. J.; Barrios, M. A. et al.
System: The UNT Digital Library
Efficient and Scalable Retrieval Techniques for Global File Properties (open access)

Efficient and Scalable Retrieval Techniques for Global File Properties

None
Date: April 30, 2012
Creator: Ahn, D H; Brim, M; de Supinski, B R; Gamblin, T; Lee, G L; LeGendre, M P et al.
System: The UNT Digital Library
High Bandwidth Differential Amplifier for Shock Experiments (open access)

High Bandwidth Differential Amplifier for Shock Experiments

We developed a high bandwidth differential amplifier for gas gun shock experiments/applications. The circuit has a bandwidth > 1 GHz, and is capable of measuring signals of ≤1.5 V with a common mode rejection of 250 V. Conductivity measurements of gas gun targets are measured by flowing high currents through the targets. The voltage is measured across the target using a technique similar to a four-point probe. Because of the design of the current source and load, the target voltage is approximately 250 V relative to ground. Since the expected voltage change in the target is < 1 V, the differential amplifier must have a large common mode rejection. High pass filters suppress internal ringing of operational amplifiers. Results of bench tests are shown.
Date: April 30, 2012
Creator: Ross, P. W., Tran, V., Chau, R.
System: The UNT Digital Library
Investigating the effects of proton exchange membrane fuel cell conditions on carbon supported platinum electrocatalyst composition and performance (open access)

Investigating the effects of proton exchange membrane fuel cell conditions on carbon supported platinum electrocatalyst composition and performance

Changes that carbon-supported platinum electrocatalysts undergo in a proton exchange membrane fuel cell environment were simulated by ex situ heat treatment of catalyst powder samples at 150 C and 100% relative humidity. In order to study modifications that are introduced to chemistry, morphology, and performance of electrocatalysts, XPS, HREELS and three-electrode rotating disk electrode experiments were performed. Before heat treatment, graphitic content varied by 20% among samples with different types of carbon supports, with distinct differences between bulk and surface compositions within each sample. Following the aging protocol, the bulk and surface chemistry of the samples were similar, with graphite content increasing or remaining constant and Pt-carbide decreasing for all samples. From the correlation of changes in chemical composition and losses in performance of the electrocatalysts, we conclude that relative distribution of Pt particles on graphitic and amorphous carbon is as important for electrocatalytic activity as the absolute amount of graphitic carbon present
Date: April 30, 2012
Creator: Patel, A.; Artyushkova, K.; Atanassov, P.; Colbow, V.; Dutta, M.; Harvey, D. et al.
System: The UNT Digital Library
Soft x-ray images of the Laser Entrance Hole of NIC Hohlraums (paper, HTPD2012) (open access)

Soft x-ray images of the Laser Entrance Hole of NIC Hohlraums (paper, HTPD2012)

Hohlraums at the National Ignition Facility convert laser energy into a thermal x-radiation drive, which implodes the capsule, thus compressing the fuel. The x-radiation drive is measured with a low resolution, time-resolved x-ray spectrometer that views the hohlraum's laser entrance hole (LEH) at 37{sup o} to the hohlraum axis. This measurement has no spatial resolution. To convert this to the drive inside the hohlraum, the area and fraction of the measured x-radiation which comes from the region inside the hohlraum must be known. The size of the LEH is measured with the time integrated Static X-ray Imager (SXI) which view the LEH at 18{sup o} to the hohlraum axis. A soft x-ray image has been added to the SXI to measure the fraction of x-radiation inside the LEH's Clear Aperture in order to correct the measured radiation. A multilayer mirror plus filter selects an x-ray band centered at 870 eV, near the x-ray energy peak of a 300 eV blackbody. Results from this channel and corrections to the x-radiation drive are discussed.
Date: April 30, 2012
Creator: Schneider, M. B. & Meezan, N. B.
System: The UNT Digital Library